ELECTRIC INVERTER COMPRESSOR > INSTALLATION |
| 1. INSPECT COMPRESSOR OIL |
![]() |
Gradually discharge inert gas (helium) from the service valve when replacing the electric inverter compressor with a new one. Drain the following amount of oil from the new electric inverter compressor before installation.
| 2. INSTALL ELECTRIC INVERTER COMPRESSOR ASSEMBLY |
![]() |
Temporarily install the compressor with the 2 bolts.
![]() |
Fully install the compressor with the 2 bolts.
![]() |
Install the remaining bolt.
![]() |
Connect the wire harness.
Connect the 3 wire harness clamps.
Connect the connector. (1)
Lock the green-colored lock. (2)
| 3. INSTALL SUCTION HOSE SUB-ASSEMBLY |
![]() |
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the electric inverter compressor assembly.
Install the O-ring to the suction hose.
Install the suction hose with the bolt.
| 4. INSTALL DISCHARGE HOSE SUB-ASSEMBLY |
![]() |
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the electric inverter compressor.
Install the O-ring to the discharge hose.
Install the discharge hose with the bolt.
| 5. INSTALL SERVICE PLUG GRIP |
| 6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 7. PERFORM INITIALIZATION |
Perform initialization (Click here).
| 8. INSTALL REAR NO. 3 FLOOR BOARD |
| 9. INSTALL DECK FLOOR BOX REAR |
| 10. INSTALL REAR NO.2 FLOOR BOARD |
| 11. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 12. WARM UP COMPRESSOR |
Turn the A/C switch on for at least 1 minute to warm up the compressor.
| 13. INSPECT FOR REFRIGERANT LEAK |
After recharging the refrigerant gas, inspect for refrigerant leak gas using a halogen leak detector.
After recharging the refrigerant gas, prepare the vehicle for a refrigerant gas leakage check by making sure the following conditions are met.
The ignition switch is OFF.
The vehicle is in a place with good air ventilation and without any volatile gases, such as evaporated gasoline or exhaust gas. The detector is very sensitive to volatile gases. If volatile gases are unavoidable, the vehicle must be lifted up.
Some refrigerant remains in the refrigerant system.
The compressor is OFF and its pressure is approximately 392 to 588 kPa (4 to 6 kgf/cm2).
![]() |
Bring the gas leak detector close to the drain hose with the detector's power off.
If a gas leak is not detected on the drain hose, remove the blower motor control from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.
Disconnect the pressure switch connector and wait for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.