SFI SYSTEM > VC Output Circuit |

| 1.CHECK MIL |
Check that the MIL (Malfunction Indicator Lamp) lights up when turning the power switch ON (IG).
|
| ||||
| NG | |
| 2.CHECK CONNECTION BETWEEN TECHSTREAM AND ECM |
Connect Techstream to the DLC3.
Turn the power switch ON (IG) and turn Techstream ON.
Check the connection between Techstream and ECM.
| Condition | Proceed to |
| Communication is possible | A |
| Communication is not possible | B |
|
| ||||
| B | |
| 3.CHECK ECM (VC VOLTAGE) |
![]() |
Turn the power switch ON (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E4-18 (VC) - E5-28 (E1) | Voltage is not 5 V |
| NEXT | |
| 4.CHECK MIL (THROTTLE POSITION SENSOR) |
Disconnect the T3 throttle body connector.
Turn the power switch ON (IG).
Check the MIL.
| Condition | Proceed to |
| MIL illuminates | A |
| MIL does not illuminate | B |
|
| ||||
| B | |
| 5.CHECK MIL (WATER VALVE) |
Disconnect the W5 water valve connector.
Turn the power switch ON (IG).
Check the MIL.
| Condition | Proceed to |
| MIL illuminates | A |
| MIL does not illuminate | B |
|
| ||||
| B | |
| 6.CHECK MIL (CANISTER PUMP MODULE) |
Disconnect the V7 canister pump module connector.
Turn the power switch ON (IG).
Check the MIL.
| Condition | Proceed to |
| MIL illuminates | A |
| MIL does not illuminate | B |
|
| ||||
| B | |
| 7.CHECK MIL (VAPOR PRESSURE SENSOR) |
Disconnect the V6 vapor pressure sensor connector.
Turn the power switch ON (IG).
Check the MIL.
| Condition | Proceed to |
| MIL illuminates | A |
| MIL does not illuminate | B |
|
| ||||
| B | |
| 8.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND) |
![]() |
Disconnect the T3 throttle body connector.
Disconnect the W5 water valve connector.
Disconnect the V7 canister pump module connector.
Disconnect the V6 vapor pressure sensor connector.
Disconnect the E4 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| E4-18 (VC) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||