Home › ENGINE › 1NZ-FXE EMISSION CONTROL › HEATED OXYGEN SENSOR

HEATED OXYGEN SENSOR > INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR


A087459E03
  1. Measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 (HT) - 2 (+B)
    11 to 16 Ω at 20°C (68°F)
    1 (HT) - 4 (E)
    10 kΩ or higher

    1. If the result is not as specified, replace the sensor.