DTC B1462 Room Humidity Sensor Circuit |
| DTC No. | Detection Condition | Trouble Area |
| B1462 | Open or short in room humidity sensor circuit |
|

| 1.READ VALUE OF TECHSTREAM |
Connect Techstream to DLC3.
Turn the power switch ON (IG) and turn Techstream ON.
Select the item below in the Data List, and read the display on Techstream.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Humidity Sensor | Humidity sensor / min.: 0% max.: 100% | Actual room humidity is displayed | - |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK AIR CONDITIONING AMPLIFIER (RH VOLTAGE) |
![]() |
Remove the air conditioning amplifier with connectors still connected.
Measure the voltage of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| A7-9 (RH) - A7-10 (S5RM) | Power switch ON (IG) at 25°C (77°F) | 1.8 to 2.2 V |
| A7-9 (RH) - A7-10 (S5RM) | Power switch ON (IG) at 40°C (104°F) | 1.2 to 1.6 V |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 3.INSPECT ROOM TEMPERATURE SENSOR (HUMIDITY SENSOR) |
![]() |
Remove the room temperature sensor.
Measure the voltage of the sensor.
|
| ||||
| OK | |
| 4.CHECK WIRE HARNESS (ROOM HUMIDITY SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the A9 sensor connector.
Disconnect the A7 amplifier connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| A7-9 (RH) - A9-3 (VO) | Below 1 Ω |
| A7-10 (S5RM) - A9-4 (S5) | Below 1 Ω |
| A7-9 (RH) - Body ground | 10 kΩ or higher |
| A7-10 (S5RM) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||