Home › HYBRID SYSTEM › P112 HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A7A-342    Generator Inverter Performance

DTC    P0A7A-343    Generator Inverter Performance

DTC    P0A7A-519    Generator Inverter Performance

for Preparation Click here


DESCRIPTION

See the description of the inverter .
Upon receiving a generator gate shutdown signal from the HV control ECU, the inverter forcefully stops the operation of the MG1 by turning OFF the power transistors that are actuating the MG1.
The HV control ECU monitors the generator gate shutdown signal line and detects a malfunction.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A7A
342
Open or +B short in generator gate shutdown (GSDN) signal circuit
  1. Wire harness or connector
  2. Inverter with converter assembly
P0A7A
343
GND short in generator gate shutdown (GSDN) signal circuit
  1. Wire harness or connector
  2. Inverter with converter assembly
P0A7A
519
Open in generator gate shutdown (GSDN) signal circuit
  1. Wire harness or connector
  2. Inverter with converter assembly

MONITOR DESCRIPTION

The HV control ECU monitors the generator gate shutdown (GSDN) signal line. If the HV control ECU detects an open or short malfunction of the GSDN signal circuit, the HV control ECU illuminates the MIL and sets a DTC.

MONITOR STRATEGY


Related DTCs
P0A7A (INF 342 / 343 / 519):
Generator inverter / Generator gate shutdown signal malfunction
Required sensor / components
Generator inverter
Frequency of operation
Continuous
Duration
TOYOTA's intellectual property
MIL operation
1 driving cycle
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TOYOTA's intellectual property
Other conditions belong to TOYOTA's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


Generator gate shutdown signal circuit
Open or short

COMPONENT OPERATING RANGE


Generator inverter
DTC P0A7A (INF 342 / 343 / 519) is not detected

WIRING DIAGRAM


A092105E05


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are servicing the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.

HINT:
At least 5 minutes are required to discharge the high-voltage condenser inside the inverter.

1.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - INVERTER)

CAUTION:
Wear insulated gloves before performing the following operation.

  1. Turn the power switch OFF.

  1. Remove the service plug grip .

    NOTICE:
    Turning the power switch ON (READY) with the service plug grip removed could cause malfunction. Therefore, never turn the power switch ON (READY) in this state.



    A065744E34
  1. Disconnect the H15 HV control ECU connector.

  1. Remove the inverter cover .



    A092041E22
  1. Disconnect the I10 inverter connector.

  1. Turn the power switch ON (IG).

    HINT:
    DTCs for the interlock switch system are output when turning the power switch ON (IG) with both service plug grip and inverter cover removed.

  1. Measure the voltage between the terminal of the HV control ECU connector and body ground.

    Standard voltage:
    Tester Connection
    Specified Condition
    GSDN (H15-16) - Body ground
    Below 1 V

  1. Turn the power switch OFF.

  1. Measure the resistance between the wire harness side connectors.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    GSDN (H15-16) - GSDN (I10-20)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    GSDN (H15-16) or GSDN (I10-20) - Body ground
    10 kΩ or higher

  1. Reconnect the inverter connector.

  1. Reconnect the HV control ECU connector.

  1. Reinstall the inverter cover .

  1. Reinstall the service plug grip .



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY