Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2012.03–2016.05
NM2070E _51 Engine / Hybrid System _061859 HYBRID / BATTERY CONTROL _0301394 HYBRID CONTROL SYSTEM UN GENERAL/CONTROL/DETAILS F

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  GENERAL/CONTROL/DETAILS  DETAILS  


FUNCTION OF MAIN COMPONENTS


a.

The main components of the hybrid system have the following functions:

Component Function
Power Management Control ECU

Performs comprehensive control of the hybrid system.

-

Information from various sensors as well as from ECUs (ECM, MG ECU, battery smart unit and skid control ECU) is received, and based on this the required torque and output power are calculated. The power management control ECU transmits the calculated result to the ECM, MG ECU and skid control ECU.

-

Monitors the SOC of the HV battery.

-

Controls the DC-DC converter.

-

Controls the inverter water pump assembly.

-

Controls the battery cooling blower assembly.



Hybrid Vehicle Transaxle Assembly Motor Generator No. 1 (MG1) MG1, which is driven by the engine, generates high-voltage electricity in order to operate MG2 and charge the HV battery. Also, it functions as a starter to start the engine.
Motor Generator No. 2 (MG2)
·

MG2, which is driven by electrical power from MG1 and the HV battery, generates motive force for the drive wheels.

·

During braking, or when the accelerator pedal is not depressed, it generates high-voltage electricity to recharge the HV battery.


Generator Resolver (For MG1) Detects the rotor position, rotational speed and direction of MG1.
Motor Resolver (For MG2) Detects the rotor position, rotational speed and direction of MG2.
Generator Temperature Sensor (For MG1) Detects the temperature of MG1.
Motor Temperature Sensor (For MG2) Detects the temperature of MG2.
Compound Gear Unit Power Split Planetary Gear Unit Distributes the engine motive force as appropriate to directly drive the vehicle as well as MG1.
Motor Speed Reduction Planetary Gear Unit Reduces the rotational speed of MG2 in accordance with the characteristics of the planetary gear, in order to increase torque.
Inverter with Converter Assembly Inverter Converts the direct current from the boost converter into alternating current for MG1 and MG2, and vice versa (from AC to DC).
Boost Converter Boosts the HV battery nominal voltage of DC 201.6 V up to a maximum voltage of DC 650 V and vice versa (steps down DC 650 V to DC 201.6 V).
DC-DC Converter Steps down the HV battery nominal voltage of DC 201.6 V to approximately DC 14 V in order to supply electricity to the electrical components, as well as to recharge the auxiliary battery.
MG ECU Controls the inverter and boost converter in accordance with the signals received from the power management control ECU, thus operating MG1 and MG2 as either a generator or motor.
Atmospheric Pressure Sensor Detects the atmospheric pressure.
Temperature Sensor for Inverter with Converter Assembly Detects temperatures in the parts of the inverter with converter assembly as well as the HV coolant temperature.
Inverter Current Sensor Detects the current of MG1 and MG2.
HV Battery Assembly HV Battery Stack
·

Supplies electrical power to MG1 and MG2 in accordance with the driving conditions of the vehicle.

·

Recharged by MG1 and MG2 in accordance with the SOC and the driving conditions of the vehicle.


HV Battery Temperature Sensor Detects temperatures in the parts of the HV battery.
HV Battery Intake Air Temperature Sensor Detects the Intake air temperature from the battery cooling blower assembly.
Hybrid Battery Junction Block Assembly System Main Relays Connects and disconnects the high-voltage circuit between the HV battery and the inverter with converter assembly through the use of signals from the power management control ECU.
Battery Current Sensor Detects the input and output current of the HV battery.
Battery Smart Unit
·

Monitors the conditions of the HV battery such as voltage, current and temperature, and transmits this information to the power management control ECU.

·

Monitors the high-voltage system for breakdown of the electrical insulation.


Service Plug Grip Shuts off the high-voltage circuit of the HV battery when the service plug grip is removed for vehicle inspection or maintenance.
Interlock Switch (for Service Plug Grip/for Inverter Terminal Cover/for Power Cable Connector) Verifies that the service plug grip, inverter terminal cover and inverter power cable connector are installed.
Power Cable (Frame Wire) Connects the HV battery, inverter with converter assembly, hybrid vehicle transaxle assembly and compressor with motor assembly.
Inverter Water Pump Assembly Operates under the control of the power management control ECU in order to cool the inverter with converter assembly, MG1 and MG2.
Battery Cooling Blower Assembly Operates under the control of the power management control ECU in order to cool the HV battery.
Auxiliary Battery Supplies electricity to the electrical components.
Auxiliary Battery Temperature Sensor (Thermistor Assembly) Detects the temperature of the auxiliary battery.
Power Switch Starts and stops the hybrid system.
Accelerator Pedal Sensor Assembly Converts the accelerator pedal position into an electrical signal and sends it to the power management control ECU.
Shift Lock Control Unit Assembly Shift Lever Position Sensor (Select Sensor) Converts the shift position (lateral movement) into electrical signals and sends them to the power management control ECU.
Shift Lever Position Sensor (Shift Sensor) Converts the shift position (longitudinal movement) into electrical signals and sends them to the power management control ECU.
P Position Switch (Transmission Shift Main Switch) Outputs the P position switch signal to the power management control ECU (HV CPU) when operated by the driver.
Stop Light Switch Detects the depression of the brake pedal.
EV Drive Mode Switch Sends the EV drive mode switch signal to the power management control ECU when operated by the driver.
POWER Mode Switch Sends the POWER mode switch signal to the power management control ECU via the ECM when operated by the driver.
ECO Mode Switch Sends the ECO mode switch signal to the power management control ECU via the air conditioning amplifier assembly when operated by the driver.
ECM
·

Performs control of the engine in accordance with the target engine speed and required engine motive force received from the power management control ECU.

·

Transmits various engine operating condition signals to the power management control ECU.


Skid Control ECU (Brake Booster with Master Cylinder Assembly)
·

During braking, it calculates the required regenerative braking force and transmits it to the power management control ECU.

·

Transmits the request to the power management control ECU to limit motive force while the TRC or VSC is operating.


Air Conditioning Amplifier Assembly Transmits various A/C state signals to the power management control ECU.
Airbag ECU Assembly During a collision, it transmits the airbag deployment signal to the power management control ECU.
Combination Meter Sub-assembly Hybrid System Indicator Displays the system power output and regenerative charging of the hybrid system.
READY Indicator Light Informs the driver that the vehicle is ready to drive.
Hybrid System Warning Light In this context, the primary function of this warning light is to inform the driver of a malfunction in the hybrid system. The light illuminates simultaneously with the sounding of a warning buzzer.
Hybrid System Overheat Warning Light Warns the driver when the hybrid system is overheating.
ECO Driving Indicator Light Turns on during Eco-friendly acceleration (Eco driving).
Hybrid Battery Indicator Light Informs the driver that the lithium-ion battery will soon need to be inspected or replaced.
EV Drive Indicator Light Turns on during EV driving.
Shift Position Indicator Shows the shift state selected by the driver.
EV Drive Mode Indicator Light Informs the driver that EV drive mode is selected.
PWR Mode Indicator Light Informs the driver that PWR mode is selected.
Eco Mode Indicator Light Informs the driver that ECO mode is selected.
Discharge Warning Light Turns on when there is a malfunction in the auxiliary battery charging system.
Malfunction Indicator Lamp (MIL) Turns on when there is a malfunction in the hybrid control system and engine control system.
Radio and Display Receiver Assembly*1 Displays the energy monitor.
Navigation Receiver Assembly*2

*1: Models with touch screen system or display audio system

*2: Models with HDD navigation system



OPERATING CONDITION


a.

Hybrid System Activation (READY-on State)

i.

The hybrid system can be activated by pressing the power switch while the brake pedal is being depressed. At this time, the READY indicator light flashes until the system check is completed. When the READY indicator light turns on, the hybrid system has started and the vehicle is ready to drive.


ii.

Even if the driver turns the power switch on (READY), sometimes the power management control ECU will not start the engine. The engine will only start if conditions such as engine coolant temperature, SOC, HV battery temperature and electrical load require an engine start.


iii.

