AIR CONDITIONING SYSTEM > TERMINALS OF ECU |

| CHECK AIR CONDITIONING AMPLIFIER |
Measure the voltage and resistance of the connectors.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| AIR (A8-22) - GND (A8-1) | G - W-B | Recirculation / Fresh switch signal | Power switch ON (IG) Recirculation / Fresh switch: FRESH | Below 1 V |
| AIR (A8-22) - GND (A8-1) | G - W-B | Recirculation / Fresh switch signal | Power switch ON (IG) Recirculation / Fresh switch: RECIRC | 10 to 14 V |
| AIF (A8-23) - GND (A8-1) | P - W-B | Recirculation / Fresh switch signal | Power switch ON (IG) Recirculation / Fresh switch: RECIRC | Below 1 V |
| AIF (A8-23) - GND (A8-1) | P - W-B | Recirculation / Fresh switch signal | Power switch ON (IG) Recirculation / Fresh switch: FRESH | 10 to 14 V |
| AOF (A8-16) - GND (A8-1) | B - W-B | Mode switch signal | Power switch ON (IG) Mode switch: DEF | Below 1 V |
| AOF (A8-16) - GND (A8-1) | B - W-B | Mode switch signal | Power switch ON (IG) Mode switch: FACE | 10 to 14 V |
| AOD (A8-24) - GND (A8-1) | Y - W-B | Mode switch signal | Power switch ON (IG) Mode switch: FACE | Below 1 V |
| AOD (A8-24) - GND (A8-1) | Y - W-B | Mode switch signal | Power switch ON (IG) Mode switch: DEF | 10 to 14 V |
| TPI (A7-19) - SGTPI (A7-4) | V - L | Recirculation / Fresh switch signal | Power switch ON (IG) Recirculation / Fresh switch: RECIRC | 4 V |
| TPI (A7-19) - SGTPI (A7-4) | V - L | Recirculation / Fresh switch signal | Power switch ON (IG) Recirculation / Fresh switch: FRESH | 1 V |
| TPM (A7-18) - SGTPM (A7-23) | LG - P | Mode switch signal | Power switch ON (IG) Mode switch: FACE | 4 V |
| TPM (A7-18) - SGTPM (A7-23) | LG - P | Mode switch signal | Power switch ON (IG) Mode switch: DEF | 1 V |
| TP (A7-20) - SGTP (A7-14) | L - LG | Temperature switch signal | Power switch ON (IG) Temperature switch: Max. COOL | 4 V |
| TP (A7-20) - SGTP (A7-14) | L - LG | Temperature switch signal | Power switch ON (IG) Temperature switch: Max. HOT | 1 V |
| SGTE (A7-5) - Body ground | Y - Body ground | Ground for evaporator temperature sensor | Always | Below 1 Ω |
| TE (A7-7) - SGTE (A7-5) | B - Y | Evaporator temperature sensor signal | Power switch ON (IG) Evaporator temperature: 15°C (59°F) | 2 to 2.4 V |
| TE (A7-7) - SGTE (A7-5) | B - Y | Evaporator temperature sensor signal | Power switch ON (IG) Evaporator temperature: 15°C (59°F) | 1.4 to 1.8 V |
| S5TPI (A7-3) - SGTPI (A7-4) | B - L | Power supply for air inlet damper position sensor | Power switch ON (IG) | 4.5 to 5.5 V |
| AMC (A8-19) - GND (A8-1) | B - W-B | Temperature switch | Power switch ON (IG) Temperature switch: Max. HOT | Below 1 V |
| AMC (A8-19) - GND (A8-1) | B - W-B | Temperature switch | Power switch ON (IG) Temperature switch: Max. COOL | 10 to 14 V |
| AMH (A8-17) - GND (A8-1) | R - W-B | Temperature switch | Power switch ON (IG) Temperature switch: Max. COOL | Below 1 V |
| AMH (A8-17) - GND (A8-1) | R - W-B | Temperature switch | Power switch ON (IG) Temperature switch: Max. HOT | 10 to 14 V |
| SGTPI (A7-4) - Body ground | L - Body ground | Ground for air inlet damper position sensor | Always | Below 1 Ω |
| SGTPM (A7-23) - Body ground | P - Body ground | Ground for air outlet damper position sensor | Always | Below 1 Ω |
| SGTP (A7-14) - Body ground | LG - Body ground | Ground for air mix damper position sensor | Always | Below 1 Ω |
| S5TPM (A7-11) - SGTPM (A7-23) | O - P | Power supply for air outlet damper position sensor signal | Power switch ON (IG) | 4.5 to 5.5 V |
| S5TP (A7-13) - SGTP (A7-14) | P - LG | Power supply for air mix damper position sensor signal | Power switch ON (IG) | 4.5 to 5.5 V |
| IG (A8-5) - GND (A8-1) | B - W-B | Power switch signal | Power switch control OFF | 0 V |
| IG (A8-5) - GND (A8-1) | B - W-B | Power switch signal | Power switch control ON (ACC) | 10 to 14 V |
| +B (A8-6) - GND (A8-1) | Y - W-B | Back-up power source | Always | 10 to 14 V |
| MPX+ (A8-3) - GND (A8-1) | B - W-B | Terminal for BEAN | Engine idling after engine warmed up | Pulse generation |
| MPX2+ (A8-11) - GND (A8-1) | GR - W-B | Terminal for BEAN | Engine idling after engine warmed up | Pulse generation |
| GND (A8-1) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 Ω |
