WIPER SWITCH > INSPECTION |
| 1. INSPECT WINDSHIELD WIPER SWITCH ASSEMBLY |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Position | Specified Condition |
| C14-2 (+B) - C14-3 (+1) | MIST | Below 1 Ω |
| C14-1 (+S) - C14-3 (+1) | OFF | Below 1 Ω |
| C14-1 (+S) - C14-3 (+1) | INT | Below 1 Ω |
| C14-2 (+B) - C14-3 (+1) | LO | Below 1 Ω |
| C14-2 (+B) - C14-4 (+2) | HI | Below 1 Ω |
| Tester Connection | Switch Position | Specified Condition |
| C13-2 (EW) - C13-6 (C1R), C13-2 (EW) - C13-7 (+1R) | OFF | 10 kΩ or higher |
| C13-2 (EW) - C13-6 (C1R) | INT | Below 1 Ω |
| C13-2 (EW) - C13-7 (+1R) | ON | Below 1 Ω |
| Tester Connection | Switch Position | Specified Condition |
| C13-2 (EW) - C13-3 (WF) | OFF | 10 kΩ or higher |
| C13-2 (EW) - C13-3 (WF) | ON | Below 1 Ω |
| Tester Connection | Switch Position | Specified Condition |
| C14-5 (WR) - C13-2 (EW), C13-2 (EW) - C13-7 (+1R) | OFF | 10 kΩ or higher |
| C14-5 (WR) - C13-2 (EW) | ON (WASH1) | Below 1 Ω |
| C14-5 (WR) - C13-2 (EW), C13-2 (EW) - C13-7 (+1R) | ON (WASH2) | Below 1 Ω |
Intermittent Operation Check
Connect the voltmeter positive (+) lead to terminal C14-3 (+1) of the connector and the voltmeter negative (-) lead to terminal C13-2 (EW).
Connect the positive battery (+) lead to terminal C14-2 (+B) of the connector and the negative battery (-) lead to terminals C13-2 (EW) and C14-1 (+S).
Turn the wiper switch to the INT position.
Connect the positive battery (+) lead to terminal C14-1 (+S) of the connector for 5 seconds.
Connect the negative battery (-) lead to terminal C14-1 (+S) of the connector. Operate the intermittent wiper relay and measure the voltage between terminals C14-3 (+1) and C13-2 (EW)

![]() |
Front Washer Operation Check
Turn the wiper switch to the OFF position.
Connect the positive battery (+) lead to terminal C14-2 (+B) of the connector, the negative battery (-) lead to terminals C14- 1 (+S) and the terminal C13-2 (EW).
Connect the voltmeter positive (+) lead to terminal C14-3 (+1) of the connector and the voltmeter negative (-) lead to terminal C13-2 (EW).
Turn the washer switch to the ON and OFF positions, and measure the voltage between terminals C14-3 (+1) and C13-2 (EW).