DTC B1432 Air Inlet Damper Position Sensor Circuit |

| DTC No. | Detection Condition | Trouble Area |
| B1432 | Open or short in power source circuit in air inlet damper position sensor circuit. |
|

| 1.READ VALUE OF TECHSTREAM |
Connect Techstream to DLC3.
Turn the power switch ON (IG) and turn Techstream ON.
Select the item below in the Data List, and read the display on Techstream.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Air Inlet Damper Position | Air inlet damper position / min.: -14% max.: 113.5% | Damper is at "RECIRCULATION": -1.0% Damper is at "FRESH": 110.0% Damper is at "HALF-RECIRCULATION": 20.0 to 102.0% | Open in the circuit: 50.0% |
| Air Inlet Damper Target | Air inlet damper target position / min.: -14% max.: 113.5% | Damper is at "RECIRCULATION": -1.0% Damper is at "FRESH": 110.0% Damper is at "HALF-RECIRCULATION": 20.0 to 102.0% | Open in the circuit: 50.0% |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK AIR CONDITIONING AMPLIFIER (TPI VOLTAGE) |
![]() |
Remove the air conditioning amplifier with connectors still connected.
Change the set REC / FRS to activate the air inlet servo motor.
Measure the voltage of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| A7-19 (TPI) - A7-4 (SGTPI) | Power switch ON (IG) RECIRC position | 3.5 to 4.5 V |
| A7-19 (TPI) - A7-4 (SGTPI) | Power switch ON (IG) FRESH position | 0.5 to 1.8 V |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 3.INSPECT AIR INLET CONTROL SERVO MOTOR |
![]() |
Remove the air inlet control servo motor.
Measure the resistance of the servo motor.
| Tester Connection | Specified Condition |
| A14-1 (VZ) - A14-2 (GND) | 4.2 to 7.8 kΩ |
![]() |
Measure the resistance of the servo motor.
| Tester Connection | Condition | Specified Condition |
| A14-3 (PT) - A14-2 (GND) | RECIRCULATION position | 3.4 to 6.2 kΩ |
| A14-3 (PT) - A14-2 (GND) | FRESH position | 0.6 to 1.1 kΩ |
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (AIR INLET CONTROL SERVO MOTOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the A14 servo connector.
Disconnect the A7 amplifier connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| A7-19 (TPI) - A14-3 (PT) | Below 1 Ω |
| A7-4 (SGTPI) - A14-2 (GND) | Below 1 Ω |
| A7-3 (S5TPI) - A14-1 (VZ) | Below 1 Ω |
| A7-19 (TPI) - Body ground | 10 kΩ or higher |
| A7-4 (SGTPI) - Body ground | 10 kΩ or higher |
| A7-3 (S5TPI) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||