Item
| Condition to Transfer
| Condition to Return
| Warning Indication
|
Over voltage*1
| Detects input voltage of more than 18.5 V
| Detects less than 17.5 V
| Appears
|
Low voltage*1
| Detects input voltage of less than 9 V
| Detects more than 9.3 V
| Does not appear
|
Vehicle height sensor malfunction*1
| When either condition below is met:
- Detects vehicle height sensor supply voltage of less than 4 V
- Detects vehicle height signal malfunction (not within 0.5 V and 4.5 V)
- Vehicle height sensor power source supply line is open, or short to GND
- Vehicle height sensor GND line is open
| Detects normal voltage for 5 sec.
| Appears
|
Microcomputer*1
| Detects ECU malfunction
| Cancels reset of microcomputer
| Appears
|
Leveling angle calculation value*2
| Calculates values out of the actuator's operative range
| -
| Does not appear
|