Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 1NZ-FXE COOLING

1NZ-FXE COOLING > SERVICE DATA



Thermostat
Valve opening temperature
80 to 84°C (176 to 183°F)
Valve lift
at 95°C (203°F)
8.5 mm (0.33 in.) or more
Radiator cap
Standard opening pressure
74 to 103 kPa (0.75 to 1.05 kgf*cm2, 10.7 to 14.9 psi)
Minimum opening pressure
59 kPa (0.6 kgf*cm2, 8.5 psi)
Fan
Standard amperage
at 20°C (68°F)
9.2 to 11.0 A
Integration relay
Resistance
B1 - B4
10 kΩ or higher
Below 1 Ω (when battery voltage is applied to terminals 2 and 3)
No. 1 Cooling fan relay
Resistance
3 - 5
10 kΩ or higher
3 - 5
Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
No. 2 cooling fan relay
Resistance
3 - 4
Below 1 Ω
3 - 5
10 kΩ or higher
3 - 4
10 kΩ or higher (when battery voltage is applied to terminals 1 and 2)
3 - 5
Below 1 Ω (when battery voltage is applied to terminals 1 and 2)