DTC P0AEF-275 Drive Motor Inverter Temperature Sensor "A" Circuit Low |
DTC P0AF0-274 Drive Motor Inverter Temperature Sensor "A" Circuit High |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0AEF | 275 | Open or GND short in motor inverter temperature sensor circuit |
|
| P0AF0 | 274 | +B short in motor inverter temperature sensor circuit |
|
| Temperature Displayed | Malfunction |
| -58°F (-50°C) | +B short circuit |
| 401°F (205°C) | Open or GND short circuit |

| 1.READ VALUE OF THE TECHSTREAM (INVERTER TEMP-(MG2)) |
Connect the Techstream to the DLC3.
Turn the power switch ON (IG).
Enter the following menus: Powertrain / Engine Control / Data List.
Read the "Inverter Temp-(MG2") value.
| Temperature Displayed | Proceed to |
| -58°F (-50°C) | A |
| 401°F (205°C) | B |
| -57°F to 400°F (-49°C to 204°C) | C |
|
| ||||
|
| ||||
| A | |
| 2.READ VALUE OF THE TECHSTREAM (CHECK FOR +B SHORT IN WIRE HARNESS) |
Turn the power switch OFF.
Remove the service plug grip .
Remove the inverter cover .
![]() |
Disconnect the I10 inverter connector.
![]() |
Turn the power switch ON (IG).
Enter the following menus: Powertrain / Engine Control / Data List.
Read the "Inverter Temp-(MG2)" value.
Turn the power switch OFF.
Reconnect the inverter connector.
Reinstall the inverter cover .
Reinstall the service plug grip .
|
| ||||
| NG | |
| 3.READ VALUE OF THE TECHSTREAM (CHECK FOR +B SHORT IN HYBRID VEHICLE CONTROL ECU) |
![]() |
Disconnect the H15 HV control ECU connector.
![]() |
Turn the power switch ON (IG).
Enter the following menus: Powertrain / Engine Control / Data List.
Read the "Inverter Temp-(MG2)" value.
Reconnect the HV control ECU connector.
|
| ||||
| OK | ||
| ||
| 4.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - INVERTER) |
Turn the power switch OFF.
Remove the service plug grip .
Remove the inverter cover .
![]() |
Disconnect the H15 HV control ECU connector.
![]() |
Disconnect the I10 inverter connector.
Measure the resistance between the wire harness side connectors.
| Tester Connection | Specified Condition |
| MIVT (H15-19) - MIVT (I10-26) | Below 1 Ω |
| GINV (H15-23) - GINV (I10-16) | Below 1 Ω |
| Tester Connection | Specified Condition |
| MIVT (H15-19) or MIVT (I10-26) - Body ground | 10 kΩ or higher |
| GINV (H15-23) or GINV (I10-16) - Body ground | 10 kΩ or higher |
Reconnect the inverter connector.
Reconnect the HV control ECU connector.
Reinstall the inverter cover .
Reinstall the service plug grip .
|
| ||||
| OK | |
| 5.INSPECT HYBRID VEHICLE CONTROL ECU (MIVT VOLTAGE) |
![]() |
Turn the power switch ON (IG).
Measure the voltage between the terminals of the H15 HV control ECU connector.
| Tester Connection | Specified Condition |
| MIVT (H15-19) - GINV (H15-23) | 2.0 to 4.5 V |
|
| ||||
| OK | ||
| ||