Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM

AIR CONDITIONING SYSTEM > Heater Relay Circuit

for Preparation Click here


DESCRIPTION

The heater relay is turned on by signals from the air conditioning amplifier. It supplies power to the blower motor controller.

WIRING DIAGRAM


E125218E03


INSPECTION PROCEDURE

1.INSPECT FUSE (GAUGE, HTR)
  1. Remove the GAUGE fuse from the driver side junction block.

  1. Remove the HTR H-fuse from the engine room junction block.

  1. Measure the resistance of the fuses.

    Standard resistance:
    Below 1 Ω



NG
REPLACE FUSE
OK


2.INSPECT HEATER RELAY (Marking: HTR)


    E032993
  1. Remove the heater relay from the driver side junction block.

  1. Measure the resistance of the relay.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 5
    Below 1 Ω
    (When battery voltage applied to terminals 1 and 2)
    3 - 4
    Below 1 Ω
    3 - 5
    10 kΩ or higher
    (When battery voltage applied to terminals 1 and 2)



NG
REPLACE HEATER RELAY
OK


3.CHECK WIRE HARNESS (BATTERY - AIR CONDITIONING AMPLIFIER)


    E127522E03
  1. Disconnect the A8 amplifier connector.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    A8-7 (HR) - Body ground
    Power switch ON (IG)
    10 to 14 V



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK


4.CHECK AIR CONDITIONING AMPLIFIER (HR VOLTAGE)


    E127522E03
  1. Remove the air conditioning amplifier with connectors still connected.

  1. Measure the voltage of the connector.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    A8-7 (HR) - Body ground
    Power switch OFF
    Blower switch position ON
    Below 1 V
    A8-7 (HR) - Body ground
    Power switch ON (IG)
    Blower switch position ON
    Below 1 V
    A8-7 (HR) - Body ground
    Power switch ON (IG)
    Blower switch position OFF
    10 to 14 V



NG
REPLACE AIR CONDITIONING AMPLIFIER
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE