Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Odo / Trip Switch Malfunction

for Preparation Click here


WIRING DIAGRAM


I102419E01


INSPECTION PROCEDURE

1.INSPECT ODO / TRIP SWITCH
E113999E03
  1. Remove the ODO / TRIP switch.

  1. Measure the resistance of the switch.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    5 (ODO) - 6 (E)
    Push ODO / TRIP switch
    Below 1 Ω
    Release ODO / TRIP switch
    10 kΩ or higher



NG
REPLACE ODO / TRIP SWITCH
OK


2.CHECK WIRE HARNESS (SWITCH - METER)
I040071E07
  1. Disconnect the H11 switch connector.

  1. Disconnect the C10 meter connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    H11-5 (ODO) - C10-3
    Below 1 Ω
    H11-6 (E) - C10-2



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE COMBINATION METER