After driving, when the driver stops the vehicle and turns the P position switch on, the power management control ECU allows the engine to continue running. The engine will stop after the SOC, HV battery temperature and electrical load reach a specified level.

NOTICE:

When the hybrid system is unavoidably required to be stopped while driving, the system can be forced to stop by pressing and holding the power switch for approximately 2 seconds or more or pushing the power switch 3 times or more in a row. At this time, the power source will change to on (ACC).




b.

EV Drive Mode

i.

When all required conditions, some of which are listed below, are satisfied, EV drive mode can be used.

Operating Condition
·

The hybrid system temperature is not high. (The hybrid system temperature will be high when the outside air temperature is high or after the vehicle has traveled up a hill or at high speeds.)

·

The hybrid system temperature is not low. (The hybrid system temperature will be low after the vehicle has been left for a long time when the outside air temperature is low.)

·

The engine coolant temperature is approximately 0°C (32°F) or more.

·

The SOC is approximately 50% or more.

·

The vehicle speed is approximately 30 km/h (19 mph) or less. (Cold engine conditions)

·

The vehicle speed is approximately 45km/h (28 mph) or less. (Warm engine conditions)

·

The accelerator pedal depression amount is a certain level or below.

·

The defroster is off.

·

The cruise control system is not operating.



HINT:

The available cruising range during EV drive mode varies according to the SOC of the HV battery and the driving conditions such as road surfaces and hills. However, it is usually between several hundred meters (several hundred yards) and approximately 2 km (1.2 miles).




c.

State Of Charge (SOC)

i.

The power management control ECU estimates the SOC of the HV battery from the accumulated amperage that is constantly and repeatedly being charged and discharged. In order to maintain the SOC at the appropriate level all the time, the power management control ECU controls the hybrid system optimally.

W101107E21
1.906,1.958 1.906,0.948 1.906,0.948 1.583,0.948 true 2.938,1.781 2.938,0.917 2.938,0.917 3.271,0.917 true 0.323,0.833 1.583,1.063 1.26,0.229 10 false SOC Control Target 3.323,0.792 5.104,1 1.781,0.208 10 false Example of change in SOC 0.417,1.885 0.792,2.104 0.375,0.219 10 false SOC 2.271,2.76 2.75,3.073 0.479,0.313 10 false Time 5.323,1.49 6.927,1.677 1.604,0.188 10 false Upper SOC Control Limit 5.198,1.865 6.281,2.083 1.083,0.219 10 false Control Region 5.323,2.208 6.906,2.427 1.583,0.219 10 false Lower SOC Control Limit



d.

Detection of Insulation Resistance Decrease

i.

The leak detection circuit is built in the battery smart unit. The leak detection circuit constantly monitors that the insulation resistance between high-voltage circuits and body ground is maintained.


ii.

The power management control ECU determines decreases in the insulation resistance based on the information from the battery smart unit.


iii.

The leak detection circuit has an AC source and causes a small amount of AC to flow to the high-voltage circuit (positive and negative).


iv.

The more insulation resistance decreases, the more voltage drops at the detection resistor and the lower the waves of AC. The insulation resistance value is detected based on the amplitude of AC waves.

W101611E37
0.344,0.208 2.479,0.385 2.135,0.177 10 false Power Management Control ECU 3.729,0.208 5.885,0.406 2.156,0.198 10 false Combination Meter Sub-assembly 3.802,0.542 5.865,0.76 2.063,0.219 10 false - Hybrid System Warning Light 2.646,0.688 3.552,0.927 0.906,0.24 10 false CAN (V Bus) 3.885,1.938 4.688,2.146 0.802,0.208 10 false HV Battery 0.833,2.781 1.646,3 0.813,0.219 10 false AC Source 5.115,2.854 6.542,3.083 1.427,0.229 10 false Insulation Resistance 3.281,1.26 4.542,1.458 1.26,0.198 10 false High-voltage Circuit 0.833,1.938 1.958,2.135 1.125,0.198 10 false Voltage Detection 0.833,3.156 2.51,3.375 1.677,0.219 10 false Battery Smart Unit 0.833,2.427 2.104,2.635 1.271,0.208 10 false Detection Resistor 5.313,1.635 6.469,1.823 1.156,0.188 10 false High-voltage Load 1.458,1.24 3.042,1.49 1.583,0.25 10 false Serial Communication



e.

Cut-off of High-Voltage Circuits during Collision

i.

If the vehicle is involved in a collision as described below, the power management control ECU will shut down the power supply by turning the system main relays off for safety.


ii.

The power management control ECU receives the airbag deployment signal from the airbag ECU assembly during a frontal collision, side collision or side rear collision.

W101612E22
5.448,1.125 6.729,1.531 1.281,0.406 10 false Power Management Control ECU 3.146,1.135 3.917,1.531 0.771,0.396 10 false Airbag ECU Assembly 4.115,1.51 4.99,1.771 0.875,0.26 10 false CAN (V Bus) 0.448,1.813 1.396,2.031 0.948,0.219 10 false Side Collision 0.271,2.146 1.594,2.365 1.323,0.219 10 false Side Rear Collision 0.365,0.771 1.479,0.99 1.115,0.219 10 false Frontal Collision 5.552,2.323 6.51,2.531 0.958,0.208 10 false SMR Shut Off 2.104,1.719 2.625,1.938 0.521,0.219 10 false Impact




SYSTEM CONTROL


a.

Control List

i.

The hybrid system consists of the controls listed below.

Control Outline
Hybrid Vehicle Control
·

The power management control ECU calculates the target motive force based on the shift lever position sensor, the degree to which the accelerator pedal is depressed, and the vehicle speed. It performs control in order to create the target motive force by optimally combining MG1, MG2 and the engine.

·

The power management control ECU calculates the engine motive force based on the target motive force, which has been calculated based on the requirements of the driver and the driving conditions of the vehicle. In order to create this motive force, the power management control ECU transmits the signals to the ECM.

·

The power management control ECU monitors the SOC of the HV battery and the temperature of the HV battery, MG1 and MG2, in order to optimally control these items.


SOC Control
·

The power management control ECU calculates the SOC by estimating the charging and discharging amperage of the HV battery.

·

The power management control ECU constantly performs charge/discharge control based on the calculated SOC in order to maintain the SOC within its target range.


Engine Control The ECM receives the target engine speed and required engine motive force, which were sent from the power management control ECU, and controls the ETCS-i, fuel injection volume, ignition timing, VVT-i and EGR.
MG1 and MG2 Main Control
·

MG1, which is driven by the engine, generates high-voltage electricity in order to operate MG2 and charge the HV battery. Also, it functions as a starter to start the engine.

·

MG2, which is driven by electrical power from MG1 and the HV battery, generates motive force for the drive wheels.

·

MG2 generates high-voltage electricity to charge the HV battery during braking (regenerative braking cooperative control), or when the accelerator pedal is not being depressed (energy regeneration).

·

MG1 and MG2 are basically shut down when neutral (N) is selected. In order to stop providing motive force, it is necessary to stop driving MG1 and MG2, because MG1 and MG2 are mechanically joined to the drive wheels.


Inverter Control
·

The inverter converts the direct current from the HV battery into alternating current for MG1 and MG2, or vice versa, in accordance with the signals provided by the power management control ECU via the MG ECU. In addition, the inverter is used to transfer power from MG1 to MG2.

·

The power management control ECU shuts down the inverter if it receives an overheating, overcurrent or voltage fault signal from the inverter via the MG ECU.


Boost Converter Control
·

The boost converter boosts the HV battery nominal voltage of DC 201.6 V up to a maximum voltage of DC 650 V, in accordance with the signals provided by the power management control ECU via the MG ECU.

·

The inverter converts the alternating current generated by MG1 or MG2 into the direct current. The boost converter steps down the generated voltage of DC 650 V (maximum voltage) to approximately DC 201.6 V, in accordance with the signals provided by the power management control ECU via the MG ECU.


