Home › HYBRID SYSTEM › P112 HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

HYBRID CONTROL SYSTEM > OPERATION HISTORY DATA

for Preparation Click here



OPERATION HISTORY DATA

HINT:
The operation history data records the special operations performed by the driver and the number of abnormal conditions that have been input into the HV control ECU.

  1. Connect the Techstream to the DLC3.

  2. Turn the power switch ON (IG).

  3. Enter the following menus: Powertrain / Engine Control / Data List.

  4. Select the menu to view the number of special operations or controls that have been effected.

HINT:
  1. LATEST OPER: Among the past occurrences, the number of special operations or controls that have been effected during the most recent 1 trip detection.
  2. LATEST TRIP: The number of trips after the occurrence of LATEST OPER.
  3. BEF LATEST OPER: The number of occurrences 1 previously from the LATEST OPER.
  4. BEF LATEST TRIP: The number of trips after the occurrence of BEF LATEST OPER.


Operation history data: 
Tester Display
Count Condition
Shift gear before READY
Shift lever moved with READY light blinking
N range control in half shift
N position control effected due to frequent shifting operation
Step Accelerator in N range
Accelerator pedal depressed in N position
Auxiliary Battery Low
Auxiliary battery voltage below 9.5 V
HV ECU Intermittent problems
Instantaneous open at IGSW terminal of HV control ECU
MG2 (motor ) temperature high
Motor temperature rose above 345°F (174°C)
MG1 (generator) temperature high
Transaxle fluid temperature rose above 324°F (162°C)
MG2 (motor) Inverter temperature high
Motor inverter temperature rose above 232°F (111°C)
MG1 (generator) Inverter temperature high
Generator inverter temperature rose above 232°F (111°C)
Main Battery low voltage
Battery state of charge dropped below 30%
Resister over heat
Limit resistor forecast temperature rose above 248°F (120°C)
Coolant heating
Inverter coolant forecast temperature rose above 149°F (65°C)
Converter heating
Boost converter temperature rose above 232°F (111°C)
Shift P in running
Shifted to P while driving
Shift backward direction
Shifted to R while moving forward or to D or B while moving in reverse
Prevention control of staying
Engine speed stays in resonance frequency band
Accelerator and brake depressing
Both accelerator and brake pedals depressed
Shift without depressing brake
Shift lever moved from P without depressing brake pedal
Shift R or D during Ready OFF
Shift lever moved R or D while READY is off
HV CPU reset by power supply Integrated Circuit
HV CPU reset by power supply IC
HV CPU reset by Motor Main CPU
HV CPU reset by MG ECU