Home › HYBRID SYSTEM › P112 HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P0ADC-226    Hybrid Battery Positive Contactor Control Circuit High

DTC    P0ADB-227    Hybrid Battery Positive Contactor Control Circuit Low

for Preparation Click here


DESCRIPTION

Refer to DTC P0AE7 (INF 224) .
The HV control ECU monitors the proper operation of the No. 2 system main relay (CON2) to check for a malfunction.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0ADC
226
Open or +B short in No. 2 system main relay circuit
  1. Wire harness or connector
  2. No. 2 system main relay
  3. HV control ECU
P0ADB
227
GND short in No. 2 system main relay circuit
  1. Wire harness or connector
  2. No. 2 system main relay
  3. HV control ECU

WIRING DIAGRAM

Refer to DTC P0AE7 (INF 224) .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are servicing the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.

HINT:
At least 5 minutes are required to discharge the high-voltage condenser inside the inverter.

1.INSPECT NO. 2 SYSTEM MAIN RELAY
  1. Inspect the No. 2 system main relay .



NG
REPLACE NO. 2 SYSTEM MAIN RELAY
OK


2.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - NO. 2 SYSTEM MAIN RELAY)

CAUTION:
Wear insulated gloves before performing the following operation.

  1. Turn the power switch OFF.

  1. Remove the service plug grip .

    NOTICE:
    Turning the power switch ON (READY) with the service plug grip removed could cause malfunction. Therefore, never turn the power switch ON (READY) in this state.



    A065745E43
  1. Disconnect the H16 HV control ECU connector.



    A093716E04
  1. Disconnect the S22 No. 2 system main relay connector.

  1. Turn the power switch ON (IG).

    HINT:
    DTCs for the interlock switch system are output when turning the power switch ON (IG) with the service plug grip removed.

  1. Measure the voltage between the terminal of the HV control ECU connector and body ground.

    Standard voltage:
    Tester Connection
    Specified Condition
    CON2 (H16-2) - Body ground
    Below 1 V

  1. Turn the power switch OFF.

  1. Measure the resistance between the wire harness side connectors.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    CON2 (H16-2) - CON2 (S22-2)
    Below 1 Ω
    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    CON2 (H16-2) or CON2 (S22-2) - Body ground
    10 kΩ or higher

  1. Reconnect the No. 2 system main relay connector.

  1. Reconnect the HV control ECU connector.

  1. Reinstall the service plug grip .



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE CONTROL ECU