DC-DC Converter Control The DC-DC converter steps down the HV battery nominal voltage of DC 201.6 V to approximately DC 14 V in order to supply electricity to the electrical components, as well as to recharge the auxiliary battery.
System Main Relay Control To ensure that it is possible to connect and disconnect the high-voltage circuits reliably, the power management control ECU controls the 3 system main relays to connect and disconnect the high-voltage circuits from the HV battery. The power management control ECU also uses the timing of the operation of the 3 system main relays to monitor the operation of the relay contacts.
Cooling System Control for Inverter with Converter Assembly In order to cool the inverter with converter assembly, MG1 and MG2, the power management control ECU regulates the inverter water pump assembly according to the signals from the temperature sensor for inverter with converter assembly, temperature sensor for MG1 and temperature sensor for MG2.
Cooling System Control for HV Battery In order to maintain the HV battery temperature at the optimum level, the power management control ECU regulates the battery cooling blower assembly according to the signals from the HV battery temperature sensors and HV battery intake air temperature sensor.
Regenerative Braking Cooperative Control During braking, the skid control ECU calculates the required regenerative braking force and transmits it to the power management control ECU. Upon receiving this signal, the power management control ECU transmits the actual regenerative braking control value to the skid control ECU. Based on this result, the skid control ECU calculates and executes the required hydraulic braking force.
TRC/VSC Cooperative Control The skid control ECU transmits the request to the power management control ECU to limit motive force while the TRC or VSC is operating. The power management control ECU controls the engine and MG2 in accordance with the present driving conditions in order to suppress the motive force. For details, refer to Brake Control System.
During Collision Control During a collision, if the power management control ECU receives the airbag deployment signal from the airbag ECU assembly, it turns the system main relays off in order to shut off the high-voltage from the HV battery.
Cruise Control System Operation Control When the power management control ECU receives the cruise control switch signal, it controls the motive forces of the engine and MG2 to be an optimum combination in order to obtain the target vehicle speed by the driver's demand. For details, refer to Cruise Control System.
Dynamic Radar Cruise Control System Operation Control* Upon receiving the motive force request signal from the driving support ECU, the power management control ECU controls the motive forces of the engine and MG2 to be an optimum combination in order to obtain the target vehicle speed. For details, refer to Dynamic Radar Cruise Control System.
Shift Control The power management control ECU detects the driver's desired shift state (P, R, N, D or B) in accordance with the signals provided by the shift lever position sensor and P position switch. Based on these inputs and vehicle operating conditions, the power management control ECU controls MG1, MG2 and the engine to match the selected shift state.
EV Drive Mode Control When the EV drive mode switch is operated by the driver, the power management control ECU uses only MG2 to drive the vehicle if the operating conditions are satisfied.
PWR Mode Control When the POWER mode switch is operated by the driver, the power management control ECU moderates the response of the accelerator pedal operation to optimize acceleration.
ECO Mode Control When the ECO mode switch is operated by the driver, the power management control ECU moderates the response of the accelerator pedal operation to support Eco driving.
Brake Override Control Restricts the driving torque when brake pedal is depressed while the accelerator pedal is depressed. (For the Activation Conditions and Inspection Method, refer to the Repair Manual).
Engine Immobiliser Prohibits fuel delivery, ignition and starting the hybrid control system if an attempt is made to start the hybrid control system with an invalid key.

*: Models with dynamic radar cruise control system



b.

Hybrid Vehicle Control

i.

The power management control ECU detects the degree to which the accelerator pedal is depressed using the signals from the accelerator pedal sensor assembly and detects the shift position signals from the shift lever position sensor. The power management control ECU receives the speed signals from the MG1 and MG2 resolvers via the MG ECU. The power management control ECU determines the driving conditions of the vehicle in accordance with this information, and optimally controls the motive forces of MG1, MG2 and the engine. Furthermore, the power management control ECU optimally controls the output and torque of MG1, MG2 and the engine in order to deliver lower fuel consumption and cleaner exhaust emissions.


ii.

The power management control ECU calculates the engine motive force based on the calculated target motive force, and by taking the SOC and the temperature of the HV battery into consideration. The value obtained by subtracting the engine motive force from the target motive force is the MG2 motive force.


iii.

The ECM performs control of the engine in accordance with the target engine speed and required engine motive force received from the power management control ECU. Furthermore, the power management control ECU appropriately operates MG1 and MG2 in order to provide the required MG1 generation force and the required MG2 motive force.

W108478E04
0.25,3.708 1.865,4.083 1.615,0.375 10 false Accelerator Pedal Sensor Assembly 0.25,4.719 2,4.938 1.75,0.219 10 false Shift Lever Position Sensor 0.688,6.667 1.365,6.854 0.677,0.188 10 false MG ECU 0.438,8.146 1.854,8.365 1.417,0.219 10 false Resolver (MG1, MG2) 0.26,7.042 1.792,7.271 1.531,0.229 10 false - Resolver Speed Signal 5.177,2.75 5.667,3 0.49,0.25 10 false ECM 5.167,3.167 6.281,3.375 1.115,0.208 10 false - Engine Control 5.177,5.063 5.875,5.26 0.698,0.198 10 false MG ECU 5.156,5.49 6.99,5.708 1.833,0.219 10 false - MG1 and MG2 Main Control 5.177,5.906 6.271,6.125 1.094,0.219 10 false - Inverter Control 5.167,6.292 6.792,6.51 1.625,0.219 10 false - Boost Converter Control 0.385,2.083 1.698,2.292 1.313,0.208 10 false Battery Smart Unit 0.365,2.458 1.771,2.979 1.406,0.521 10 false - HV Battery Condition (Voltage, Current, Temperature) 2.625,5.188 3.313,6.073 0.688,0.885 10 false Target Motive Force Calculation 2.625,2.469 3.344,2.896 0.719,0.427 10 false SOC Calculation 0.104,0.125 2.844,0.417 2.74,0.292 12 false Flow of Motive Force Calculation: 1.438,0.646 5.646,0.865 4.208,0.219 10 false (Target Motive Force) - (Engine Motive Force) = (MG2 Motive Force) 2.521,1.469 4.719,1.698 2.198,0.229 10 false Power Management Control ECU 3.813,4.354 4.531,5.094 0.719,0.74 10 false MG1 Generation Force Calculation 3.823,2.448 4.521,3.25 0.698,0.802 10 false Engine Motive Force Calculation 3.813,6.042 4.521,6.833 0.708,0.792 10 false MG2 Motive Force Calculation 0.625,5.854 1.594,6.073 0.969,0.219 10 false Select Sensor 0.698,5.26 1.573,5.458 0.875,0.198 10 false Shift Sensor



c.

SOC Control

i.

The power management control ECU calculates the SOC of the HV battery based on the charge/discharge amperage detected by the battery current sensor. The power management control ECU constantly performs charge/discharge control based on the calculated SOC in order to maintain the SOC within its target range.


ii.

While the vehicle is in motion, the HV battery undergoes repetitive charge/discharge cycles, as it becomes discharged by MG2 during acceleration and charged by regenerative braking during deceleration.


iii.

When the SOC is below the lower level, the power management control ECU increases the power output of the engine to operate MG1, which charges the HV battery.


iv.

The battery smart unit converts the HV battery related signals (voltage, current and temperature) into digital signals, and transmits them to the power management control ECU via serial communication. These signals are needed to determine the SOC that is calculated by the power management control ECU.

W104329E26
0.375,0.333 1.854,0.563 1.479,0.229 10 false Battery Current Sensor 2.688,1.479 3.917,1.688 1.229,0.208 10 false Battery Smart Unit 4.135,1.958 5.635,2.219 1.5,0.26 10 false Serial Communication 0.427,1.313 1.24,1.531 0.813,0.219 10 false HV Battery 0.427,1.656 1.792,1.875 1.365,0.219 10 false - HV Battery Voltage 0.51,2.271 1.75,2.802 1.24,0.531 10 false HV Battery Temperature Sensor 5.615,1.188 6.885,1.552 1.271,0.365 10 false Power Management Control ECU



d.

Engine Control

i.

The ECM receives the target engine speed and required engine motive force, which were sent from the power management control ECU, and controls the ETCS-i, fuel injection volume, ignition timing, VVT-i and EGR.


ii.

The ECM transmits the operating conditions of the engine to the power management control ECU.


iii.

Upon receiving the engine stop signal from the power management control ECU in accordance with the basic hybrid vehicle control, the ECM will stop the engine.

