Home › ENGINE › 1NZ-FXE ENGINE CONTROL SYSTEM › CIRCUIT OPENING RELAY

CIRCUIT OPENING RELAY > ON-VEHICLE INSPECTION

for Preparation Click here



1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.



2. INSPECT INTEGRATION RELAY (UNIT C: C/OPN RELAY)

NOTICE:
  1. The EFI relay is built into the integration relay (unit C: C/OPN RELAY).
  2. Some relays are built into the integration relay. The integration relay cannot be disassembled. If there is a malfunction in the circuit of the integration relay, replace the integration relay.



    A135397
  1. Using a screwdriver, detach the 2 claws and disconnect the integration relay from the No. 1 engine room junction block.

    HINT:
    Tape the screwdriver tip before use.

  1. Disconnect the 2 connectors from the integration relay.



    A114366E02
  1. Measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Specified Condition
    3G-5 - 3G-8
    10 kΩ or higher
    3G-5 - 3G-8
    Below 1 Ω
    (when battery voltage is applied to terminals 3G-6 and 3G-7)

    If the result is not as specified, replace the integration relay.

  1. Connect the 2 connectors to the integration relay.

  1. Install the integration relay to the engine room No. 1 junction block.



3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


4. PERFORM INITIALIZATION
  1. Perform initialization (Click here).

    NOTICE:
    Certain system need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.