Home › HYBRID SYSTEM › HYBRID TRANSMISSION / TRANSAXLE › ELECTRONIC SHIFT LEVER SYSTEM

DTC    C2303    Relay Malfunction (+B Short)

for Preparation Click here


DESCRIPTION

The transaxle parking lock control relay (Marking: P CON) is activated by output voltage from the transmission control ECU and supplies power to the shift control actuator. The transmission control ECU outputs this DTC when it detects a malfunction in the transaxle parking lock control relay.

DTC No.
DTC Detection Condition
Trouble Area
C2303
When both conditions below are met:
  1. The transaxle parking lock control relay is off.
  2. Voltage of the transmission control ECU terminals MUA, MVA, and MWA is 6 V or more for 64 msec. or more.
  1. Transaxle parking lock control relay (P CON relay)
  2. Transmission control ECU
  3. Wire harness or connector

WIRING DIAGRAM


C126769E02


INSPECTION PROCEDURE

1.INSPECT TRANSAXLE PARKING LOCK CONTROL RELAY (Marking: P CON)


    B112776E02
  1. Remove the P CON MTR relay from the engine room relay block.

  1. Measure the resistance of the relay.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 5
    Below 1 Ω
    (When battery voltage is applied to terminals 1 and 2)



NG
REPLACE TRANSAXLE PARKING LOCK CONTROL RELAY
OK


2.CHECK WIRE HARNESS (TRANSMISSION CONTROL ECU - CONTROL RELAY)


    B118155E12
  1. Disconnect the T4 ECU connector.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    T4-14 (BMA) - Body ground
    Below 1 V



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK


3.CHECK WIRE HARNESS (TRANSMISSION CONTROL ECU - ACTUATOR)


    B118155E18
  1. Disconnect the T4 ECU connector.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    T4-10 (MWA) - Body ground
    Below 1 V
    T4-11 (MVA) - Body ground
    Below 1 V
    T4-12 (MUA) - Body ground
    Below 1 V



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK


4.CHECK WIRE HARNESS (SHIFT CONTROL ACTUATOR - CONTROL RELAY)


    C126783E01
  1. Disconnect the S1 actuator connector.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    S1-2 (MGNA) - Body ground
    Below 1 V



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE TRANSMISSION CONTROL ECU