HYBRID CONTROL SYSTEM > OPERATION HISTORY DATA |
| OPERATION HISTORY DATA |
Connect the Techstream to the DLC3.
Turn the power switch ON (IG).
Enter the following menus: Powertrain / Engine Control / Data List.
Select the menu to view the number of special operations or controls that have been effected.
| Tester Display | Count Condition |
| Shift gear before READY | Shift lever moved with READY light blinking |
| N range control in half shift | N position control effected due to frequent shifting operation |
| Step Accelerator in N range | Accelerator pedal depressed in N position |
| Auxiliary Battery Low | Auxiliary battery voltage below 9.5 V |
| HV ECU Intermittent problems | Instantaneous open at IGSW terminal of HV control ECU |
| MG2 (motor ) temperature high | Motor temperature rose above 345°F (174°C) |
| MG1 (generator) temperature high | Transaxle fluid temperature rose above 324°F (162°C) |
| MG2 (motor) Inverter temperature high | Motor inverter temperature rose above 232°F (111°C) |
| MG1 (generator) Inverter temperature high | Generator inverter temperature rose above 232°F (111°C) |
| Main Battery low voltage | Battery state of charge dropped below 30% |
| Resister over heat | Limit resistor forecast temperature rose above 248°F (120°C) |
| Coolant heating | Inverter coolant forecast temperature rose above 149°F (65°C) |
| Converter heating | Boost converter temperature rose above 232°F (111°C) |
| Shift P in running | Shifted to P while driving |
| Shift backward direction | Shifted to R while moving forward or to D or B while moving in reverse |
| Prevention control of staying | Engine speed stays in resonance frequency band |
| Accelerator and brake depressing | Both accelerator and brake pedals depressed |
| Shift without depressing brake | Shift lever moved from P without depressing brake pedal |
| Shift R or D during Ready OFF | Shift lever moved R or D while READY is off |
| HV CPU reset by power supply Integrated Circuit | HV CPU reset by power supply IC |
| HV CPU reset by Motor Main CPU | HV CPU reset by MG ECU |