Home
›
ENGINE
›
1NZ-FXE EMISSION CONTROL
›
AIR FUEL RATIO SENSOR
AIR FUEL RATIO SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT AIR FUEL RATIO SENSOR
Measure the resistance between the terminals.
Standard resistance:
Tester Connection
Specified Condition
1 (HT) - 2 (+B)
1.8 to 3.4 Ω at 20°C (68°F)
2 (+B) - 4 (AF-)
10 kΩ or higher
If the result is not as specified, replace the sensor.