Home › BODY ELECTRICAL › DOOR LOCK › FRONT DOOR LOCK

FRONT DOOR LOCK > INSPECTION

for Preparation Click here



1. INSPECT FRONT DOOR LOCK LH


B079551E05
  1. Apply battery voltage to the door lock and check operation of the door lock motor.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) →Terminal 4
    Battery negative (-) →Terminal 1
    Lock
    Battery positive (+) →Terminal 1
    Battery negative (-) →Terminal 4
    Unlock

    If the result is not as specified, replace the door lock assembly.



    B127347E01
  1. Measure the resistance of the door lock and unlock switch and position switch.

    Standard resistance :
    Door lock and unlock switch 
    Tester Connection
    Switch Condition
    Specified Condition
    7 - 9
    Lock
    Below 1 Ω
    7 - 10
    Unlock
    7 - 9
    OFF
    10 kΩ or higher
    7 - 10

    Position switch:
    Tester Connection
    Switch Condition
    Specified Condition
    7 - 8
    Lock
    Below 1 Ω
    7 - 8
    Unlock
    10 kΩ or higher

    If the result is not as specified, replace the door lock assembly.



2. INSPECT FRONT DOOR LOCK RH


B079247E07
  1. Apply battery voltage to the door lock and check operation of the door lock motor.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) →Terminal 4
    Battery negative (-) →Terminal 1
    Lock
    Battery positive (+) →Terminal 1
    Battery negative (-) →Terminal 4
    Unlock

    If the result is not as specified, replace the door lock assembly.



    B079247E07
  1. Measure the resistance of the position switch.

    Standard resistance :
    Tester Connection
    Switch Condition
    Specified Condition
    7 - 8
    Lock
    Below 1 Ω
    Unlock
    10 kΩ or higher

    If the result is not as specified, replace the door lock assembly.