METER / GAUGE SYSTEM > Odo / Trip Switch Malfunction |

| 1.INSPECT ODO / TRIP SWITCH |
![]() |
Remove the ODO / TRIP switch.
Measure the resistance of the switch.
| Tester Connection | Switch Condition | Specified Condition |
| 5 (ODO) - 6 (E) | Push ODO / TRIP switch | Below 1 Ω |
| Release ODO / TRIP switch | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (SWITCH - METER) |
![]() |
Disconnect the H11 switch connector.
Disconnect the C10 meter connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| H11-5 (ODO) - C10-3 | Below 1 Ω |
| H11-6 (E) - C10-2 |
|
| ||||
| OK | ||
| ||