Home › HYBRID SYSTEM › P112 HYBRID VEHICLE CONTROL › IGCT RELAY

IGCT RELAY > ON-VEHICLE INSPECTION

for Preparation Click here



1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.



2. INSPECT INTEGRATION RELAY (IGCT RELAY)


NOTICE:
IGCT relay is built into the integration relay.



A077561E03

  1. Check the resistance of the HEV fuse.
    If the result is not as specified, replace the fuse.

  1. Measure the resistance of the IGCT relay.

    Standard resistance:
    Tester Connection
    Specified Condition
    7J-1 - 7J-4
    10 kΩ or higher
    7J-1 - 7K-4
    Below 1 Ω
    7J-2 - 7J-3
    Below 1 Ω
    7J-4 - 7K-1
    10 kΩ or higher
    7J-1 - 7J-4
    Below 1 Ω (when battery voltage is applied to terminals 7J-2 and 7J-3)
    7J-1 - 7K-1
    Below 1 Ω (when battery voltage is applied to terminals 7J-2 and 7J-3)

    If the standards are not met, replace the integration relay.