DTC P0A94-589 DC / DC Converter Performance |
DTC P0A94-590 DC / DC Converter Performance |

| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A94 | 589 | Open or GND short in boost converter voltage (VL) sensor circuit |
|
| P0A94 | 590 | +B short in boost converter voltage (VL) sensor circuit |
|
| Voltage Displayed | Malfunction |
| 510 V | +B short circuit |
| 0 V | Open or GND short circuit |
| Related DTCs | P0A94 (INF 589 / 590): Boost converter / VL malfunction |
| Required sensor / components | Boost converter |
| Frequency of operation | Continuous |
| Duration | TOYOTA's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TOYOTA's intellectual property |
| Other conditions belong to TOYOTA's intellectual property | - |
| Boost converter voltage sensor circuit | Short |
| Boost converter | DTC P0A94 (INF 589 / 590) is not detected |

| 1.READ VALUE OF THE TECHSTREAM (VL-VOLTAGE BEFORE BOOSTING) |
Connect the Techstream to the DLC3.
Turn the power switch ON (IG).
Enter the following menus: Powertrain / Engine Control / Data List.
Read the "VL-Voltage before Boosting" value.
| Voltage Displayed | Proceed to |
| 510 V | A |
| 0 V | B |
| 1 to 509 V | C |
|
| ||||
|
| ||||
| A | |
| 2.READ VALUE OF THE TECHSTREAM (CHECK FOR +B SHORT IN WIRE HARNESS) |
Turn the power switch OFF.
Remove the service plug grip .
Remove the inverter cover .
![]() |
Disconnect the I10 inverter connector.
![]() |
Turn the power switch ON (IG).
Enter the following menus: Powertrain / Engine Control / Data List.
Read the "VL-Voltage before Boosting" value.
Turn the power switch OFF.
Reconnect the inverter connector.
Reinstall the inverter cover .
Reinstall the service plug grip .
|
| ||||
| NG | |
| 3.READ VALUE OF THE TECHSTREAM (CHECK FOR +B SHORT IN HYBRID VEHICLE CONTROL ECU) |
![]() |
Disconnect the H16 HV control ECU connector.
![]() |
Turn the power switch ON (IG).
Enter the following menus: Powertrain / Engine Control / Data List.
Read the "VL-Voltage before Boosting" value.
Reconnect the HV control ECU connector.
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - INVERTER) |
Turn the power switch OFF.
Remove the service plug grip .
Remove the inverter cover .
![]() |
Disconnect the H16 HV control ECU connector.
![]() |
Disconnect the I10 inverter connector.
Measure the resistance between the wire harness side connectors.
| Tester Connection | Specified Condition |
| VL (H16-30) - VL (I10-15) | Below 1 Ω |
| GCNV (H16-8) - GCNV (I10-32) | Below 1 Ω |
| Tester Connection | Specified Condition |
| VL (H16-30) or VL (I10-15) - Body ground | 10 kΩ or higher |
| GCNV (H16-8) or GCNV (I10-32) - Body ground | 10 kΩ or higher |
Reconnect the inverter connector.
Reconnect the HV control ECU connector.
Reinstall the inverter cover .
Reinstall the service plug grip .
|
| ||||
| OK | |
| 5.CHECK HYBRID VEHICLE CONTROL ECU (VL VOLTAGE) |
![]() |
Turn the power switch ON (READY).
Measure the voltage between the terminals of the H16 HV control ECU connector.
| Tester Connection | Specified Condition |
| VL (H16-30) - GCNV (H16-8) | 1.9 to 3.4 V |
|
| ||||
| OK | ||
| ||