Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › ELECTRIC INVERTER COMPRESSOR

ELECTRIC INVERTER COMPRESSOR > INSTALLATION

for Preparation Click here



1. INSPECT COMPRESSOR OIL


    I039541E01
  1. Gradually discharge inert gas (helium) from the service valve when replacing the electric inverter compressor with a new one. Drain the following amount of oil from the new electric inverter compressor before installation.

    Standard amount:
    (Oil capacity inside new electric inverter compressor 100 + 15 cc (3.52 + 0.53 fl.oz.)) - (Remaining oil amount in the removed compressor assembly with the motor (with motor compressor assembly)) = (Oil amount to be removed before installation)

    NOTICE:
    1. Observe the precautions on the cooler removal/installation procedures when checking the amount of compressor oil.
    2. Because compressor oil remains in the pipes of the vehicle, if a new compressor is installed without removing the oil inside, the amount of oil becomes too great, preventing heat exchange in the refrigerant cycles and causing refrigerant failure and/or abnormal vibration.
    3. Check for oil leakage if the remaining oil amount in the removed compressor is too low.
    4. If any compressor oil other than ND-OIL 11 is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.



2. INSTALL ELECTRIC INVERTER COMPRESSOR ASSEMBLY


    E072576E02
  1. Temporarily install the compressor with the 2 bolts.

    NOTICE:
    Install the bolts in the order indicated in the illustration.



    I041159E02
  1. Fully install the compressor with the 2 bolts.

    Torque:
    25 N*m{ 255 kgf*cm , 18 ft.*lbf }

    NOTICE:
    Tighten them in the order indicated in the illustration.



    I041160E01
  1. Install the remaining bolt.

    Torque:
    25 N*m{ 255 kgf*cm , 18 ft.*lbf }



    I041121E03
  1. Connect the wire harness.

    NOTICE:
    Wear insulated gloves when performing the procedures.


    1. Connect the 3 wire harness clamps.

    2. Connect the connector. (1)

    3. Lock the green-colored lock. (2)



3. INSTALL SUCTION HOSE SUB-ASSEMBLY


    I038561E01
  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the electric inverter compressor assembly.

    Compressor oil:
    ND-OIL 11 or equivalent

    NOTICE:
    1. Do not use any compressor oil other than ND-OIL 11.
    2. If any compressor oil other than ND-OIL 11 is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.

  1. Install the O-ring to the suction hose.

  1. Install the suction hose with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



4. INSTALL DISCHARGE HOSE SUB-ASSEMBLY


    I038560E01
  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the electric inverter compressor.

    Compressor oil:
    ND-OIL 11 or equivalent

    NOTICE:
    1. Do not use any compressor oil other than ND-OIL 11.
    2. If any compressor oil other than ND-OIL 11 is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.

  1. Install the O-ring to the discharge hose.

  1. Install the discharge hose with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



5. INSTALL SERVICE PLUG GRIP


6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


7. PERFORM INITIALIZATION
  1. Perform initialization (Click here).

    NOTICE:
    Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.



8. INSTALL REAR NO. 3 FLOOR BOARD


9. INSTALL DECK FLOOR BOX REAR


10. INSTALL REAR NO.2 FLOOR BOARD


11. CHARGE REFRIGERANT
  1. Perform vacuum purging using a vacuum pump.



  1. Charge refrigerant HFC-134a (R134a).

    Amount:
    450 +-30 g (15.9 +-1.1 oz.)

    SST
    09985-20010   (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02090, 09985-02110, 09985-02130, 09985-02140, 09985-02150)


    I030082E09

    NOTICE:
    1. Do not turn the A/C on before charging refrigerant as the cooler compressor does not work properly without any refrigerant. Operating without any refrigerant causes it to overheat.
    2. Approximately 100 g (3.53 oz.) of refrigerant may need to be charged after bubbles disappear. The refrigerant amount should be checked by quantity, and not with the sight glass.

    HINT:
    Prepare a service can to recharge the refrigerant if using the refrigerant gas collected with the Freon collection/recycling device because the collective rate of the device is approximately 90%.



12. WARM UP COMPRESSOR
  1. Turn the A/C switch on for at least 1 minute to warm up the compressor.

    NOTICE:
    Be sure to warm up the compressor when turning the A/C on after removing and installing the cooler refrigerant lines (including the compressor) to prevent damage to the compressor.



13. INSPECT FOR REFRIGERANT LEAK
  1. After recharging the refrigerant gas, inspect for refrigerant leak gas using a halogen leak detector.

  1. After recharging the refrigerant gas, prepare the vehicle for a refrigerant gas leakage check by making sure the following conditions are met.

    1. The ignition switch is OFF.

    2. The vehicle is in a place with good air ventilation and without any volatile gases, such as evaporated gasoline or exhaust gas. The detector is very sensitive to volatile gases. If volatile gases are unavoidable, the vehicle must be lifted up.

    3. Some refrigerant remains in the refrigerant system.

    4. The compressor is OFF and its pressure is approximately 392 to 588 kPa (4 to 6 kgf/cm2).



    N014519E04
  1. Bring the gas leak detector close to the drain hose with the detector's power off.

    HINT:
    1. After the blower motor has stopped, leave the cooling unit as it is for more than 15 minutes.
    2. Expose the gas leak detector sensor under the drain hose.
    3. When bringing the gas leak detector close to the drain hose, make sure that the gas leak detector does not react to the volatile gases.

  1. If a gas leak is not detected on the drain hose, remove the blower motor control from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.

  1. Disconnect the pressure switch connector and wait for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.