Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › P112 HYBRID BATTERY CONTROL

P112 HYBRID BATTERY CONTROL > SERVICE DATA



Battery plug
Resistance between terminals
10 kΩ or higher
Install the service grip:
Resistance between terminals
Below 1 Ω
No. 1 system main relay
Positive terminal - Negative terminal
10 kΩ or higher
A-2 (CONT2) - B-2 (CONT2)
Below 1 Ω
A-3 (CONT3) - C-2 (CONT3)
Below 1 Ω
B-1 (GND) - GND
Below 1 Ω
C-1 (GND) - GND
Below 1 Ω
Apply battery voltage between the GND terminal and CONT1 terminal of the connector A:
Positive terminal - Negative terminal
Below 1 Ω
A-1 (CONT1) - GND
70 to 160 kΩ
No. 2 system main relay
Positive terminal - Negative terminal
10 kΩ or higher
Apply battery voltage between the connector terminals:
Positive terminal - Negative terminal
Below 1 Ω
Resistance between the connector terminals
20 to 50 kΩ
No. 3 system main relay
Positive terminal - Negative terminal
10 kΩ or higher
Apply battery voltage between the connector terminals:
Positive terminal - Negative terminal
Below 1 Ω
Resistance between the connector terminals
20 to 50 kΩ
System main resistor
Resistance between terminals
18 to 22 Ω
Battery blower relay
3 - 5
10 kΩ or higher
When battery voltage is applied to terminals 1 and 2:
3 - 5
Below 1 Ω
Battery current sensor
Positive probe to terminal 1 (VIB) Negative probe to terminal 2 (GIB)
3.5 to 4.5 kΩ
Positive probe to terminal 2 (GIB) Negative probe to terminal 1 (VIB)
5 to 7 kΩ
Positive probe to terminal 1 (VIB) Negative probe to terminal 3 (IB) A083579E02
3.5 to 4.5 kΩ
Positive probe to terminal 1 (VIB) Negative probe to terminal 3 (IB)
5 to 7 kΩ