W101256E22
5.771,0.594 6.802,0.802 1.031,0.208 10 false ETCS-i Control 5.563,1.219 6.896,1.583 1.333,0.365 10 false Fuel Injection Volume Control 5.781,2.198 6.719,2.583 0.938,0.385 10 false Ignition Timing Control 4.146,1.958 4.625,2.208 0.479,0.25 10 false ECM 0.688,4.01 2.021,4.229 1.333,0.219 10 false : CAN (Sub Bus 12) 1.906,1.542 3.615,1.76 1.708,0.219 10 false Engine Control Requests 1.802,2.313 3.635,2.531 1.833,0.219 10 false Engine Operating Conditions 0.292,1.406 1.552,1.833 1.26,0.427 10 false Power Management Control ECU 5.844,3.177 6.75,3.385 0.906,0.208 10 false VVT-i Control 5.854,3.76 6.74,3.969 0.885,0.208 10 false EGR Control



e.

MG1 and MG2 Main Control

i.

MG1, which is driven by the engine, generates high-voltage electricity in order to operate MG2 and charge the HV battery. Also, it functions as a starter to start the engine.


ii.

MG2, which is driven by electrical power from MG1 and the HV battery, generates motive force for the drive wheels.


iii.

MG2 generates high-voltage electricity to charge the HV battery during braking (regenerative braking cooperative control), or when the accelerator pedal is not being depressed (energy regeneration).


iv.

MG1 and MG2 are basically shut down when neutral (N) is selected. In order to stop providing motive force, it is necessary to stop driving MG1 and MG2, because MG1 and MG2 are mechanically joined to the drive wheels.


v.

The MG ECU controls the Insulated Gate Bipolar Transistors (IGBTs) in the Intelligent Power Module (IPM) based on the signals received from the power management control ECU. The IGBTs are used for switching for the U, V, and W phases of each motor generator. There are 6 IGBTs that switch on and off to control each individual motor generator in accordance with operation as either a motor or as a generator.


vi.

The illustration below describes the basic control used when the motor generator functions as a motor. The IGBTs in the IPM switch on and off to supply three-phase alternating current to the motor generator. In order to create the motive force required of the motor generator as calculated by the power management control ECU, the MG ECU switches the IGBTs on and off in order to control the speed of the motor generator.

W101616E12
1.354,6 1.354,5.344 1.354,5.344 1.448,5.344 true 0.771,7.344 0.771,6.74 true 0.771,3.458 0.771,2.792 0.771,2.792 0.865,2.792 true 1.948,4.823 1.948,4.219 true 1.938,0.896 1.938,0.229 1.938,0.229 2.031,0.229 true 1.365,2.188 1.365,1.646 true 5.063,5.885 5.271,6.083 0.208,0.198 10 false U 4.635,5.625 4.938,5.844 0.302,0.219 10 false (+) 4.646,6.958 4.948,7.177 0.302,0.219 10 false (-) 5.542,5.885 5.75,6.083 0.208,0.198 10 false V 6.021,5.885 6.229,6.083 0.208,0.198 10 false W 3.49,5.844 3.698,6.042 0.208,0.198 10 false U 3,6.646 3.208,6.844 0.208,0.198 10 false V 3.781,6.635 3.99,6.833 0.208,0.198 10 false W 3.052,6.885 4.177,7.104 1.125,0.219 10 false Motor Generator 2.25,7.167 2.615,7.385 0.365,0.219 10 false IPM 1.531,5.24 2.313,5.427 0.781,0.188 10 false IGBT: ON 0.458,7.365 1.24,7.583 0.781,0.219 10 false IGBT: ON 5.052,3.344 5.26,3.542 0.208,0.198 10 false U 4.635,3.115 4.938,3.333 0.302,0.219 10 false (+) 4.646,4.406 4.948,4.625 0.302,0.219 10 false (-) 5.552,3.333 5.76,3.531 0.208,0.198 10 false V 6.031,3.333 6.24,3.531 0.208,0.198 10 false W 3.479,3.313 3.688,3.51 0.208,0.198 10 false U 3,4.063 3.208,4.26 0.208,0.198 10 false V 3.792,4.073 4,4.271 0.208,0.198 10 false W 3.063,4.406 4.125,4.625 1.063,0.219 10 false Motor Generator 2.25,4.615 2.615,4.833 0.365,0.219 10 false IPM 0.927,2.688 1.667,2.865 0.74,0.177 10 false IGBT: ON 1.625,4.833 2.313,5.021 0.688,0.188 10 false IGBT: ON 5.063,0.792 5.271,0.99 0.208,0.198 10 false U 4.635,0.563 4.938,0.781 0.302,0.219 10 false (+) 4.646,1.865 4.948,2.083 0.302,0.219 10 false (-) 5.573,0.792 5.781,0.99 0.208,0.198 10 false V 6.031,0.792 6.24,0.99 0.208,0.198 10 false W 3.49,0.771 3.698,0.969 0.208,0.198 10 false U 3,1.563 3.208,1.76 0.208,0.198 10 false V 3.781,1.552 3.99,1.75 0.208,0.198 10 false W 3.063,1.844 4.146,2.073 1.083,0.229 10 false Motor Generator 2.25,2.083 2.615,2.302 0.365,0.219 10 false IPM 2.115,0.125 2.854,0.313 0.74,0.188 10 false IGBT: ON 1.063,2.219 1.844,2.438 0.781,0.219 10 false IGBT: ON


vii.

The illustration below describes the basic control used when the motor generator functions as a generator. The current that is generated sequentially by the 3 phases of the motor generator, which is driven by the wheels, is utilized to charge the HV battery or drive another motor generator.

W101617E19
5.094,5.854 5.302,6.052 0.208,0.198 10 false U 4.625,5.635 4.927,5.854 0.302,0.219 10 false (+) 4.656,6.958 4.958,7.177 0.302,0.219 10 false (-) 5.594,5.854 5.802,6.052 0.208,0.198 10 false V 6.052,5.854 6.26,6.052 0.208,0.198 10 false W 3.458,5.844 3.667,6.042 0.208,0.198 10 false U 3,6.677 3.208,6.875 0.208,0.198 10 false V 3.781,6.625 3.99,6.823 0.208,0.198 10 false W 3,6.896 4.094,7.083 1.094,0.188 10 false Motor Generator 2.229,7.167 2.594,7.385 0.365,0.219 10 false IPM 5.063,3.344 5.271,3.542 0.208,0.198 10 false U 4.635,3.063 4.938,3.281 0.302,0.219 10 false (+) 4.656,4.417 4.958,4.635 0.302,0.219 10 false (-) 5.542,3.344 5.75,3.542 0.208,0.198 10 false V 6.021,3.354 6.229,3.552 0.208,0.198 10 false W 3.469,3.271 3.677,3.469 0.208,0.198 10 false U 3,4.073 3.208,4.271 0.208,0.198 10 false V 3.781,4.063 3.99,4.26 0.208,0.198 10 false W 3,4.396 4.104,4.615 1.104,0.219 10 false Motor Generator 2.25,4.625 2.583,4.813 0.333,0.188 10 false IPM 5.063,0.792 5.271,0.99 0.208,0.198 10 false U 4.635,0.542 4.938,0.76 0.302,0.219 10 false (+) 4.646,1.813 4.948,2.031 0.302,0.219 10 false (-) 5.552,0.802 5.76,1 0.208,0.198 10 false V 6.01,0.802 6.219,1 0.208,0.198 10 false W 3.469,0.74 3.677,0.938 0.208,0.198 10 false U 3,1.552 3.208,1.75 0.208,0.198 10 false V 3.781,1.542 3.99,1.74 0.208,0.198 10 false W 3,1.854 4.115,2.063 1.115,0.208 10 false Motor Generator 2.25,2.083 2.583,2.25 0.333,0.167 10 false IPM



f.

Inverter Control

i.

The inverter converts the direct current from the HV battery into alternating current for MG1 and MG2, or vice versa. In addition, the inverter takes power generated by MG1 and supplies it to MG2. However, the electricity generated by MG1 is converted into the direct current inside the inverter before being converted back into the alternating current by the inverter for use by MG2. This is necessary because the frequency of the alternating current output by MG1 is not appropriate for control of MG2.


ii.

The MG ECU controls the IPMs for switching the three-phase alternating current of MG1 and MG2 in accordance with the signals received from the power management control ECU.


iii.

