DTC B1442 Air Inlet Damper Control Servo Motor Circuit |
| DTC No. | Detection Condition | Trouble Area |
| B1442 | Air outlet damper position sensor valve does not change even if air conditioning amplifier operated air outlet damper control servo motor. |
|

| 1.READ VALUE OF TECHSTREAM |
Connect Techstream to DLC3.
Turn the power switch ON and turn Techstream ON.
Select the item below in the Data List, and read the display on Techstream.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Air Inlet Damper Position | Air inlet damper position / min.: -14% max.: 113.5% | Damper is at "RECIRCULATION": -1.0% Damper is at "HALF-RECIRCULATION": 20.0 to 102.0% | Open in the circuit: 50.0% |
| Air Inlet Damper Target | Air inlet damper target position / min.: -14% max.: 113.5% | Damper is at "RECIRCULATION": -1.0% Damper is at "HALF-RECIRCULATION": 20.0 to 102.0% | Open in the circuit: 50.0% |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.READ VALUE OF TECHSTREAM |
Connect Techstream to DLC3.
Turn the power switch ON (IG) and turn Techstream ON.
Select the item below in the Data List, and read the display on Techstream.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Air Inlet Damper Position | Air inlet damper position / min.: -14% max.: 113.5% | Damper is at "FRESH": 110.0% Damper is at "HALF-RECIRCULATION": 20.0 to 102.0% | Open in the circuit: 50.0% |
| Air Inlet Damper Target | Air inlet damper target position / min.: -14% max.: 113.5% | Damper is at "FRESH": 110.0% Damper is at "HALF-RECIRCULATION": 20.0 to 102.0% | Open in the circuit: 50.0% |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 3.INSPECT AIR INLET CONTROL SERVO MOTOR |
![]() |
Remove the damper air inlet servo motor.
Connect the battery's positive (+) lead to terminal 5 and negative (-) lead to terminal 4 then check that the lever turns to "FRESH" position smoothly.
Measure the resistance of the servo motor.
| Tester Connection | Condition | Specified Condition |
| A14-3 (PT) - A14-2 (GND) | FRESH position | 0.6 to 1.1 kΩ |
Connect the battery's positive (+) lead to terminal 4 and negative (-) lead to terminal 5 then check that the lever turns to "RECIRCULATION" position smoothly.
Measure the resistance of the servo motor.
| Tester Connection | Condition | Specified Condition |
| A14-3 (PT) - A14-2 (GND) | RECIRCULATION position | 3.4 to 6.2 kΩ |
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (AIR INLET CONTROL SERVO MOTOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the A14 servo connector.
Disconnect the A8 amplifier connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| A8-22 (AIR) - A14-4 (Mrec) | Below 1 Ω |
| A8-23 (AIF) - A14-5 (Mfrs) | Below 1 Ω |
| A8-22 (AIR) - Body ground | 10 kΩ or higher |
| A8-23 (AIF) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||