SMART KEY SYSTEM > Driver Side Door Entry Lock and Unlock Functions do not Operate |

| 1.CHECK MANUAL DOOR LOCK AND UNLOCK OPERATION |
Check that the manual door lock and unlock function operates normally.
|
| ||||
| OK | |
| 2.PERFORM ACTIVE TEST BY TECHSTREAM (DOOR ELECTRICAL KEY OSCILLATOR LH) |
Select the Active Test, use the Techstream to generate a control command, and then check that the oscillator operates.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| D Transmitter | Driver side transmitter | ON / OFF | - |
|
| ||||
| NG | |
| 3.CHECK WIRE HARNESS (DOOR ELECTRICAL KEY OSCILLATOR LH - CERTIFICATION ECU, BATTERY AND BODY GROUND) |
![]() |
Disconnect the D16 oscillator connector.
Disconnect the S11 ECU connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| D16-4 (CLG) - S11-13 (CLG1) | Below 1 Ω |
| D16-4 (CLG) or S11-13 (CLG1) - Body ground | 10 kΩ or higher |
| D16-8 (GND) - Body ground | Below 1 Ω |
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| D16-1 (+B) - Body ground | 10 to 14 V |
|
| ||||
| OK | |
| 4.CHECK DOOR ELECTRICAL KEY OSCILLATOR LH (CLG VOLTAGE) |
![]() |
Measure the voltage between the terminals of the connector when the power switch is operated.
| Tester Connection | Condition | Specified Condition |
| D16-4 (CLG) - Body ground | Power switch OFF | Alternating between 5 V and below 1 V |
| Power switch ON (IG) | Below 1 V |
|
| ||||
| OK | ||
| ||