Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1441    Air Mix Damper Control Servo Motor Circuit (Passenger Side)

for Preparation Click here


DESCRIPTION

The air mix control servo motor (air mix damper servo) is controlled by the air conditioning amplifier.
The air mix control servo motor moves the air mix damper by rotating (normal, reverse) the motor with electrical power from the air conditioning amplifier.
This adjusts the mix ratio of the air that passes through the evaporator and heater core and controls the airflow temperature. Air flow temperature changes when moving the air mix damper to the target point. The target point can be detected with the air mix damper position sensor.

DTC No.
Detection Condition
Trouble Area
B1441
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates air mix servo motor.
  1. Air mix control servo motor
  2. Wire harness between air mix control servo motor and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E125211E01


INSPECTION PROCEDURE

1.READ VALUE OF TECHSTREAM
  1. Connect Techstream to DLC3.

  1. Turn the power switch ON (IG) and turn Techstream ON.

  1. Select the item below in the Data List, and read the display on Techstream.


Air conditioning amplifier 
Item
Measurement Item / Display (Range)
Normal Condition
Diagnostic Note
Air Mix Damper Position (D)
Air mix damper position (Driver side) / min.: -14% max.: 113.5%
Damper is at "MAX. COOL": -10.0%
-
Air Mix Damper Target (D)
Air mix damper target position (Driver side) /
min.: -14% max.: 113.5%
Damper is at "MAX. COOL": -10.0%
-

OK:
When the target position is at the "MAX. COOL" (-10.0%), the actual opening angle is 19.0% or less.


Result 
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C


B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2.READ VALUE OF TECHSTREAM
  1. Connect Techstream to DLC3.

  1. Turn the power switch ON (IG) and turn Techstream ON.

  1. Select the item below in the Data List, and read the display on Techstream.


Air conditioning amplifier 
Item
Measurement Item / Display (Range)
Normal Condition
Diagnostic Note
Air Mix Damper Position (D)
Air mix damper position (Driver side) / min.: -14% max.: 113.5%
Damper is at "MAX. HOT": 100.0% or 71.0%
-
Air Mix Damper Target (D)
Air mix damper target position (Driver side) /
min.: -14% max.: 113.5%
Damper is at "MAX. HOT": 100.0% or 71.0%
-

OK:
When the target position is at the "MAX. HOT" (100.0%), the actual opening angle is 81.0% or more.


Result 
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C


B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


3.INSPECT AIR MIX CONTROL SERVO MOTOR
E127533E01
  1. Remove the air mix control servo motor.

  1. Connect the battery's positive (+) lead to terminal 5 and negative (-) lead to terminal 4, then check that lever turns to "MAX. HOT" position smoothly.

  1. Measure the resistance of the servo motor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A15-3 (PT) - A15-2 (GND)
    MAX. HOT position
    0.8 to 1.6 kΩ

  1. Connect the battery's positive (+) lead to terminal 4 and negative (-) lead to terminal 5, then check that lever turns to "MAX. COOL" position smoothly.

  1. Measure the resistance of the servo motor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A15-3 (PT) - A15-2 (GND)
    MAX. COOL position
    3.6 to 6.7 kΩ



NG
REPLACE AIR MIX CONTROL SERVO MOTOR
OK


4.CHECK WIRE HARNESS (AIR MIX CONTROL SERVO MOTOR - AIR CONDITIONING AMPLIFIER)
E125234E01
  1. Disconnect the A15 servo connector.

  1. Disconnect the A8 amplifier connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    A8-19 (AMC) - A15-4 (MCOOL)
    Below 1 Ω
    A8-17 (AMH) - A15-5 (MHOT)
    Below 1 Ω
    A8-19 (AMC) - Body ground
    10 kΩ or higher
    A8-17 (AMH) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER