COOLANT (for Inverter) > REPLACEMENT |
| 1. REMOVE ENGINE UNDER COVER LH |
| 2. REMOVE ENGINE UNDER COVER RH |
| 3. DRAIN COOLANT (for Inverter) |
Remove the transaxle-side reserve tank cap.
![]() |
Remove the plug shown in the illustration and drain the coolant into a container.
Install the plug with a new gasket.
| 4. ADD COOLANT (for Inverter) |
![]() |
Loosen the bleeder plug shown in the illustration and connect a hose.
![]() |
Add coolant until the level of coolant in the hose attached to the bleeder tank reaches the same level as the FULL line of the reserve tank.
Close the bleeder plug.
Turn the power switch ON (IG) and run the water pump for approximately 20 seconds.
Turn the power switch OFF. (*1)
Loosen the bleeder plug and bleed the air from the transaxle. (*2)
Add coolant into the bleeder tank. (*3)
Repeat the steps *1, *2 and *3.
Turn the power switch ON (IG) and run the water pump for approximately 5 minutes after completing air bleeding of the coolant system.
![]() |
Add coolant until the reserve tank is filled up to the FULL mark.
| 5. INSPECT FOR COOLANT LEAK (for Inverter) |
Check for engine coolant leakage .