Home › BODY ELECTRICAL › LIGHTING › DAYTIME RUNNING LIGHT RELAY

DAYTIME RUNNING LIGHT RELAY > ON-VEHICLE INSPECTION

for Preparation Click here



1. CHECK DAYTIME RUNNING LIGHT RELAY


I039977E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    D2-2 (E) - D2-3 (+B)
    Always
    10 to 14 V
    D2-2 (E) - D2-12 (IG)
    Engine is running and parking brake is released

    If the result is not as specified, replace the relay.



2. CHECK DAYTIME RUNNING LIGHT RELAY (Marking: DRL NO. 4)


B060778E14
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 5
    Below 1Ω
    (when battery voltage is applied to terminal 1 and 2)

    If the result is not as specified, replace the relay.