When the power management control ECU has received an overheating, overcurrent, or voltage fault signal from the MG ECU, the power management control ECU transmits a shut down control signal to the MG ECU, in order to turn off the IPMs.

W101618E32
2.104,3.51 3.396,3.823 1.292,0.313 10 false Boost Converter 2.292,4.625 3.073,4.854 0.781,0.229 10 false HV Battery 3.125,1.198 3.854,1.74 0.729,0.542 10 false Alternating Current 0.229,1.177 1.458,1.375 1.229,0.198 10 false Alternating Current 0.333,3.365 1.469,3.76 1.135,0.396 10 false Maximum Voltage of DC 650 V 0.406,4.219 1.448,4.604 1.042,0.385 10 false Nominal Voltage of DC 201.6 V 0.531,2.958 1.469,3.156 0.938,0.198 10 false Direct Current 4.156,3.531 4.792,3.719 0.635,0.188 10 false MG ECU 3.177,2.99 3.729,3.177 0.552,0.188 10 false Inverter 2.302,2.406 3.167,2.604 0.865,0.198 10 false IPM for MG1 2.552,0.573 2.938,0.771 0.385,0.198 10 false MG1 3.688,2.396 4.573,2.604 0.885,0.208 10 false IPM for MG2 3.938,0.563 4.323,0.75 0.385,0.188 10 false MG2 4.115,4.656 5.854,5.021 1.74,0.365 10 false Power Management Control ECU 5.177,1.844 6.563,2.271 1.385,0.427 10 false Inverter with Converter Assembly 4.531,4.25 6,4.458 1.469,0.208 10 false Serial Communication



g.

Boost Converter Control

i.

The boost converter boosts the HV battery nominal voltage of DC 201.6 V up to a maximum voltage of DC 650 V, in accordance with the signals provided by the power management control ECU via the MG ECU.


ii.

The inverter converts the alternating current generated by MG1 or MG2 into direct current. The boost converter steps down the generated voltage of DC 650 V (maximum voltage) to approximately DC 201.6 V, in accordance with the signals provided by the power management control ECU via the MG ECU.


iii.

The boost converter consists of the boost IPM with built-in IGBTs that perform switching control, the reactor that stores the electrical power and generates the electromotive force, and the capacitor that charges and discharges the boosted high-voltage electricity.

W101619E09
5.344,3.115 5.344,1.427 5.344,1.427 5.229,1.427 true 0.365,1.896 1.125,2.135 0.76,0.24 10 false HV Battery 3.302,2.844 4.042,3.042 0.74,0.198 10 false Boost IPM 6.073,2.813 6.594,3.021 0.521,0.208 10 false Inverter 2.854,1.49 3.771,1.917 0.917,0.427 10 false IGBT2 for Voltage Boost 2.854,0.708 3.76,1.25 0.906,0.542 10 false IGBT1 for Voltage Stepdown 5.031,3.125 5.708,3.344 0.677,0.219 10 false Capacitor 2.042,1.573 2.625,1.771 0.583,0.198 10 false Reactor


iv.

The flow of the boost converter boosting is as described below.

Step Outline
1 IGBT2 turns on, causing the voltage of the HV battery (nominal voltage of DC 201.6 V) to charge the reactor. As a result, the reactor stores the electrical power.
2 IGBT2 turns off, causing the reactor to produce an electromotive force (the current continues to flow from the reactor). This electromotive force causes the voltage to rise to a maximum voltage of DC 650 V. Induced by the electromotive force that is created by the reactor, the current that is flowing from the reactor flows into the inverter and the capacitor at the boosted voltage.
3 IGBT2 turns on again to cause the voltage of the HV battery to charge the reactor. While this happens, by discharging the electrical power (maximum voltage of DC 650 V) stored in the capacitor, electrical power continues to be supplied to the inverter.

W101620E15
5.417,2.323 5.417,1.583 5.417,1.583 5.302,1.583 true 2.094,1.292 2.094,1.125 2.094,1.125 1.979,1.125 true 5.417,5.573 5.417,4.823 5.417,4.823 5.302,4.823 true 2.094,4.51 2.094,4.344 2.094,4.344 1.979,4.344 true 4.844,4.115 4.844,3.583 4.844,3.583 4.958,3.583 true 5.417,8.833 5.417,8.083 5.417,8.083 5.302,8.083 true 5.479,7.354 5.479,6.823 5.479,6.823 5.365,6.823 true 2.094,7.781 2.094,7.615 2.094,7.615 1.979,7.615 true 0.167,1.844 1.198,2.396 1.031,0.552 10 false HV Battery: Nominal Voltage of DC 201.6 V 3.365,2.958 4.104,3.167 0.74,0.208 10 false Boost IPM 6.167,2.917 6.688,3.094 0.521,0.177 10 false Inverter 5,2.354 5.646,2.542 0.646,0.188 10 false Capacitor 1.417,1.01 1.958,1.198 0.542,0.188 10 false Reactor 3.302,1.625 3.771,1.969 0.469,0.344 10 false IGBT2: ON 3.302,0.948 3.781,1.323 0.479,0.375 10 false IGBT1: OFF 0.167,0.167 0.854,0.479 0.688,0.313 12 false Step 1: 0.167,5.104 1.208,5.646 1.042,0.542 10 false HV Battery: Nominal Voltage of DC 201.6 V 3.365,6.188 4.115,6.385 0.75,0.198 10 false Boost IPM 6.167,6.188 6.677,6.385 0.51,0.198 10 false Inverter 5,5.604 5.656,5.813 0.656,0.208 10 false Capacitor 5,3.469 7.031,3.656 2.031,0.188 10 false Maximum Voltage of DC 650 V 1.427,4.24 1.969,4.427 0.542,0.188 10 false Reactor 3.302,4.875 3.771,5.219 0.469,0.344 10 false IGBT2: OFF 3.292,4.198 3.771,4.531 0.479,0.333 10 false IGBT1: OFF 0.167,3.438 0.854,3.75 0.688,0.313 12 false Step 2: 0.177,8.323 1.219,8.885 1.042,0.563 10 false HV Battery: Nominal Voltage of DC 201.6 V 3.365,9.438 4.156,9.635 0.792,0.198 10 false Boost IPM 6.167,9.448 6.698,9.646 0.531,0.198 10 false Inverter 5,8.844 5.656,9.042 0.656,0.198 10 false Capacitor 3.396,6.719 5.365,6.917 1.969,0.198 10 false Maximum Voltage of DC 650 V 3.323,8.104 3.781,8.427 0.458,0.323 10 false IGBT2: ON 3.323,7.427 3.792,7.823 0.469,0.396 10 false IGBT1: OFF 1.427,7.51 1.958,7.708 0.531,0.198 10 false Reactor 0.167,6.531 0.854,6.844 0.688,0.313 12 false Step 3:


v.

The alternating current which is generated by MG1 or MG2 for the purpose of charging the HV battery is converted into direct current (maximum voltage of DC 650 V) by the inverter. Then, the boost converter is used to step down the voltage to approximately DC 201.6 V. This is accomplished by IGBT1 being switched on and off using duty cycle control, intermittently interrupting the electrical power provided to the reactor by the inverter.

W101621E11
1.938,1.688 1.938,1.313 1.938,1.313 1.813,1.313 true 3.938,1.333 3.938,0.365 3.938,0.365 3.813,0.365 true 4.844,1.042 4.844,0.667 4.844,0.667 4.958,0.667 true 3.458,3.313 4.219,3.51 0.76,0.198 10 false Boost IPM 6.125,3.25 6.656,3.458 0.531,0.208 10 false Inverter 2.104,2.021 2.667,2.229 0.563,0.208 10 false Reactor 0.135,1.208 1.813,1.396 1.677,0.188 10 false Approximately DC 201.6 V 1.635,0.229 3.781,0.604 2.146,0.375 10 false IGBT1: ON/OFF Switching Control (Duty Cycle Control) 3.344,1.979 3.813,2.344 0.469,0.365 10 false IGBT2: OFF 5.01,0.563 7.052,0.771 2.042,0.208 10 false Maximum Voltage of DC 650 V 0.156,2.188 1.198,2.76 1.042,0.573 10 false HV Battery: Nominal Voltage of DC 201.6 V



h.

