Home
›
ENGINE
›
1NZ-FXE EMISSION CONTROL
›
HEATED OXYGEN SENSOR
HEATED OXYGEN SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT HEATED OXYGEN SENSOR
Measure the resistance between the terminals.
Standard resistance:
Tester Connection
Specified Condition
1 (HT) - 2 (+B)
11 to 16 Ω at 20°C (68°F)
1 (HT) - 4 (E)
10 kΩ or higher
If the result is not as specified, replace the sensor.