| BLW (A8-2) - GND (A8-1) | W - W-B | Blower switch signal | Power switch ON (IG) Blower switch ON (IG) | Pulse generation (see waveform 1) |
| S5TS (A7-12) - TS (A7-21) | GR - BR | Solar sensor signal | Power switch ON (IG) | 0.8 to 4.3 V |
| HR (A8-7) - GND (A8-1) | B - W-B | Blower switch signal | Power switch ON (IG) Blower switch: OFF | 10 to 14 V |
| HR (A8-7) - GND (A8-1) | B - W-B | Blower switch signal | Power switch ON (IG) Blower switch: ON | Below 1 V |
| TR (A7-8) - SGTR (A7-22) | B - W | Room temperature sensor signal | Power switch ON (IG) Cabin temperature: 25°C (77°F) | 1.8 to 2.2 V |
| TR (A7-8) - SGTR (A7-22) | B - W | Room temperature sensor signal | Power switch ON (IG) Cabin temperature: 40°C (104°F) | 1.2 to 1.6 V |
| SGTR (A7-22) - Body ground | W - Body ground | Ground for room temperature sensor | Always | Below 1 Ω |
| ST1 (A7-2) - SGST (A7-15) | BR - G | Steering pad switch signal | Power switch ON (IG) Steering pad switch: Fr. DEF | Below 0.3 V |
| ST1 (A7-2) - SGST (A7-15) | BR - G | Steering pad switch signal | Power switch ON (IG) Steering pad switch: Rr. DEF | 0.8 to 1.5 V |
| ST1 (A7-2) - SGST (A7-15) | BR - G | Steering pad switch signal | Power switch ON (IG) Steering pad switch: Recirculation/Fresh | 2 to 2.9 V |
| ST1 (A7-2) - SGST (A7-15) | BR - G | Steering pad switch signal | Power switch ON (IG) Steering pad switch: OFF | Above 4.6 V |
| ST2 (A7-1) - SGST (A7-15) | LG - G | Steering pad switch signal | Power switch ON (IG) Steering pad switch: AUTO | Below 0.3 V |
| ST2 (A7-1) - SGST (A7-15) | LG - G | Steering pad switch signal | Power switch ON (IG) Steering pad switch: TEMP+ | 0.8 to 1.5 V |
| ST2 (A7-1) - SGST (A7-15) | LG - G | Steering pad switch signal | Power switch ON (IG) Steering pad switch: TEMP- | 2 to 2.9 V |
| ST2 (A7-1) - SGST (A7-15) | LG - G | Steering pad switch signal | Power switch ON (IG) Steering pad switch: OFF | Above 4.6 V |
| SGST (A7-15) - Body ground | G - Body ground | Ground for steering pad switch | Always | Below 1 V |
| PSW (A7-6) - GND (A8-1) | R - W-B | Pressure switch signal | Power switch ON (IG) Refrigerant pressure: Normal | Below 1 V |
| PSW (A7-6) - GND (A8-1) | R - W-B | Pressure switch signal | Power switch ON (IG) Refrigerant pressure: More than 1,520 kPa (15.5 kgf/cm 2,220 psi) | 10 to 14 V |
| RH (A7-9) - GND (A8-1) | R - W-B | Humidity sensor signal | Power switch ON (IG) Room humidity: 40% | 2 V |
| RH (A7-9) - GND (A8-1) | R - W-B | Humidity sensor signal | Power switch ON (IG) Room humidity: 60% | 2.5 V |
| S5RM (A7-10) - GND (A8-1) | G - W-B | Power supply for humidity sensor | Power switch ON (IG) | 4.5 to 5.5 V |
| PTC (A7-17) - GND (A8-1) | P - W-B | PTC heater signal | Power switch ON (IG) Temperature switch: Max. HOT Coolant temperature: Below 55°C (131°F) Blower switch: OFF | Below 1 V |
| PTC (A7-17) - GND (A8-1) | P - W-B | PTC heater signal | Power switch ON (IG) Temperature switch: Max. HOT Coolant temperature: Below 55°C (131°F) Blower switch: LO | 10 to 14 V |
| HT-1 (A7-26) - GND (A8-1) | BR - W-B | PTC heater signal | Power switch ON (IG) Temperature switch: Max. HOT Coolant temperature: Below 55°C (131°F) Blower switch: OFF | Below 1 V |
| HT-1 (A7-26) - GND (A8-1) | BR - W-B | PTC heater signal | Power switch ON (IG) Temperature switch: Max. HOT Coolant temperature: Below 55°C (131°F) Blower switch: LO | 10 to 14 V |
| HT-2 (A7-25) - GND (A8-1) | L - W-B | PTC heater signal | Power switch ON (IG) Temperature switch: Max. HOT Coolant temperature: Below 55°C (131°F) Blower switch: OFF | Below 1 V |
| HT-2 (A7-25) - GND (A8-1) | L - W-B | PTC heater signal | Power switch ON (IG) Temperature switch: Max. HOT Coolant temperature: Below 55°C (131°F) Blower switch: LO | 10 to 14 V |
| IDH (A8-18) - GND (A8-1) | V - W-B | DC/DC converter signal | Power switch ON (IG) (Voltage normal) | 10 to 14 V |
| IDH (A8-18) - GND (A8-1) | V - W-B | DC/DC converter signal | Power switch ON (IG) (Over voltage) | Below 1 V |
![]() |
Using an oscilloscope, measure the waveform 1.
| Item | Content |
| Symbols (Terminal No.) | BLW (A8-2) - GND (A8-1) |
| Tool Setting | 2 V/DIV., 500 msec./DIV. |
| Condition | Power switch ON (IG), Blower switch LO |