DTC    B1476    A/C Inverter Load System Malfunction

for Preparation Click here


DESCRIPTION

The A/C inverter stops compressor control and outputs the DTC if the rotation load is too great or too small while controlling motor rotation in the A/C inverter.

HINT:
Possible reasons could be as follows: Load is low when the refrigerant gas leaks, or load is too great when refrigerant gas is excessively charged, insufficient cooling performance due to condenser fan circuit trouble, or the compressor locked up.


DTC No.
Detection Condition
Trouble Area
B1476
Motor's rotation load while the compressor is operating is too great or too small.
  1. Volume of refrigerant
  2. Electric inverter compressor (w/ motor compressor)
  3. Cooling fan circuit

NOTICE:
The A/C inverter is integrated with the inverter with converter. It is necessary to replace the PCU box if the A/C inverter (inverter with converter) needs to be replaced because the A/C inverter (inverter with converter) cannot be replaced alone.


INSPECTION PROCEDURE

1.CHECK COOLER CONDENSER ASSEMBLY
  1. Turn the power switch OFF and ON (READY).

  1. Set the A/C temperature setting to "MAX. COOL" and the blower to " LO", and turn the A/C switch ON.

  1. Check operation of the condenser fan.

    OK:
    The condenser fan rotates.



NG
INSPECT COOLING FAN SYSTEM
OK


2.CHECK HFC-134A (R134A)
I038559E03
  1. Inspect refrigerant volume.

    1. Check the sight glass of the cooler unit refrigerant liquid pipe E.

    2. Set the vehicle according to the conditions below.
      Item
      Condition
      All Doors
      Fully open
      Temperature Setting
      Max. COOL
      Blower Speed
      HI
      A/C
      ON

    3. Check the sight glass.

      Item
      Symptom
      Amount of refrigerant
      Corrective Actions
      1
      Bubbles exist
      Insufficient*
      (1) Check for gas leakage and repair if necessary
      (2) Add refrigerant until bubbles disappear
      2
      No bubbles exist (DTC B1476 is output)
      Empty, insufficient or excessive
      Refer to 3 and 4
      3
      No temperature difference between compressor inlet and outlet
      Empty or nearly empty
      (1) Check for gas leakage with gas leak detector and repair if necessary
      (2) Add refrigerant until bubbles disappear
      4
      Considerable temperature difference between compressor inlet and outlet
      Proper or excessive
      Refer to 5 and 6
      5
      Immediately after air conditioning is turned off, refrigerant remains clear
      Excessive
      (1) Discharge refrigerant
      (2) Remove air and supply proper amount of purified refrigerant
      6
      Immediately after air conditioning is turned off, refrigerant foams and then becomes clear
      Proper
      -

      HINT:
      *: Bubbles in the sight glass with room temperature higher than usual can be considered normal if cooling is sufficient.



NG
CHARGE REFRIGERANT
OK

REPLACE ELECTRIC INVERTER COMPRESSOR