Home › ENGINE › 1NZ-FXE FUEL › FUEL TANK

FUEL TANK > INSPECTION

for Preparation Click here



1. INSPECT FUEL TANK ASSEMBLY WITH FUEL PUMP


    A087570E02
  1. Measure the resistance between terminals 3 and 7.

    Standard resistance:
    0.2 to 3.0 Ω at 20°C (68°F)

    If the resistance is not as specified, replace the fuel tank assembly.



    A087571E02
  1. Check that the motor operates when battery voltage is applied across the terminals.

    NOTICE:
    1. Perform the check quickly (shorter than 10 seconds).
    2. Keep the battery as far away the fuel tank as possible.
    3. Always turn the voltage on and off on the battery side, not the fuel tank side.

    If the motor does not operate, replace the fuel tank assembly.