Home › HYBRID SYSTEM › P112 HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

HYBRID CONTROL SYSTEM > INFORMATION / FREEZE FRAME DATA

for Preparation Click here



FREEZE FRAME DATA

HINT:
The freeze frame data records the driving condition when the DTC was set. It is used for estimating or simulating the condition of the vehicle when the malfunction occurred. To check the details of the hybrid vehicle control system, check the detailed information for the DTC (Information).

  1. Connect the Techstream to the DLC3.

  2. Turn the power switch ON (IG).

  3. Turn the Techstream ON.

  4. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  5. Select a DTC in order to display its freeze frame data.

  6. Check the freeze frame data of the DTC that has been detected.

  7. Check information of the DTC (see below).

    Freeze frame data: 
    Tester Display
    Measurement Item / Range (Display)
    Suspected Vehicle Status When Malfunction Occurs
    Engine Coolant Temp
    Engine coolant temperature /
    Min.: -40°F (-40°C), Max.: 284°F (140°C)
    Cold or warm engine
    Engine Revolution
    Min.: 0, Max.: 16383.75

    Vehicle Spd
    Vehicle speed /
    Min.: 0 mph (0 km/h), Max.: 158.45 mph (255 km/h)
    Stopped, or driving (low, medium, and high speeds)
    Engine Run Time
    Elapsed time after starting engine /
    Min.: 0 s, Max.: 65,535 s
    Elapsed time from engine start
    +B
    Auxiliary battery voltage /
    Min.: 0 V, Max.: 65.535 V
    Condition of auxiliary battery
    Accel Pedal Pos #1
    No. 1 accelerator pedal position sensor /
    Min.: 0%, Max.: 100%
    Idling, accelerating, or decelerating
    Accel Pedal Pos #2
    No. 2 accelerator pedal position sensor /
    Min.: 0%, Max.: 100%
    Idling, accelerating or decelerating (For comparison with above to detect failure of No. 1 accelerator pedal position sensor)
    Ambient Temperature
    Ambient air temperature /
    Min.: -40°F (-40°C), Max.: 419°F (215°C)
    Ambient air temperature
    Intake Air Temperature
    Intake air temperature /
    Min.: -40°F (-40°C), Max.: 284°F (140°C)
    Ambient air temperature
    DTC Clear Warm Up times
    The number of times engine is warmed up after clearing DTCs /
    Min.: 0, Max.: 255
    Frequency of the malfunction recurrence after clearing DTCs
    DTC Clear Run Distance
    Drive distance after clearing DTCs /
    Min.: 0 km, Max.: 65,535 km
    Frequency of the malfunction recurrence after clearing DTCs
    DTC Clear Min
    Elapsed time after clearing DTCs /
    Min.: 0 min, Max.: 65,535 min
    Frequency of the malfunction recurrence after clearing DTCs
    Type of ECU
    Type of ECU
    -
    Calculate Load
    Min.: 0, Max.: 100

    Throttle POS
    Min.: 0, Max.: 100


INFORMATION

HINT:
Similar to freeze frame data, information records operating condition of the HV system and components at the time of detection of a DTC.

