ELECTRONIC SHIFT LEVER SYSTEM > TERMINALS OF ECU |
| CHECK TRANSMISSION CONTROL ECU |

| Terminal No. (Symbols) | Wiring Color | Terminal Description | Condition | Specified Condition |
| T4-1 (+B) - T4-15 (E1) | L - W-B | Power source | Power switch ON (IG) | 9 to 14 V |
| T4-2 (E02) - Body ground | W-B - Body ground | Ground | Always | Below 1 V |
| T4-3 (E01) - Body ground | W-B - Body ground | Ground | Always | Below 1 V |
| T4-4 (RZ1) - T4-16 (E2) | L - P | Rotation angle sensor signal | Power switch ON (IG) | 4 to 5.5 V |
| T4-5 (RB) - T4-16 (E2) | GR - P | Rotation angle sensor signal | Power switch ON (IG) | 4 to 5.5 V |
| T4-6 (RA) - T4-16 (E2) | LG - P | Rotation angle sensor signal | Power switch ON (IG) | 4 to 5.5 V |
| T4-7 (PCON) - T4-15 (E1) | LG - W-B | Communication bus | Power switch ON (IG) | Pulse generation (see wave form 1) |
| T4-8 (PPOS) - T4-15 (E1) | W - W-B | Communication bus | Power switch ON (IG) | Pulse generation (see wave form 2) |
| T4-9 (IND) - T4-15 (E1) | R - W-B | P position switch indicator light | P position switch ON | Below 1 V |
| T4-10 (MWA) - T4-15 (E1) | W - W-B | Parking lock motor | Power switch ON (IG) | 9 to 14 V |
| T4-11 (MVA) - T4-15 (E1) | R - W-B | Parking lock motor | Power switch ON (IG) | 9 to 14 V |
| T4-12 (MUA) - T4-15 (E1) | B - W-B | Parking lock motor | Power switch ON (IG) | 9 to 14 V |
| T4-13 (BATT) - T4-15 (E1) | L - W-B | Power source (RAM) | Always | 9 to 14 V |
| T4-14 (BMA) - T4-15 (E1) | B - W-B | P CON relay | Power switch ON (IG) | 9 to 14 V |
| T4-15 (E1) - Body ground | W-B - Body ground | Ground | Always | Below 1 V |
| T4-16 (E2) - Body ground | P - Body ground | Ground | Always | Below 1 V |
| T4-17 (VC) - T4-16 (E2) | O - P | Power source (Rotation angle sensor) | Power switch ON (IG) | 4 to 5.5 V |
| T4-18 (MPX2) - T4-15 (E1) | B - W-B | Multiplex communication | Power switch OFF Power switch ON (IG) | Below 1 V Pulse generation |
| T4-19 (MPX1) - T4-15 (E1) | GR - W-B | Multiplex communication | Power switch OFF Power switch ON (IG) | Below 1 V Pulse generation |
| T4-20 (SIL) - T4-15 (E1) | W - W-B | Diagnosis tester communication | Power switch ON (IG) | 8 V or higher |
![]() |
Using an oscilloscope, check the waveform 1.
| Item | Content |
| Symbols | PCON - E1 |
| Tool setting | 5 V/DIV., 20 msec./DIV. |
| Condition | Power switch ON (IG) |
![]() |
Using an oscilloscope, check the waveform 2.
| Item | Content |
| Symbols | PPOS - E1 |
| Tool setting | 5 V/DIV., 20 msec./DIV. |
| Condition | Power switch ON (IG) |