Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 1NZ-FXE STARTING

1NZ-FXE STARTING > SERVICE DATA



Power switch ( Indicator condition)
OFF
OFF
ON (ACC)
Green illumination
ON (IG)
Amber illumination
Hybrid system ON
OFF
Push button start system malfunctioning
Flashes continuously in amber
Power switch
Pushed:
7 (SS2) - 6 (GND)
Below 1 Ω
Pushed:
5 (SS1) - 6 (GND)
Below 1 Ω
Released:
7 (SS2) - 6 (GND)
10 kΩ or higher
Released:
5 (SS1) - 6 (GND)
10 kΩ or higher
Key slot
Key is in key slot:
3(KSW2) - 2(COM)
10 kΩ or higher