DC-DC Converter Control

i.

The DC-DC converter steps down the HV battery nominal voltage of DC 201.6 V to approximately DC 14 V in order to supply electricity to the electrical components, as well as to recharge the auxiliary battery.


ii.

In order to regulate the output voltage from the DC-DC converter, the power management control ECU transmits an output voltage request signal to the DC-DC converter in response to auxiliary battery temperature sensor signals.

W101622E13
4.042,0.698 5.135,0.896 1.094,0.198 10 false Electrical Loads 1.594,1.135 2.698,1.406 1.104,0.271 10 false DC-DC Converter 3.604,1.698 5.469,2.167 1.865,0.469 10 false Auxiliary Battery Temperature Sensor (Thermistor Assembly) 1.615,2.802 2.208,3.021 0.594,0.219 10 false MG ECU 0.469,2.656 1.208,3.208 0.74,0.552 10 false Inverter with Converter Assembly 6.229,1.854 6.813,2.281 0.583,0.427 10 false Auxiliary Battery 0.458,1.177 1.25,1.417 0.792,0.24 10 false HV Battery 3.188,2.802 3.531,2.969 0.344,0.167 10 false VLO 3.094,3.26 3.531,3.479 0.438,0.219 10 false NODD 3.656,2.802 5.375,3.167 1.719,0.365 10 false Power Management Control ECU



i.

System Main Relay Control

i.

The power management control ECU controls the system main relays to connect and disconnect the high-voltage circuit from the HV battery. The power management control ECU also uses the timing of the operation of the system main relays to monitor the operation of the relay contacts.


ii.

A total of 3 relays, 1 for the positive side (SMRB), and 2 for the negative side (SMRP, SMRG), are provided to ensure proper operation.

W104451E06
1.063,0.594 2.292,0.802 1.229,0.208 10 false Battery Smart Unit 4.229,0.406 5.969,0.813 1.74,0.406 10 false Power Management Control ECU 6.104,1.719 7.125,2.135 1.021,0.417 10 false To Power Cable (Frame Wire) 3.531,2.177 4.01,2.375 0.479,0.198 10 false SMRB 3.531,3.042 3.99,3.229 0.458,0.188 10 false SMRP 3.531,3.917 4.031,4.094 0.5,0.177 10 false SMRG 0.438,2.583 1.208,2.792 0.771,0.208 10 false HV Battery 3.427,4.313 5.958,4.542 2.531,0.229 10 false Hybrid Battery Junction Block Assembly 4.906,2.875 5.573,3.24 0.667,0.365 10 false Precharge Resistor 1.833,2.063 2.833,2.438 1,0.375 10 false Battery Current Sensor 2.667,0.75 4.063,0.948 1.396,0.198 10 false Serial Communication 6.125,3.417 7.115,3.813 0.99,0.396 10 false To Power Cable (Frame Wire)


iii.

When the hybrid system changes to the READY-on state, the power management control ECU turns on SMRB and SMRP in sequence, and applies the current through the precharge resistor. After that, it turns SMRG on, and applies the current by bypassing the precharge resistor. Then it turns SMRP off. As the controlled current is initially allowed to pass through the precharge resistor in this manner, the contact point in the circuit is protected from damage that could be caused by an inrush current.

W101624E08
1.219,0.969 2,1.167 0.781,0.198 10 false SMRB: ON 1.25,1.656 2.073,1.865 0.823,0.208 10 false SMRP: OFF 1.25,2.333 2.094,2.531 0.844,0.198 10 false SMRG: OFF 5.021,0.958 5.771,1.167 0.75,0.208 10 false SMRB: ON 4.99,1.646 5.781,1.854 0.792,0.208 10 false SMRP: ON 4.958,2.323 5.813,2.521 0.854,0.198 10 false SMRG: OFF 1.25,3.802 2.031,4 0.781,0.198 10 false SMRB: ON 1.24,4.49 1.99,4.667 0.75,0.177 10 false SMRP: ON 1.229,5.177 2.031,5.375 0.802,0.198 10 false SMRG: ON 4.979,3.802 5.771,3.99 0.792,0.188 10 false SMRB: ON 4.969,4.49 5.802,4.688 0.833,0.198 10 false SMRP: OFF 5.01,5.167 5.792,5.365 0.781,0.198 10 false SMRG: ON


iv.

When the hybrid system changes to a state other than the READY-on state, the power management control ECU turns SMRG off first. Next, it turns SMRB off after determining whether or not SMRG is operating properly. After that, it turns on SMRP and then off after determining whether or not SMRB is operating properly. As a result, the power management control ECU verifies that the respective relays have been properly turned off.

W101625E03
1.228,0.955 2.082,1.126 0.854,0.172 10 SMRB: ON 1.228,1.639 2.124,1.81 0.896,0.172 10 SMRP: OFF 1.228,2.322 2.124,2.494 0.896,0.172 10 SMRG: OFF 4.977,0.955 5.839,1.126 0.863,0.172 10 SMRB: OFF 4.977,1.639 5.873,1.81 0.896,0.172 10 SMRP: OFF 4.977,2.322 5.873,2.494 0.896,0.172 10 SMRG: OFF 1.228,3.801 2.124,3.973 0.896,0.172 10 SMRB: OFF 1.228,4.485 2.124,4.657 0.896,0.172 10 SMRP: ON 1.228,5.169 2.124,5.341 0.896,0.172 10 SMRG: OFF 4.977,3.801 5.873,3.973 0.896,0.172 10 SMRB: OFF 4.977,4.485 5.873,4.657 0.896,0.172 10 SMRP: OFF 4.977,5.169 5.873,5.341 0.896,0.172 10 SMRG: OFF



j.

Cooling System Control for Inverter with Converter Assembly

i.

The power management control ECU receives the signals from the temperature sensors for the inverter with converter assembly, temperature sensor for MG1 and temperature sensor for MG2. Then, the power management control ECU actuates the inverter water pump assembly over 3 levels using duty cycle control, in order to cool the inverter with converter assembly, MG1 and MG2.


ii.

When the HV coolant temperature rises above a certain level, the power management control ECU transmits a radiator fan drive request signal to the ECM. In response to that signal, the ECM actuates the radiator fan to restrain the HV coolant temperature increase, ensuring the cooling of the inverter with converter assembly, MG1 and MG2.


iii.

The MG ECU converts the temperature sensor signals into digital signals, and transmits them to the power management control ECU via serial communication.

W101626E32
2.927,0.583 3.552,0.802 0.625,0.219 10 false MG ECU 0.438,0.229 0.844,0.417 0.406,0.188 10 false ECM 0.438,0.552 1.875,0.74 1.438,0.188 10 false - Radiator Fan Control 0.979,2.292 3.115,2.51 2.135,0.219 10 false Power Management Control ECU 0.792,4.583 1.375,4.969 0.583,0.385 10 false Auxiliary Battery 1.01,3.917 1.813,4.146 0.802,0.229 10 false IGCT Relay 1.25,1.49 2.479,1.708 1.229,0.219 10 false CAN (Sub Bus 12) 4.156,0.385 6.625,0.771 2.469,0.385 10 false Temperature Sensor (4 Module Temp. / HV Coolant Temp.) 4.323,2.26 6.26,2.469 1.938,0.208 10 false Temperature Sensor (for MG1) 4.323,2.792 6.292,2.99 1.969,0.198 10 false Temperature Sensor (for MG2) 4.094,3.365 6.427,3.573 2.333,0.208 10 false Hybrid Vehicle Transaxle Assembly 4.094,1.333 6.219,1.552 2.125,0.219 10 false Inverter with Converter Assembly 3.26,5.135 5.271,5.344 2.01,0.208 10 false Inverter Water Pump Assembly 2.469,4.26 3.5,4.479 1.031,0.219 10 false Motor Controller 3.281,1.615 4.823,1.854 1.542,0.24 10 false Serial Communication



k.

Cooling System Control for HV Battery

i.

The power management control ECU receives the signals from the HV battery temperature sensors and HV battery intake air temperature sensor. Then, the power management control ECU steplessly actuates the battery cooling blower assembly using duty cycle control, in order to maintain the HV battery temperature within the specified range.


ii.

