DTC    B1462    Room Humidity Sensor Circuit

for Preparation Click here


DESCRIPTION

The room humidity sensor detects room humidity. The voltage of the room humidity sensor changes in accordance with room humidity. The air conditioning amplifier reads changes in the room humidity sensor.
The room humidity sensor is integrated with room temperature sensor.

DTC No.
Detection Condition
Trouble Area
B1462
Open or short in room humidity sensor circuit
  1. Room humidity sensor (room temperature sensor)
  2. Wire harness between room humidity sensor ( room temperature sensor) and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E125205E01


INSPECTION PROCEDURE

1.READ VALUE OF TECHSTREAM
  1. Connect Techstream to DLC3.

  1. Turn the power switch ON (IG) and turn Techstream ON.

  1. Select the item below in the Data List, and read the display on Techstream.

    Air conditioning amplifier 
    Item
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    Humidity Sensor
    Humidity sensor /
    min.: 0% max.: 100%
    Actual room humidity is displayed
    -

    OK:
    The displayed is as specified in the normal condition.


    Result 
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2.CHECK AIR CONDITIONING AMPLIFIER (RH VOLTAGE)
I041186E09
  1. Remove the air conditioning amplifier with connectors still connected.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    A7-9 (RH) - A7-10 (S5RM)
    Power switch ON (IG) at 25°C (77°F)
    1.8 to 2.2 V
    A7-9 (RH) - A7-10 (S5RM)
    Power switch ON (IG) at 40°C (104°F)
    1.2 to 1.6 V

    HINT:
    As the temperature increases, the voltage decreases.

    Result 
    Result
    Proceed to
    NG
    A
    OK (Checking from the PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


3.INSPECT ROOM TEMPERATURE SENSOR (HUMIDITY SENSOR)
E127526E01
  1. Remove the room temperature sensor.

  1. Measure the voltage of the sensor.

    Standard voltage:
    at 25°C (77°F) Humidity 40%: 1.61 to 2.24 V
    at 25°C (77°F) Humidity 60%: 2.26 to 2.66 V

    HINT:
    As the humidity increases, the voltage increases (see the graph).



NG
REPLACE ROOM TEMPERATURE SENSOR
OK


4.CHECK WIRE HARNESS (ROOM HUMIDITY SENSOR - AIR CONDITIONING AMPLIFIER)
E125235E01
  1. Disconnect the A9 sensor connector.

  1. Disconnect the A7 amplifier connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    A7-9 (RH) - A9-3 (VO)
    Below 1 Ω
    A7-10 (S5RM) - A9-4 (S5)
    Below 1 Ω
    A7-9 (RH) - Body ground
    10 kΩ or higher
    A7-10 (S5RM) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER