Home › BODY ELECTRICAL › LIGHTING › VANITY LIGHT

VANITY LIGHT > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT VISOR ASSEMBLY (VANITY LIGHT SWITCH)
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    Switch is OFF
    10 kΩ or higher
    1 - 2
    Switch is ON
    Below 1 Ω

    If the result is not as specified, replace the visor assembly.



2. INSPECT VANITY LIGHT ASSEMBLY
  1. Connect the battery positive (+) lead from the battery to one of the terminals and battery negative (-) lead to the other terminal, then check that the light comes on.

    OK:
    Light comes on.

    If the result is not as specified, replace the light assembly.