While the air conditioning system is operating and cooling down the cabin, if there is any leeway in the HV battery temperature, the power management control ECU turns the battery cooling blower assembly off or sets it to a low speed. The purpose of this control is to give priority to cooling down the cabin. If this control is not performed, air taken from the cabin for battery cooling assembly would slow the cooling of the cabin by the air conditioning system.


iii.

The battery smart unit converts the HV battery related signals (voltage, current and temperature) into digital signals, and transmits them to the power management control ECU via serial communication. Also, the battery smart unit detects and transmits the blower speed feedback voltage, which is necessary to perform the cooling system control, to the power management control ECU.

W108486E08
5.698,0.26 6.49,0.802 0.792,0.542 10 false HV Battery Temperature Sensors (6) 4.052,0.271 5.188,0.802 1.135,0.531 10 false HV Battery Intake Air Temperature Sensor (2) 4.833,2.219 6.073,2.458 1.24,0.24 10 false Battery Smart Unit 0.385,0.615 2.656,0.833 2.271,0.219 10 false Air Conditioning Amplifier Assembly 0.531,1.99 2.281,2.396 1.75,0.406 10 false Power Management Control ECU 0.781,4.542 1.979,4.74 1.198,0.198 10 false Auxiliary Battery 0.896,3.677 2.063,3.927 1.167,0.25 10 false BATT FAN Relay 3.958,4.979 6.135,5.177 2.177,0.198 10 false Battery Cooling Blower Assembly 3.167,4.031 4.25,4.271 1.083,0.24 10 false Motor Controller 1.573,1.604 2.802,1.854 1.229,0.25 10 false CAN (Sub Bus 12) 3.406,1.417 4.198,1.635 0.792,0.219 10 false HV Battery 2.51,2.417 3.885,2.625 1.375,0.208 10 false Serial Communication



l.

Regenerative Braking Cooperative Control

i.

The skid control ECU calculates the total braking force needed based on the brake regulator pressure and brake pedal stroke when the driver depresses the brake pedal.


ii.

After calculating the required total braking force, the skid control ECU sends a regenerative braking force request to the power management control ECU. The power management control ECU replies with the amount of actual regenerative braking (regenerative braking control value).


iii.

The power management control ECU uses MG2 to create the negative torque (deceleration force), thus carrying out the regenerative braking.


iv.

The skid control ECU controls the brake actuator solenoid valves and generates wheel cylinder pressure. The pressure that is generated is what remains after the actual regenerative braking control value has been subtracted from the required total braking force.

W105266E28
5.729,1.25 6.396,1.469 0.667,0.219 10 false MG ECU 5.219,0.25 6.604,0.635 1.385,0.385 10 false Inverter with Converter Assembly 3.885,2.76 6.604,3 2.719,0.24 10 false Actual Regenerative Braking Control Value 1.094,2.771 3.292,2.99 2.198,0.219 10 false Regenerative Brake Force Request 0.292,3.167 2.49,3.552 2.198,0.385 10 false Brake Booster with Master Cylinder Assembly 2.938,3.51 4.135,3.75 1.198,0.24 10 false Skid Control ECU 0.531,3.927 1.76,4.302 1.229,0.375 10 false Regulator Pressure Sensor 0.469,4.875 1.875,5.25 1.406,0.375 10 false Accumulator Pressure Sensor 0.458,5.823 2.021,6.188 1.563,0.365 10 false Wheel Cylinder Pressure Sensor 2.917,4.135 4.24,4.531 1.323,0.396 10 false Required Total Brake Force Calculation 2.76,5.135 4.365,5.521 1.604,0.385 10 false Regenerative Brake Force Request Calculation 2.781,6.146 4.375,6.51 1.594,0.365 10 false Required Hydraulic Brake Force Calculation 0.51,6.781 1.552,6.99 1.042,0.208 10 false Solenoid Valves 2.698,0.25 4.448,0.615 1.75,0.365 10 false Power Management Control ECU 2.875,1.271 4.302,1.813 1.427,0.542 10 false MG2 Generation Force (Regenerative Braking Force) Calculation 5.49,2.302 5.854,2.49 0.365,0.188 10 false MG1 6.208,2.292 6.573,2.479 0.365,0.188 10 false MG2 0.385,0.76 1.625,1.01 1.24,0.25 10 false Battery Smart Unit 0.396,1.135 1.823,1.667 1.427,0.531 10 false - HV Battery Condition (Voltage, Current, Temperature) 0.656,7.438 2,7.656 1.344,0.219 10 false : CAN (Sub Bus 12) 3.5,7.438 5,7.656 1.5,0.219 10 false : Serial Communication 5.125,4.281 6.833,4.656 1.708,0.375 10 false Brake Pedal Stroke Sensor Assembly 5.208,6 6.26,6.219 1.052,0.219 10 false Speed Sensors



m.

EV Drive Mode Control

i.

EV drive mode has been provided to reduce vehicle noise, such as when entering or leaving a garage, as well as reducing the production of exhaust fumes in a garage. When the EV drive mode switch is operated by the driver, the power management control ECU uses only MG2 to drive the vehicle if the operating conditions are satisfied.


ii.

When all operating conditions are satisfied, pressing the EV drive mode switch causes the vehicle to enter EV drive mode, and the EV drive mode indicator light will be illuminated. If any operating condition is not satisfied and the EV drive mode switch is pressed, the EV drive mode indicator light flashes 3 times and a buzzer sounds to inform the driver that the EV drive mode switch operation was rejected, and EV drive mode cannot be entered.


iii.

If any condition does not meet the operating conditions while the vehicle is traveling in EV drive mode, in order to inform the driver that EV drive mode will be canceled, the EV drive mode indicator light flashes 3 times and a buzzer sounds.



n.

PWR Mode and ECO Mode Control

i.

During PWR mode, the power management control ECU optimizes acceleration feel by increasing the power output more quickly at the beginning of accelerator pedal operation.


ii.

During ECO mode, the power management control ECU optimizes fuel economy and driving performance by gently generating the motive force in comparison to accelerator pedal operation. At the same time, it supports Eco driving by optimizing the air conditioning performance.

W101629E21
4.281,1.792 4.281,0.823 4.281,0.823 4.458,0.823 true 3.948,1.667 3.948,0.833 3.948,0.833 3.76,0.833 true 4.615,2.771 4.615,1.719 true 0.135,0.146 2.854,0.375 2.719,0.229 12 false Motive Force Output Characteristics: 2.51,0.729 3.75,0.917 1.24,0.188 10 false PWR Mode Control 4.5,0.719 5.521,0.906 1.021,0.188 10 false Normal Control 4.021,2.792 5.292,3.01 1.271,0.219 10 false ECO Mode Control 2.813,3.271 4.646,3.521 1.833,0.25 10 false Accelerator Pedal Opening 1.656,1.844 2.125,2.396 0.469,0.552 10 false Motive Force Output




FUNCTION


a.

Energy Monitor

i.

The energy monitor displayed in the radio and display receiver assembly*1 or navigation receiver assembly*2 shows the energy flow of the hybrid system and the SOC of the HV battery in 8 levels based on information from the power management control ECU.

*1: Models with touch screen system or display audio system

*2: Models with HDD navigation system

W108995E02
4.979,1.906 5.458,2.083 0.479,0.177 10 false *1 (*A) 4.969,4.052 5.552,4.26 0.583,0.208 10 false *2 (*B)

Text in Illustration (LHD Models:)
*A Models with Touch Screen System *B Models with HDD Navigation System
*1 Radio and Display Receiver Assembly *2 Navigation Receiver Assembly

W108466E02
5.042,1.927 5.521,2.104 0.479,0.177 10 false *1 (*A) 5.031,4.063 5.542,4.292 0.51,0.229 10 false *2 (*B)

Text in Illustration (RHD Models:)
*A Models with Touch Screen System or Display Audio System *B Models with HDD Navigation System
*1 Radio and Display Receiver Assembly *2 Navigation Receiver Assembly




CONSTRUCTION


a.

Motor Generator No. 1 (MG1) and Motor Generator No. 2 (MG2)

i.

MG1 and MG2, which are built into the hybrid vehicle transaxle assembly, are compact, lightweight, and highly efficient alternating current permanent magnet motors.


ii.

