ELECTRIC INVERTER COMPRESSOR > REMOVAL |
| 1. REMOVE REAR NO. 2 FLOOR BOARD |
| 2. REMOVE DECK FLOOR BOX REAR |
| 3. REMOVE REAR NO.3 FLOOR BOARD |
| 4. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 5. REMOVE SERVICE PLUG GRIP |
| 6. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM |
Turn the A/C switch on.
Operate the A/C with the setting temperature at 25 °C (77°F) and the blower level at LO for 10 minutes to circulate the refrigerant, and collect compressor oil remaining in each component into the cooler compressor as much as possible.
Stop the engine.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
| 7. DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY |
![]() |
Remove the bolt and disconnect the discharge hose.
Remove the O-ring from the discharge hose.
| 8. DISCONNECT SUCTION HOSE SUB-ASSEMBLY |
![]() |
Remove the bolt and disconnect the suction hose.
Remove the O-ring from the suction hose.
| 9. REMOVE ELECTRIC INVERTER COMPRESSOR ASSEMBLY |
![]() |
Release the green-colored lock. (1)
Disconnect the connector. (2)
Detach the 3 clamps and disconnect the wire harness.
![]() |
Remove the 3 bolts and electric inverter compressor.