Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1431    Air Mix Damper Position Sensor Circuit (Passenger Side)

for Preparation Click here


DESCRIPTION

E109300E21
This sensor detects the position of the air mix control servo motor (air mix damper) and sends the appropriate signals to the air conditioning amplifier. The position sensor is built into the air mix control servo motor. The position sensor resistance changes as the air mix control servo motor arm moves.
It outputs voltage (5 V) that is input to terminal 1 (VZ) and terminal 3 (PT) via the variable resistor, and then to the air conditioning amplifier. The air conditioning amplifier reads the arm position with the input voltage from the position sensor.

DTC No.
Detection Condition
Trouble Area
B1431
Open or short in power source circuit in air mix damper position sensor circuit.
  1. Air mix control servo motor (air mix damper position sensor)
  2. Wire harness between air mix control servo motor and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E125210E01


INSPECTION PROCEDURE

1.READ VALUE OF TECHSTREAM
  1. Connect Techstream to DLC3.

  1. Turn the power switch ON (IG) and turn Techstream ON.

  1. Select the item below in the Data List, and read the display on Techstream.

    Air conditioning amplifier 
    Item
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    Air Mix Damper Position (D)
    Air mix damper position (Driver side) / min.: -14% max.: 113.5%
    Damper is at "MAX. COOL": -10.0%
    Damper is at "MAX. HOT": 100.0% or 71.0%
    -
    Air Mix Damper Target (D)
    Air mix damper target position (Driver side) / min.: -14% max.: 113.5%
    Damper is at "MAX. COOL": -10.0%
    Damper is at "MAX. HOT": 100.0% or 71.0%
    -

    OK:
    The displayed is as specified in the normal condition.


    Result 
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2.CHECK AIR CONDITIONING AMPLIFIER (TP VOLTAGE)
I041186E05
  1. Remove the air conditioning amplifier with its connectors still connected.

  1. Change the set temperature to activate the air mix servo motor.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    A7-20 (TP) - A7-14 (SGTP)
    Power switch ON (IG)
    MAX. HOT position
    0.97 to 1.03 V
    A7-20 (TP) - A7-14 (SGTP)
    Power switch ON (IG)
    MAX. COOL position
    3.97 to 4.03 V

    HINT:
    As the set temperature increases, the voltage decreases gradually without interruption.

    Result 
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


3.INSPECT AIR MIX CONTROL SERVO MOTOR
E068754E01
E127530E01
  1. Remove the air mix control servo motor.

  1. Measure the resistance of the servo motor.

    Standard resistance:
    Tester Connection
    Specified Condition
    A15-1 (VZ) - A15-2 (GND)
    4.2 to 7.8 kΩ

  1. Measure the resistance of the servo motor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A15-3 (PT) - A15-2 (GND)
    MAX. COOL Position
    3.6 to 6.7 kΩ
    A15-3 (PT) - A15-2 (GND)
    MAX. HOT Position
    0.8 to 1.6 kΩ

HINT:
  1. Refer to the operation procedure for air mix control servo motor .
  1. As the air mix control servo motor moves from the COOL position to HOT position, the resistance decreases gradually without interruption.



NG
REPLACE AIR MIX CONTROL SERVO MOTOR
OK


4.CHECK WIRE HARNESS (AIR MIX CONTROL SERVO MOTOR - AIR CONDITIONING AMPLIFIER)
E125233E03
  1. Disconnect the A15 servo connector.

  1. Disconnect the A7 amplifier connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    A7-20 (TP) - A15-3 (PT)
    Below 1 Ω
    A7-14 (SGTP) - A15-2 (GND)
    Below 1 Ω
    A7-13 (S5TP) - A15-1 (VZ)
    Below 1 Ω
    A7-20 (TP) - Body ground
    10 kΩ or higher
    A7-14 (SGTP) - Body ground
    10 kΩ or higher
    A7-13 (S5TP) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER