Home › ENGINE › 1NZ-FXE STARTING › KEY SLOT

KEY SLOT > INSTALLATION

for Preparation Click here



1. INSTALL KEY SLOT
  1. Install the key slot with the 2 screws.



2. INSTALL NO. 3 INSTRUMENT PANEL REGISTER ASSEMBLY


B074047E04
  1. Connect the connector.

  1. Attach the claw and 5 clips to install the instrument panel register.



3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL


4. PERFORM INITIALIZATION
  1. Perform initialization (Click here).

    NOTICE:
    Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.