Home › BODY ELECTRICAL › METER › COMBINATION METER

COMBINATION METER > REASSEMBLY

for Preparation Click here



1. INSTALL COMBINATION METER CASE


2. INSTALL NO. 4 METER CIRCUIT PLATE


B132966

NOTICE:
When reassembling the combination meter assembly, eliminate static electricity by touching the vehicle body to prevent the components from being damaged.

  1. Push the connector lock in the direction indicated by the arrow in the illustration, and install the meter circuit plate.



3. INSTALL NO. 3 METER CIRCUIT PLATE


B132965

NOTICE:
When reassembling the combination meter assembly, eliminate static electricity by touching the vehicle body to prevent the components from being damaged.

  1. Push the connector lock in the direction indicated by the arrow in the illustration, and install the meter circuit plate.



4. INSTALL NO. 3 COMBINATION METER COVER


B132964
  1. Attach the 2 claws to install the combination meter cover.

  1. Install the 4 screws.



5. INSTALL NO. 1 COMBINATION METER REFLECTOR


B075530E02
  1. Install the combination reflector with the screw.



    B132962
  1. Install the 4 clips.



6. INSTALL NO. 3 COMBINATION METER CASE


7. INSTALL NO. 2 METER CIRCUIT PLATE


B075528E04

NOTICE:
When reassembling the combination meter assembly, eliminate static electricity by touching the vehicle body to prevent the components from being damaged.

  1. Attach the 4 claws to install the meter circuit plate.



    B132961
  1. Push the connector lock in the direction indicated by the arrow in the illustration and install the No. 4 meter circuit plate from the No. 2 meter circuit plate.



8. INSTALL NO. 2 COMBINATION METER COVER


B075526E04

NOTICE:
When reassembling the combination meter assembly, eliminate static electricity by touching the vehicle body to prevent the components from being damaged.

  1. Attach the 2 claws to install the combination meter cover.



    B075525E02
  1. Install the 2 screws.



9. INSTALL NO. 2 COMBINATION METER CASE


10. INSTALL METER CIRCUIT PLATE


B075524E04

NOTICE:
When reassembling the combination meter assembly, eliminate static electricity by touching the vehicle body to prevent the components from being damaged.

  1. Attach the 5 claws to install the meter circuit plate.



    B132963
  1. Push the connector lock in the direction indicated by the arrow in the illustration and install the No. 3 meter circuit plate to the meter circuit plate.



11. INSTALL NO. 1 COMBINATION METER COVER


B075522E04
  1. Attach the 2 claws to install the combination meter cover.



    B075521E02
  1. Install the 2 screws.