DTC B1411 Room Temperature Sensor Circuit |
| DTC No. | Detection Condition | Trouble Area |
| B1411 | Open or short in room temperature sensor circuit |
|

| 1.READ VALUE OF TECHSTREAM |
Connect Techstream to DLC3.
Turn the power switch ON (IG) and turn Techstream ON.
Select the item below in the Data List, and read the display on Techstream.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Room Temperature Sensor | Room temperature sensor / Open in the circuit: min.: -6.5°C (20.3°F) max.: 57.25°C (135.05°F) | Actual room temperature is displayed | Open in the circuit: -6.5°C (20.3°F) Short in the circuit: 57.25°C (135.05°F) |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK AIR CONDITIONING AMPLIFIER (TR VOLTAGE) |
![]() |
Remove the air conditioning amplifier with connectors still connected.
Measure the voltage of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| A7-8 (TR) - A7-22 (SGTR) | Power switch ON (IG) at 25°C (77°F) | 1.8 to 2.2 V |
| A7-8 (TR) - A7-22 (SGTR) | Power switch ON (IG) at 40°C (104°F) | 1.2 to 1.6 V |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 3.INSPECT ROOM TEMPERATURE SENSOR |
![]() |
Remove the room temperature sensor.
Measure the resistance of the sensor.
| Tester Connection | Condition | Specified Condition |
| 1 (THR) - 2 (GND) | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 1 (THR) - 2 (GND) | 15°C (59°F) | 2.45 to 2.88 kΩ |
| 1 (THR) - 2 (GND) | 20°C (68°F) | 1.95 to 2.30 kΩ |
| 1 (THR) - 2 (GND) | 25°C (77°F) | 1.60 to 1.80 kΩ |
| 1 (THR) - 2 (GND) | 30°C (86°F) | 1.28 to 1.47 kΩ |
| 1 (THR) - 2 (GND) | 35°C (95°F) | 1.00 to 1.22 kΩ |
| 1 (THR) - 2 (GND) | 40°C (104°F) | 0.80 to 1.00 kΩ |
| 1 (THR) - 2 (GND) | 45°C (113°F) | 0.65 to 0.85 kΩ |
| 1 (THR) - 2 (GND) | 50°C (122°F) | 0.50 to 0.70 kΩ |
| 1 (THR) - 2 (GND) | 55°C (131°F) | 0.44 to 0.60 kΩ |
| 1 (THR) - 2 (GND) | 60°C (140°F) | 0.36 to 0.50 kΩ |
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the A9 sensor connector.
Disconnect the A7 amplifier connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| A7-8 (TR) - A9-1 (THR) | Below 1 Ω |
| A7-22 (SGTR) - A9-2 (GND) | Below 1 Ω |
| A7-8 (TR) - Body ground | 10 kΩ or higher |
| A7-22 (SGTR) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||