POWER DOOR LOCK CONTROL SYSTEM > All Doors LOCK / UNLOCK Functions do not Operate Via Door Control Switch |

| 1.INSPECT DOOR CONTROL SWITCH |
![]() |
Measure the resistance of the switch.
| Tester Connection | Switch Condition | Specified Condition |
| 3 - 6 | Lock | Below 1 Ω |
| 3 - 5 | Unlock | |
| 3 - 6 | OFF | 10 kΩ or higher |
| 3 - 5 |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (SWITCH - DRIVER SIDE JUNCTION BLOCK AND BODY GROUND) |
![]() |
Disconnect the D11 switch connector.
Disconnect the 1H junction block connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| D11-5 - 1H-14 (UL1) | Below 1 Ω |
| D11-6 - 1H-13 (L1) |
|
| ||||
| OK | ||
| ||