Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › ELECTRIC INVERTER COMPRESSOR

ELECTRIC INVERTER COMPRESSOR > REMOVAL

for Preparation Click here



1. REMOVE REAR NO. 2 FLOOR BOARD


2. REMOVE DECK FLOOR BOX REAR


3. REMOVE REAR NO.3 FLOOR BOARD


4. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL


5. REMOVE SERVICE PLUG GRIP


6. DISCHARGE REFRIGERANT FROM REFRIGERATION SYSTEM
  1. Turn the A/C switch on.

  1. Operate the A/C with the setting temperature at 25 °C (77°F) and the blower level at LO for 10 minutes to circulate the refrigerant, and collect compressor oil remaining in each component into the cooler compressor as much as possible.

  1. Stop the engine.

  1. Recover the refrigerant from the A/C system using a refrigerant recovery unit.



7. DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY


    I038560E02
  1. Remove the bolt and disconnect the discharge hose.

  1. Remove the O-ring from the discharge hose.

    NOTICE:
    Seal the openings of the disconnected parts of the discharge hose and electric inverter compressor assembly using vinyl tape to prevent moisture and foreign matter from entering them.



8. DISCONNECT SUCTION HOSE SUB-ASSEMBLY


    I038561E01
  1. Remove the bolt and disconnect the suction hose.

  1. Remove the O-ring from the suction hose.

    NOTICE:
    Seal the openings of the disconnected parts of the suction hose and electric inverter compressor assembly using vinyl tape to prevent moisture and foreign matter from entering them.



9. REMOVE ELECTRIC INVERTER COMPRESSOR ASSEMBLY


    I038562E03
  1. Release the green-colored lock. (1)

  1. Disconnect the connector. (2)

  1. Detach the 3 clamps and disconnect the wire harness.

    NOTICE:
    1. Wear insulated gloves when performing the procedures.
    2. Insulate the connector by sealing it with tape.



    I038563E01
  1. Remove the 3 bolts and electric inverter compressor.