Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM

AIR CONDITIONING SYSTEM > DATA LIST / ACTIVE TEST

for Preparation Click here



READ DATA LIST

HINT:
Using Techstream to read the Data List allows the values or states of switches, sensors, actuators, and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

  1. Connect Techstream to the DLC3.

  2. Turn the power switch ON (IG) and turn Techstream ON.

  3. Read the DATA LIST by following the prompts on the tester.

    Air conditioning amplifier 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Room temperature sensor /
    min.: -6.5°C (20.3°F)
    max.: 57.25°C (135.05°F)
    Actual room temperature is displayed
    Open in the circuit: -6.5°C (20.3°F)
    Short in the circuit: 57.25°C (135.05°F)
    Ambient Temp Sensor
    Ambient temperature sensor /
    min.: -23.3°C (-9.94°F)
    max.: 65.95°C (150.71°F)
    Actual ambient temperature is displayed
    Open in the circuit: -23.3°C (-9.94°F)
    Short: in the circuit: 65.95°C (150.71°F)
    Adjusted Ambient Temp
    Adjusted ambient temperature /
    min.: -30.8°C (-23.44°F)
    max.: 50.8°C (123.44°F)
    -
    -
    Evaporator Temp Sensor
    Evaporator temperature sensor /
    min.: -29.7°C (-21.46°F)
    max.: 59.55°C (139.19°F)
    Actual evaporator temperature is displayed
    Open in the circuit: -29.7°C (-21.46°F)
    Short in the circuit: 59.55°C (139.19°F)
    Solar Sensor (D side)
    Solar sensor (Driver side) /
    min.: 0 max.: 255
    Increases as brightness increases
    Open in the circuit: 0
    Short in the circuit: 255
    Engine Coolant Temp
    Engine coolant temperature /
    min.: 1.3°C (34.34°F)
    max.: 90.55°C (194.99°F)
    Actual engine coolant temperature is displayed while the engine is warmed up
    -
    Set Temperature (D side)
    Set temperature (Driver side) /
    min.: 0 max.: 255
    The same contents as a setting temperature display part are displayed
    -
    Air Mix Damper Position (D)
    Air mix damper position (Driver side) / min.: -14% max.: 113.5%
    Damper is at "MAX. COOL":
    -10.0%
    Damper is at "MAX. HOT":
    100.0% or 71.0%
    -
    Air Outlet Damper Position
    Air outlet damper position /
    min.: -14% max.: 113.5%
    Damper is at "FACE": -10.0%
    Damper is at "FACE/FOOT": 12.0%
    Damper is at "FOOT" (Manual): 33.5% or 69.0%
    Damper is at "FOOT" (Auto): 49.0% or 69.0 %
    Damper is at "FACE/DEF": 69.0% or 95.0%
    Damper is at "DEF": 110.0%
    Open in the circuit: 50.0%
    Air Inlet Damper Position
    Air inlet damper position /
    min.: -14% max.: 113.5%
    Damper is at "RECIRCULATION": -1.0%
    Damper is at "FRESH": 110.0%
    Damper is at "HALF-RECIRCULATION": 20.0 to 102.0%
    Open in the circuit: 50.0%
    Air Mix Damper Target (D)
    Air mix damper target position (Driver side) /
    min.: -14% max.: 113.5%
    Damper is at "MAX. COOL": -10.0%
    Damper is at "MAX. HOT": 100.0% or 71.0%
    -
    Air Inlet Damper Target
    Air inlet damper target position /
    min.: -14% max.: 113.5%
    Damper is at "RECIRCULATION": -1.0%
    Damper is at "FRESH": 110.0%
    Damper is at "HALF-RECIRCULATION": 20.0 to 102.0%
    Open in the circuit: 50.0%
    Air Outlet Damper Target
    Air outlet damper target position /
    min.: -14% max.: 113.5%
    Damper is at "FACE": -10.0%
    Damper is at "FACE/FOOT": 12.0%
    Damper is at "FOOT" (Manual): 33.5% or 69.0%
    Damper is at "FOOT" (Auto): 49.0% or 69.0 %
    Damper is at "FACE/DEF": 69.0% or 95.0%
    Damper is at "DEF": 110.0%
    Open in the circuit: 50.0%
    Hand Free Telephone
    Handsfree telephone / OFF, ON
    -
    -
    Blower Motor Speed Level
    Blower motor speed level /
    min.: Level 0 max.: 31
    Increases in the range between 0 and 31 as the speed increases
    -
    Humidity Sensor
    Humidity sensor /
    min.: 0% max.: 100%
    Actual room humidity is displayed
    -
    Compressor Speed
    Compressor speed /
    min.: 0 rpm max.: 65,535 rpm
    Displays actual rotation speed in the range between 0 rpm and 7,500 rpm
    -
    Compressor Target Speed
    Compressor target speed /
    min.: 0 rpm max.: 65,535 rpm
    Displays target rotation speed in the range between 0 rpm and 7,500 rpm
    -
    Number of Trouble Code
    Number of trouble codes /
    min.: 0 max.: 255
    Number of DTCs will be displayed
    -
    Shift Set Temperature
    Shift set temperature / +2C, +1C,
    NORMAL, -1C, -2C
    Customized value will be displayed
    -
    Air Inlet Mode
    Air inlet mode / AUTO, MANUAL
    Customized value will be displayed
    -
    Compressor Mode
    Compressor mode / AUTO, MANUAL
    Customized value will be displayed
    -
    Compressor/DEF Mode
    Compressor/DEF operation mode / LINK, NORMAL
    Customized value will be displayed
    -
    Foot/DEF Auto Mode
    Foot/DEF auto mode / ON, OFF
    Customized value will be displayed
    -
    Foot/DEF Auto Blow Up
    Foot/DEF automatic blower up function / ON, OFF
    Customized value will be displayed
    -
    Foot Air Leak
    Foot air leak / ON, OFF
    Customized value will be displayed
    -
    Ambient Temperature Shift
    Ambient temperature shift / +3C, +2C, +1C, NORMAL, -1C, 2C, 3C
    Customized value will be displayed
    -


PERFORM ACTIVE TEST

HINT:
Using Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

  1. Connect Techstream to the DLC3.

  2. Turn the power switch ON (IG) and turn Techstream ON.

  3. Perform the ACTIVE TEST by following the prompts on the tester.

    Air conditioning amplifier 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    min.: 0 max.: 31
    -
    Air Mix Damper (D Side)
    Air mix damper (Driver side)
    min.: -14% max.: 113.5%
    -
    Air Outlet Damper Position (D Side)
    Air outlet damper position (Driver side)
    min.: -14% max.: 113.5%
    -
    Air Inlet Damper Position (Linear)
    Air inlet damper position (linear)
    min.: -14% max.: 113.5%
    -
    Compressor Target Speed
    Compressor target speed
    min.: 0 max.: 65535
    -
    Defogger Relay (Rear)
    Defogger relay (Rear)
    OFF, ON
    -
    Water Pump
    Water pump
    OFF, ON
    -
    Electrical Fan
    Electrical fan
    OFF, ON
    -
    Defogger Relay (Rear)
    Defogger relay (Rear)
    OFF, ON
    -