POWER DOOR LOCK CONTROL SYSTEM > Only Rear Door RH LOCK / UNLOCK Functions do not Operate |

| 1.PERFORM ACTIVE TEST BY TECHSTREAM (DOOR LOCK MOTOR) |
Select the Active Test, use the Techstream to generate a control command, and then check that the power door lock operates.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Door Lock | Operate door lock motor for all doors | LOCK / UNLOCK | All doors are closed |
|
| ||||
| OK | |
| 2.INSPECT REAR DOOR LOCK RH (POSITION SWITCH) |
![]() |
Measure the resistance of the position switch.
| Tester Connection | Switch Condition | Specified Condition |
| 6 - 9 | Lock | Below 1 Ω |
| Unlock | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.INSPECT REAR DOOR LOCK RH |
![]() |
Apply battery voltage to the door lock and check operation of the door lock motor.
| Tester Connection | Specified Condition |
| Battery positive (+) → Terminal 4 Battery negative (-) → Terminal 1 | Lock |
| Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 4 | Unlock |
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (MOTOR - DRIVE SIDE JUNCTION BLOCK, ECU AND BODY GROUND) |

Disconnect the D15 lock connector.
Disconnect the B5 ECU connector.
Disconnect the 1H junction block connector.
Measure the resistance of the wire harness side connectors
| Tester Connection | Specified Condition |
| D15-4 - 1H-17 (ACT+) | Below 1 Ω |
| D15-1 - 1H-9 (ACT-) | |
| D15-6 - B5-10 (LSWR) | |
| D15-9 - Body ground |
|
| ||||
| OK | ||
| ||