Home › HYBRID SYSTEM › P112 HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P3222-313    Generator Inverter Temperature Sensor Circuit High / Low

DTC    P3223-312    Generator Inverter Temperature Sensor Circuit High

for Preparation Click here


DESCRIPTION

The HV control ECU uses a temperature sensor, which is built into the inverter, to detect the temperature of the generator inverter. The same cooling system that is routed to the MG1 and MG2 cools the inverter. This cooling system is independent from the engine cooling system.
The characteristic of the generator inverter temperature sensor is the same as the boost converter temperature sensor .
The HV control ECU limits the load based on the signals transmitted by the generator inverter temperature sensor, in order to check the effectiveness of the inverter cooling system and prevent the inverter from overheating. Furthermore, the HV control ECU detects a malfunction in the wiring of the generator inverter temperature sensor, as well as in the sensor itself.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P3222
313
Open or GND short in generator inverter temperature sensor circuit
  1. Wire harness or connector
  2. Inverter with converter assembly
  3. HV control ECU
P3223
312
+B short in generator inverter temperature sensor circuit
  1. Wire harness or connector
  2. Inverter with converter assembly
  3. HV control ECU

HINT:
After confirming DTC P3222 (INF 313) or P3223 (INF 312), confirm Inverter Temp-(MG1) in DIAGNOSIS / OBD/MOBD / HV ECU / DATA LIST using the Techstream.


Temperature Displayed
Malfunction
-58°F (-50°C)
+B short circuit
401°F (205°C)
Open or GND short circuit

WIRING DIAGRAM


A092100E04


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are servicing the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.

HINT:
At least 5 minutes are required to discharge the high-voltage condenser inside the inverter.

1.READ VALUE OF THE TECHSTREAM (INVERTER TEMP-(MG1))
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch ON (IG).

  1. Enter the following menus: Powertrain / Engine Control / Data List.

  1. Read the "Inverter Temp-(MG1)" value.

    Result:

    Temperature Displayed
    Proceed to
    -58°F (-50°C)
    A
    401°F (205°C)
    B
    -57°F to 400°F (-49°C to 204°C)
    C

    HINT:
    1. If there is a +B short circuit, the Techstream indicates -58°F (-50°C).
    2. If there is an open or GND short circuit, the Techstream indicates 401°F (205°C).



B
Go to step 4

C
CHECK FOR INTERMITTENT PROBLEMS
A


2.READ VALUE OF THE TECHSTREAM (CHECK FOR +B SHORT IN WIRE HARNESS)

CAUTION:
Wear insulated gloves before performing the following operation.

  1. Turn the power switch OFF.

  1. Remove the service plug grip .

    NOTICE:
    Turning the power switch ON (READY) with the service plug grip removed could cause malfunction. Therefore, never turn the power switch ON (READY) in this state.

  1. Remove the inverter cover .



    A092041E33
  1. Disconnect the I10 inverter connector.



    A125426E05
  1. Turn the power switch ON (IG).

    HINT:
    DTCs for the interlock switch system are output when turning the power switch ON (IG) with both service plug grip and inverter cover removed.

  1. Enter the following menus: Powertrain / Engine Control / Data List.

  1. Read the "Inverter Temp-(MG1)" value.

    OK:
    401°F (205°C)

  1. Turn the power switch OFF.

  1. Reconnect the inverter connector.

  1. Reinstall the inverter cover .

  1. Reinstall the service plug grip .



OK
REPLACE INVERTER WITH CONVERTER ASSEMBLY
NG


3.READ VALUE OF THE TECHSTREAM (CHECK FOR +B SHORT IN HYBRID VEHICLE CONTROL ECU)


    A065744E41
  1. Disconnect the H15 HV control ECU connector.



    A126232E04
  1. Turn the power switch ON (IG).

    HINT:
    DTCs for the interlock switch system are output when turning the power switch ON (IG) with both service plug grip and inverter cover removed.

  1. Enter the following menus: Powertrain / Engine Control / Data List.

  1. Read the "Inverter Temp-(MG1)" value.

    OK:
    401°F (205°C)

  1. Reconnect the HV control ECU connector.



NG
REPLACE HYBRID VEHICLE CONTROL ECU
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

4.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - INVERTER)

CAUTION:
Wear insulated gloves before performing the following operation.

  1. Turn the power switch OFF.

  1. Remove the service plug grip .

    NOTICE:
    Turning the power switch ON (READY) with the service plug grip removed could cause malfunction. Therefore, never turn the power switch ON (READY) in this state.

  1. Remove the inverter cover .



    A065744E41
  1. Disconnect the H15 HV control ECU connector.



    A092041E33
  1. Disconnect the I10 inverter connector.

  1. Measure the resistance between the wire harness side connectors.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    GIVT (H15-27) - GIVT (I10-21)
    Below 1 Ω
    GINV (H15-23) - GINV (I10-16)
    Below 1 Ω
    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    GIVT (H15-27) or GIVT (I10-21) - Body ground
    10 kΩ or higher
    GINV (H15-23) or GINV (I10-16) - Body ground
    10 kΩ or higher

  1. Reconnect the inverter connector.

  1. Reconnect the HV control ECU connector.

  1. Reinstall the inverter cover .

  1. Reinstall the service plug grip .



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK HYBRID VEHICLE CONTROL ECU (GIVT VOLTAGE)


    A093719E05
  1. Turn the power switch ON (IG).

    HINT:
    DTCs for the interlock switch system are output when turning the power switch ON (IG) with both service plug grip and inverter cover removed.

  1. Measure the voltage between the terminals of the H15 HV control ECU connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    GIVT (H15-27) - GINV (H15-23)
    2.0 to 4.5 V



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY
OK

REPLACE HYBRID VEHICLE CONTROL ECU