DAYTIME RUNNING LIGHT RELAY > ON-VEHICLE INSPECTION |
| 1. CHECK DAYTIME RUNNING LIGHT RELAY |
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D2-2 (E) - D2-3 (+B) | Always | 10 to 14 V |
| D2-2 (E) - D2-12 (IG) | Engine is running and parking brake is released |
| 2. CHECK DAYTIME RUNNING LIGHT RELAY (Marking: DRL NO. 4) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 3 - 5 | 10 kΩ or higher |
| 3 - 5 | Below 1Ω (when battery voltage is applied to terminal 1 and 2) |