  1. Select one which has an INF code from among INFORMATION 1 to 5.

  2. Check the information of the DTC.

    Information: 
    Tester Display
    Measurement Item / Range (Display)
    Suspected Vehicle Status When Malfunction Occurs
    Information n
    Information code
    Indication of system with malfunction
    Motor (MG2) Revolution
    MG2 revolution /
    Min.: -16,384 rpm, Max.: 16,256 rpm
    MG2 speed (proportionate to vehicle speed)
    1. Forward rotation appears as "+"
    2. Backward rotation appears as "-"
    Moving direction of vehicle
    1. Forward direction appears as "+"
    2. Backward direction appears as "-"
    Motor (MG2) Torq
    MG2 torque /
    Min.: -512 Nm, Max.: 508 Nm
    When MG2 rotation in + direction:
    1. Torque appears as "+" while MG2 discharges
    2. Torque appears as "-" while MG2 charges
    When MG2 rotation in - direction:
    1. Torque appears as "-" while MG2 discharges
    2. Torque appears as "+" while MG2 charges
    Generator (MG1) Rev
    MG1 revolution /
    Min.: -16,384 rpm, Max.: 16,256 rpm
    MG1 speed
    1. Forward rotation appears as "+"
    2. Backward rotation appears as "-"
    Generator (MG1) Torq
    MG1 torque /
    Min.: -512 Nm, Max.: 508 Nm
    When MG1 rotation in + direction:
    1. Torque appears as "+" while MG1 discharges
    2. Torque appears as "-" while MG1 charges
    When MG1 rotation in - direction:
    1. Torque appears as "-" while MG1 discharges
    2. Torque appears as "+" while MG1 charges
    Converter Temperature
    Boost converter temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Boost converter temperature
    Request Power
    Request engine power /
    Min.: 0 W, Max.: 255 kW
    Engine power output requested to ECM
    Engine Spd
    Engine speed /
    Min.: 0 rpm, Max.: 16,320 rpm
    Engine speed
    Master Cylinder Ctrl Trq
    Master cylinder control torque /
    Min.: -512 Nm, Max.: 508 Nm
    Brake force requested by driver
    State of Charge
    Battery state of charge /
    Min.: 0%, Max.: 100%
    State of charge of HV battery
    WOUT Control Power
    Power value discharge control /
    Min.: 0 W, Max.: 81,600 W
    Discharge amount of HV battery
    WIN Control Power
    Power value charge control /
    Min.: -40,800 W, Max.: 0 W
    Charge amount of HV battery
    Power Sesource VB
    HV battery voltage /
    Min.: 0 V, Max.: 510 V
    HV battery voltage
    Power Resource IB
    HV battery current /
    Min.: -256 A, Max.: 254 A
    Charging / discharging state of HV battery
    1. Discharging amperage indicated by a positive value
    2. Charging amperage indicated by a negative value
    VL-Voltage before Boosting
    High voltage before it is boosted /
    Min.: 0 V, Max.: 510 V
    High voltage level before it is boosted
    VH-Voltage after Boosting
    High voltage after it is boosted /
    Min.: 0 V, Max.: 765 V
    High voltage level after it is boosted
    Drive Condition ID
    Drive condition ID
    1. Engine stopped: 0
    2. Engine about to be stopped: 1
    3. Engine about to be started: 2
    4. Engine operated or operating: 3
    5. Generating or loading movement: 4
    6. Revving up with P position: 6
    Engine operating condition
    Shift Sensor Shift Pos
    Shift position (P, R, N, D or B position)
    P: 0, R: 1, N: 2, D: 3, B: 4
    Shift position
    Inverter Temp (MG1)
    MG1 inverter temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MG1 inverter temperature
    Inverter Temp (MG2)
    MG2 inverter temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MG2 inverter temperature
    Motor Temp MG2 (No2)
    Transaxle fluid temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Transaxle fluid temperature
    Motor Temp MG2 (No1)
    MG2 temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MG2 temperature
    Accel Sensor Main
    Accelerator pedal position sensor main /
    Min.: 0%, Max.: 100%
    Idling, accelerating, or decelerating
    Auxiliary Batt Voltage
    Auxiliary battery voltage /
    Min.: 0 V, Max.: 20 V
    State of auxiliary battery
    The Time of Ignition ON
    The time after power switch ON (IG) /
    Min.: 0 min, Max.: 255 min
    Time elapsed with power switch ON (IG)
    Vehicle Speed (Max)
    Maximum vehicle speed /
    Min.: -159.07 mph (-256 km/h), Max.: 157.83 mph (254 km/h)
    Maximum vehicle speed
    A/C Consumption Pwr
    A/C consumption power /
    Min.: 0 kW, Max.: 5 kW
    A/C load
    Engine Fuel Cut
    Engine fuel cut request /
    NO or YES
    Presence of fuel cut request
    Stop Swich
    Stop light switch ON condition /
    NO or YES
    Brake pedal depressed or released
    Cruise Control
    Cruise control active condition /
    NO or YES
    Operation under cruise control ON or OFF
    Exclusive Information 1 to 7
    Exclusive information (in form of numerical data)
    Exclusive Information linked to Information
    Occurrence Order
    Occurrence sequence of information / Min.: 0, Max.: 255
    Occurrence sequence of information
    Inv-T (MG1) after IG-ON
    MG1 inverter temperature after power switch ON (IG) /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MG1 inverter temperature soon after power switch ON (IG)
    Inv-T (MG2) after IG-ON
    MG2 inverter temperature after power switch ON (IG) /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MG2 inverter temperature soon after power switch ON (IG)
    Mtr-T (MG2) after IG-ON
    MG2 temperature after power switch ON (IG) /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    MG2 temperature soon after power switch ON (IG)
    Conv-Tmp after IG-ON
    Boost converter temperature after power switch ON (IG) /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Boost converter temperature soon after power switch ON (IG)
    SOC after IG-ON
    Battery state of charge after power switch ON (IG) /
    Min.: 0%, Max.: 100%
    Battery state of charge soon after power switch ON (IG)
    Inv-Temp (MG1) Max
    MG1 inverter maximum temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Overheating state of MG1 inverter
    Inv-Temp (MG2) Max
    MG2 inverter maximum temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Overheating state of MG2 inverter
    Mtr-Temp (MG2) Max
    MG2 maximum temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Overheating state of MG2
    Converter Temp Max
    Boost converter maximum temperature /
    Min.: -58°F (-50°C), Max.: 401°F (205°C)
    Overheating state of boost converter
    Status of Charge Max
    Maximum status of charge /
    Min.: 0%, Max.: 100%
    Over-charging of HV battery
    Status of Charge Min
    Minimum status of charge /
    Min.: 0%, Max.: 100%
    Over-discharging of HV battery
    Engine Stop Request
    Engine stop request /
    NO or YES
    Presence of engine stop request
    Engine Idling Request
    Engine idling request /
    NO or YES
    Presence of idle stop request
    Main Batt Charging Rqst
    HV battery charging request /
    NO or YES
    Presence of HV battery charging request
    Engine Warming Up Rqst
    Engine warming up request /
    NO or YES
    Presence of engine warm-up request