DTC    B1443    Air Outlet Damper Control Servo Motor Circuit

for Preparation Click here


DESCRIPTION

This circuit turns the servo motor and changes each damper position by receiving the signals from the air conditioning amplifier.
The air outlet damper servo switches the air outlet by rotating the motor (normal, reverse) with electrical power from the air conditioning amplifier.
When the AUTO switch is on, the air conditioning amplifier changes the mode between "FACE", "BI-LEVEL" and "FOOT" according to the temperature setting.

DTC No.
Detection Condition
Trouble Area
B1443
Air outlet damper position sensor valve does not change even if air conditioning amplifier operated air outlet damper control servo motor.
  1. Air outlet control servo motor
  2. Wire harness between air outlet control servo motor and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E125211E03


INSPECTION PROCEDURE

1.READ VALUE OF TECHSTREAM
  1. Connect Techstream to DLC3.

  1. Turn the power switch ON (IG) and Techstream ON.

  1. Select the item below in the Data List, and read the display on Techstream.

    Air conditioning amplifier 
    Item
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    Air Outlet Damper Position
    Air outlet damper position /
    min.: -14% max.: 113.5%
    Damper is at "FACE": -10.0%
    Damper is at "FACE/FOOT": 12.0%
    Damper is at "FOOT" (Manual): 33.5% or 69.0%
    Damper is at "FOOT" (Auto): 49.0% or 69.0%
    Damper is at "FACE/DEF": 69.0% or 95.0%
    Open in the circuit: 50.0%
    Air Outlet Damper Target
    Air outlet damper target position /
    min.: -14% max.: 113.5%
    Damper is at "FACE": -10.0%
    Damper is at "FACE/FOOT": 12.0%
    Damper is at "FOOT" (Manual): 33.5% or 69.0%
    Damper is at "FOOT" (Auto): 49.0% or 69.0%
    Damper is at "FACE/DEF": 69.0% or 95.0%
    Open in the circuit: 50.0%

    OK:
    When the target position is at the "FACE" (-10.0%), the actual opening angle is 19.0% or less.


    Result 
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2.READ VALUE OF TECHSTREAM
  1. Connect Techstream to DLC3.

  1. Turn the power switch ON (IG) and turn Techstream ON.

  1. Select the item below in the Data List, and read the display on Techstream.

    Air conditioning amplifier 
    Item
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    Air Outlet Damper Position
    Air outlet damper position /
    min.: -14% max.: 113.5%
    Damper is at "FACE/FOOT": 12.0%
    Damper is at "FOOT" (Manual): 33.5% or 69.0%
    Damper is at "FOOT" (Auto): 49.0% or 69.0%
    Damper is at "FACE/DEF": 69.0% or 95.0%
    Damper is at "DEF": 110.0%
    Open in the circuit: 50.0%
    Air Outlet Damper Target
    Air outlet damper target position /
    min.: -14% max.: 113.5%
    Damper is at "FACE/FOOT": 12.0%
    Damper is at "FOOT" (Manual): 33.5% or 69.0%
    Damper is at "FOOT" (Auto): 49.0% or 69.0%
    Damper is at "FACE/DEF": 69.0% or 95.0%
    Damper is at "DEF": 110.0%
    Open in the circuit: 50.0%

    OK:
    When the target position is at the "DEF" (110.0%), the actual opening angle is 81.0% or more.


    Result 
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


3.INSPECT AIR OUTLET CONTROL SERVO MOTOR
E127535E01
  1. Remove the air outlet control servo motor.

  1. Connect the battery's positive (+) lead to terminal 4 and negative (-) lead to terminal 5 then check that the lever turns to "FACE" position smoothly.

  1. Measure the resistance of the servo motor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A16-3 (PT) - A16-2 (GND)
    FACE position
    3.6 to 6.7 kΩ

  1. Connect the battery's positive (+) lead to terminal 5 and negative (-) lead to terminal 4 then check that the lever turn to "DEF" position smoothly.

  1. Measure the resistance of the servo motor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A16-3 (PT) - A16-2 (GND)
    DEF position
    0.6 to 1.1 kΩ



NG
REPLACE AIR OUTLET CONTROL SERVO MOTOR
OK


4.CHECK WIRE HARNESS (AIR OUTLET CONTROL SERVO MOTOR - AIR CONDITIONING AMPLIFIER)
E125234E03
  1. Disconnect the A16 servo connector.

  1. Disconnect the A8 amplifier connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    A8-16 (AOF) - A16-4 (MFACE)
    Below 1 Ω
    A8-24 (AOD) - A16-5 (MDEF)
    Below 1 Ω
    A8-16 (AOF) - Body ground
    10 kΩ or higher
    A8-24 (AOD) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER