Home › HYBRID SYSTEM › HYBRID TRANSMISSION / TRANSAXLE › ELECTRONIC SHIFT LEVER SYSTEM

ELECTRONIC SHIFT LEVER SYSTEM > TERMINALS OF ECU

for Preparation Click here



CHECK TRANSMISSION CONTROL ECU

HINT:
Inspect the connectors from the back side while the connector is connected.


B119765E02


Terminal No. (Symbols)
Wiring Color
Terminal Description
Condition
Specified Condition
T4-1 (+B) - T4-15 (E1)
L - W-B
Power source
Power switch ON (IG)
9 to 14 V
T4-2 (E02) - Body ground
W-B - Body ground
Ground
Always
Below 1 V
T4-3 (E01) - Body ground
W-B - Body ground
Ground
Always
Below 1 V
T4-4 (RZ1) - T4-16 (E2)
L - P
Rotation angle sensor signal
Power switch ON (IG)
4 to 5.5 V
T4-5 (RB) - T4-16 (E2)
GR - P
Rotation angle sensor signal
Power switch ON (IG)
4 to 5.5 V
T4-6 (RA) - T4-16 (E2)
LG - P
Rotation angle sensor signal
Power switch ON (IG)
4 to 5.5 V
T4-7 (PCON) - T4-15 (E1)
LG - W-B
Communication bus
Power switch ON (IG)
Pulse generation
(see wave form 1)
T4-8 (PPOS) - T4-15 (E1)
W - W-B
Communication bus
Power switch ON (IG)
Pulse generation
(see wave form 2)
T4-9 (IND) - T4-15 (E1)
R - W-B
P position switch indicator light
P position switch ON
Below 1 V
T4-10 (MWA) - T4-15 (E1)
W - W-B
Parking lock motor
Power switch ON (IG)
9 to 14 V
T4-11 (MVA) - T4-15 (E1)
R - W-B
Parking lock motor
Power switch ON (IG)
9 to 14 V
T4-12 (MUA) - T4-15 (E1)
B - W-B
Parking lock motor
Power switch ON (IG)
9 to 14 V
T4-13 (BATT) - T4-15 (E1)
L - W-B
Power source (RAM)
Always
9 to 14 V
T4-14 (BMA) - T4-15 (E1)
B - W-B
P CON relay
Power switch ON (IG)
9 to 14 V
T4-15 (E1) - Body ground
W-B - Body ground
Ground
Always
Below 1 V
T4-16 (E2) - Body ground
P - Body ground
Ground
Always
Below 1 V
T4-17 (VC) - T4-16 (E2)
O - P
Power source (Rotation angle sensor)
Power switch ON (IG)
4 to 5.5 V
T4-18 (MPX2) - T4-15 (E1)
B - W-B
Multiplex communication
Power switch OFF
Power switch ON (IG)
Below 1 V
Pulse generation
T4-19 (MPX1) - T4-15 (E1)
GR - W-B
Multiplex communication
Power switch OFF
Power switch ON (IG)
Below 1 V
Pulse generation
T4-20 (SIL) - T4-15 (E1)
W - W-B
Diagnosis tester communication
Power switch ON (IG)
8 V or higher


    C126766E01
  1. Using an oscilloscope, check the waveform 1.
    Waveform 1 (Reference) 
    Item
    Content
    Symbols
    PCON - E1
    Tool setting
    5 V/DIV., 20 msec./DIV.
    Condition
    Power switch ON (IG)



  2. C126767E01
  3. Using an oscilloscope, check the waveform 2.
    Waveform 2 (Reference) 
    Item
    Content
    Symbols
    PPOS - E1
    Tool setting
    5 V/DIV., 20 msec./DIV.
    Condition
    Power switch ON (IG)