AIR CONDITIONING SYSTEM > DATA LIST / ACTIVE TEST |
| READ DATA LIST |
Connect Techstream to the DLC3.
Turn the power switch ON (IG) and turn Techstream ON.
Read the DATA LIST by following the prompts on the tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature Sensor | Room temperature sensor / min.: -6.5°C (20.3°F) max.: 57.25°C (135.05°F) | Actual room temperature is displayed | Open in the circuit: -6.5°C (20.3°F) Short in the circuit: 57.25°C (135.05°F) |
| Ambient Temp Sensor | Ambient temperature sensor / min.: -23.3°C (-9.94°F) max.: 65.95°C (150.71°F) | Actual ambient temperature is displayed | Open in the circuit: -23.3°C (-9.94°F) Short: in the circuit: 65.95°C (150.71°F) |
| Adjusted Ambient Temp | Adjusted ambient temperature / min.: -30.8°C (-23.44°F) max.: 50.8°C (123.44°F) | - | - |
| Evaporator Temp Sensor | Evaporator temperature sensor / min.: -29.7°C (-21.46°F) max.: 59.55°C (139.19°F) | Actual evaporator temperature is displayed | Open in the circuit: -29.7°C (-21.46°F) Short in the circuit: 59.55°C (139.19°F) |
| Solar Sensor (D side) | Solar sensor (Driver side) / min.: 0 max.: 255 | Increases as brightness increases | Open in the circuit: 0 Short in the circuit: 255 |
| Engine Coolant Temp | Engine coolant temperature / min.: 1.3°C (34.34°F) max.: 90.55°C (194.99°F) | Actual engine coolant temperature is displayed while the engine is warmed up | - |
| Set Temperature (D side) | Set temperature (Driver side) / min.: 0 max.: 255 | The same contents as a setting temperature display part are displayed | - |
| Air Mix Damper Position (D) | Air mix damper position (Driver side) / min.: -14% max.: 113.5% | Damper is at "MAX. COOL": -10.0% Damper is at "MAX. HOT": 100.0% or 71.0% | - |
| Air Outlet Damper Position | Air outlet damper position / min.: -14% max.: 113.5% | Damper is at "FACE": -10.0% Damper is at "FACE/FOOT": 12.0% Damper is at "FOOT" (Manual): 33.5% or 69.0% Damper is at "FOOT" (Auto): 49.0% or 69.0 % Damper is at "FACE/DEF": 69.0% or 95.0% Damper is at "DEF": 110.0% | Open in the circuit: 50.0% |
| Air Inlet Damper Position | Air inlet damper position / min.: -14% max.: 113.5% | Damper is at "RECIRCULATION": -1.0% Damper is at "FRESH": 110.0% Damper is at "HALF-RECIRCULATION": 20.0 to 102.0% | Open in the circuit: 50.0% |
| Air Mix Damper Target (D) | Air mix damper target position (Driver side) / min.: -14% max.: 113.5% | Damper is at "MAX. COOL": -10.0% Damper is at "MAX. HOT": 100.0% or 71.0% | - |
| Air Inlet Damper Target | Air inlet damper target position / min.: -14% max.: 113.5% | Damper is at "RECIRCULATION": -1.0% Damper is at "FRESH": 110.0% Damper is at "HALF-RECIRCULATION": 20.0 to 102.0% | Open in the circuit: 50.0% |
| Air Outlet Damper Target | Air outlet damper target position / min.: -14% max.: 113.5% | Damper is at "FACE": -10.0% Damper is at "FACE/FOOT": 12.0% Damper is at "FOOT" (Manual): 33.5% or 69.0% Damper is at "FOOT" (Auto): 49.0% or 69.0 % Damper is at "FACE/DEF": 69.0% or 95.0% Damper is at "DEF": 110.0% | Open in the circuit: 50.0% |
| Hand Free Telephone | Handsfree telephone / OFF, ON | - | - |
| Blower Motor Speed Level | Blower motor speed level / min.: Level 0 max.: 31 | Increases in the range between 0 and 31 as the speed increases | - |
| Humidity Sensor | Humidity sensor / min.: 0% max.: 100% | Actual room humidity is displayed | - |
| Compressor Speed | Compressor speed / min.: 0 rpm max.: 65,535 rpm | Displays actual rotation speed in the range between 0 rpm and 7,500 rpm | - |
| Compressor Target Speed | Compressor target speed / min.: 0 rpm max.: 65,535 rpm | Displays target rotation speed in the range between 0 rpm and 7,500 rpm | - |
| Number of Trouble Code | Number of trouble codes / min.: 0 max.: 255 | Number of DTCs will be displayed | - |
| Shift Set Temperature | Shift set temperature / +2C, +1C, NORMAL, -1C, -2C | Customized value will be displayed | - |
| Air Inlet Mode | Air inlet mode / AUTO, MANUAL | Customized value will be displayed | - |
| Compressor Mode | Compressor mode / AUTO, MANUAL | Customized value will be displayed | - |
| Compressor/DEF Mode | Compressor/DEF operation mode / LINK, NORMAL | Customized value will be displayed | - |
| Foot/DEF Auto Mode | Foot/DEF auto mode / ON, OFF | Customized value will be displayed | - |
| Foot/DEF Auto Blow Up | Foot/DEF automatic blower up function / ON, OFF | Customized value will be displayed | - |
| Foot Air Leak | Foot air leak / ON, OFF | Customized value will be displayed | - |
| Ambient Temperature Shift | Ambient temperature shift / +3C, +2C, +1C, NORMAL, -1C, 2C, 3C | Customized value will be displayed | - |
| PERFORM ACTIVE TEST |
Connect Techstream to the DLC3.
Turn the power switch ON (IG) and turn Techstream ON.
Perform the ACTIVE TEST by following the prompts on the tester.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor | min.: 0 max.: 31 | - |
| Air Mix Damper (D Side) | Air mix damper (Driver side) | min.: -14% max.: 113.5% | - |
| Air Outlet Damper Position (D Side) | Air outlet damper position (Driver side) | min.: -14% max.: 113.5% | - |
| Air Inlet Damper Position (Linear) | Air inlet damper position (linear) | min.: -14% max.: 113.5% | - |
| Compressor Target Speed | Compressor target speed | min.: 0 max.: 65535 | - |
| Defogger Relay (Rear) | Defogger relay (Rear) | OFF, ON | - |
| Water Pump | Water pump | OFF, ON | - |
| Electrical Fan | Electrical fan | OFF, ON | - |
| Defogger Relay (Rear) | Defogger relay (Rear) | OFF, ON | - |