Home › HYBRID SYSTEM › P112 HYBRID BATTERY CONTROL › HYBRID BATTERY SYSTEM

DTC    P0A81    Hybrid Battery Pack Cooling Fan 1

for Preparation Click here


DESCRIPTION

Refer to DTC P0A84 .

DTC No.
DTC Detection Condition
Trouble Area
P0A81
Voltage at motor is out of predetermined range in proportion to target control voltage (1 trip detection logic)
  1. Quarter vent duct (blower motor controller)
  2. Battery ECU

WIRING DIAGRAM

Refer to DTC P0A84 .

INSPECTION PROCEDURE

1.READ DTC OUTPUT (DTC P0A1F IS OUTPUT)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch ON (IG) and the tester ON.

  1. Enter the following menus: Powertrain / HV Battery / DTC.

  1. Read DTCs.

    Result:
    Display (DTC Output)
    Proceed to
    P0A81
    A
    P0A81 and P0A1F
    B
    P0A81 and P0A84
    C



B
REPLACE BATTERY ECU

C
GO TO DTC P0A84 CHART
A


2.REPLACE QUARTER VENT DUCT (BATTERY BLOWER MOTOR CONTROLLER)
  1. Replace the quarter vent duct (blower motor controller).

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch ON (IG) and the tester ON.

  1. Enter the following menus: Powertrain / HV Battery / DTC.

  1. Clear the DTCs and freeze frame data.

  1. Perform a simulation test.


NEXT


3.READ DTC OUTPUT (DTC P0A81 IS OUTPUT AGAIN)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch ON (IG) and the tester ON.

  1. Enter the following menus: Powertrain / HV Battery / DTC.

  1. Read DTCs.

    Result:
    DTC P0A81 is output again



YES
REPLACE BATTERY ECU
NO

SYSTEM IS OK