MG1 and MG2 respectively consist of a stator, stator coil, rotor, permanent magnets, and resolver.


iii.

MG1 charges the HV battery and supplies electrical power to drive MG2. In addition, MG1 regulates the generated electricity to change the its speed, controlling the continuously variable transmission function of the transaxle effectively. MG1 also serves as the starter to start the engine.


iv.

MG2 drives the drive wheels using electrical power from MG1 or the HV battery. In addition, it acts as generator when decelerating to charge the HV battery.

U111620E04
1.417,1.448 2.573,1.448 true 1.417,1.708 2.75,1.708 true 1.417,2.417 2.531,2.417 true 1.406,2.719 2.094,2.719 2.094,2.719 2.771,2.615 true 1.406,3 2.094,3 2.094,3 2.771,2.854 true 4.25,2.896 5.75,2.896 true 4.25,2.594 5.75,2.594 true 4.021,1.917 5.75,1.917 true 4.385,1.563 5.083,1.354 5.083,1.354 5.75,1.354 true 4.281,1.76 5.094,1.625 5.094,1.625 5.75,1.625 true 2.802,0.563 3.073,0.792 0.271,0.229 10 false *1 1.229,1.354 1.5,1.583 0.271,0.229 10 false *3 1.229,1.625 1.5,1.854 0.271,0.229 10 false *4 1.229,2.333 1.5,2.563 0.271,0.229 10 false *5 1.229,2.604 1.5,2.833 0.271,0.229 10 false *6 1.229,2.917 1.5,3.146 0.271,0.229 10 false *7 5.813,1.271 6.083,1.5 0.271,0.229 10 false *3 5.813,1.521 6.083,1.75 0.271,0.229 10 false *4 5.813,1.833 6.083,2.063 0.271,0.229 10 false *5 5.813,2.5 6.083,2.729 0.271,0.229 10 false *6 5.813,2.813 6.083,3.042 0.271,0.229 10 false *7 4.156,0.563 4.427,0.792 0.271,0.229 10 false *2

Text in Illustration
*1 MG2 *2 MG1
*3 Stator Coil *4 Permanent Magnet
*5 Resolver *6 Rotor
*7 Stator - -


v.

When a three-phase alternating current is passed through the three-phase windings of the stator coil, a rotating magnetic field is created in the electric motor. By controlling this rotating magnetic field according to the rotor rotational position and speed, the permanent magnets that are provided in the rotor become attracted by the rotating magnetic field, thus generating torque.


vi.

The generated torque is for all practical purposes proportional to the amount of current, and the rotational speed is controlled by the frequency of the alternating current. Furthermore, a high level of torque, all the way to high speeds, can be generated efficiently by properly controlling the relationship of the rotating magnetic field to the angle of the rotor magnets.


vii.

When the motor is used to generate electricity, the rotation of the rotor creates a rotating magnetic field, which creates current in the phases of the stator coils.

W101634E13
3.771,1.771 3.771,1.688 3.771,1.688 4.823,1.688 true 4.021,1.917 5.125,1.917 true 3.625,3.313 3.625,2.531 true 2.177,1.458 2.958,1.458 true 3.49,0.771 3.76,1 0.271,0.229 10 false *1 3.177,0.333 3.448,0.563 0.271,0.229 10 false *a 1.99,1.354 2.26,1.583 0.271,0.229 10 false *c 5.156,1.813 5.427,2.042 0.271,0.229 10 false *d 3.552,3.344 3.823,3.573 0.271,0.229 10 false *e 3.823,0.51 4.083,0.698 0.26,0.188 10 false *b 2.042,2.396 2.313,2.625 0.271,0.229 10 false *b 4.667,3 4.938,3.229 0.271,0.229 10 false *b 2.24,3.073 2.51,3.302 0.271,0.229 10 false *a 5.125,2.531 5.396,2.76 0.271,0.229 10 false *a 2.427,2.594 2.646,2.792 0.219,0.198 10 false *2 4.563,2.594 4.833,2.823 0.271,0.229 10 false *3 4.865,1.583 5.135,1.813 0.271,0.229 10 false *4

Text in Illustration
*1 Stator Coil (U Phase) *2 Stator Coil (V Phase)
*3 Stator Coil (W Phase) *4 Rotor (Permanent Magnet)
*a From Inverter with Converter Assembly *b Connected internally in the motor
*c Rotating Magnetic Field *d Repulsion
*e Attraction - -

W101635E09
2.646,1.156 2.896,1.375 0.25,0.219 10 false U 2.052,0.938 2.302,1.156 0.25,0.219 10 false (+) 2.073,3.125 2.323,3.344 0.25,0.219 10 false (-) 1.479,2.01 2.01,2.208 0.531,0.198 10 false Current 0.146,0.177 3.688,0.417 3.542,0.24 12 false Three-phase Alternating Current Waveforms: 3.479,1.177 3.729,1.396 0.25,0.219 10 false V 4.302,1.167 4.552,1.385 0.25,0.219 10 false W



b.

Resolver for MG1 and MG2

i.

A resolver is an extremely reliable and compact sensor that precisely detects the magnetic pole position. Knowing the precise position of the magnetic poles of the rotor (MG1 and MG2) is indispensable for ensuring efficient control of MG1 and MG2. MG1 and MG2 each have their own resolver.


ii.

The stator of the resolver contains 3 types of coils: excitation coil A, detection coil S and detection coil C.


iii.

The rotor of the resolver is oval, the distance of the gap between the stator and the rotor varies with the rotation of the rotor.


iv.

The flow of an alternating current into the excitation coil A results in the creation of a constant frequency magnetic field. Using this constant frequency magnetic field, the coil S and coil C will output values that correspond to the position of the rotor. Therefore, the MG ECU detects the absolute position based on the difference between the coil S and coil C output values. Furthermore, the MG ECU calculates the rotational speed based on the amount of change in the position within a given length of time.


v.

The +S and -S pairs of the detection coil S are staggered by 90 degrees. The +C and -C pairs of the detection coil C are also staggered in the same way. The S and C pairs of coils are located 45° from each other.

W101636E09
4.927,0.521 5.135,0.688 0.208,0.167 10 false *5 5.677,1.656 5.906,1.844 0.229,0.188 10 false *1 4.198,1.646 4.438,1.823 0.24,0.177 10 false *1 4.927,0.938 5.167,1.125 0.24,0.188 10 false *3 4.927,2.385 5.146,2.563 0.219,0.177 10 false *3 4.417,1.135 4.656,1.323 0.24,0.188 10 false *4 5.458,2.167 5.656,2.344 0.198,0.177 10 false *4 5.448,1.156 5.667,1.344 0.219,0.188 10 false *2 4.427,2.177 4.635,2.365 0.208,0.188 10 false *2 2.323,4.385 2.51,4.563 0.188,0.177 10 false *1 3.094,4.385 3.292,4.563 0.198,0.177 10 false *3 3.094,5.188 3.333,5.375 0.24,0.188 10 false *4 2.323,5.188 2.552,5.354 0.229,0.167 10 false *2 3.865,4.396 4.073,4.583 0.208,0.188 10 false *1 4.635,4.396 4.854,4.583 0.219,0.188 10 false *3 4.635,5.198 4.854,5.375 0.219,0.177 10 false *4 3.865,5.188 4.083,5.365 0.219,0.177 10 false *2 5.01,1.438 5.25,1.615 0.24,0.177 10 false *6 3.552,0.344 3.823,0.563 0.271,0.219 10 false *a 1.427,3.646 1.698,3.865 0.271,0.219 10 false *b 1.708,4.115 1.979,4.333 0.271,0.219 10 false *c 1.708,4.927 1.979,5.146 0.271,0.219 10 false *d

Text in Illustration
*1 +S (Detection Coil S) *2 +C (Detection Coil C)
*3 -S (Detection Coil S) *4 -C (Detection Coil C)
*5 Excitation Coil A *6 Rotor
*a Image of Resolver Internal Construction *b Electrical Orientation of Resolver Coils
*c Circuit of Detection Coil S *d Circuit of Detection Coil C


vi.

Because excitation coil A is provided with an alternating current at a constant frequency, a constant frequency magnetic field is output to the coils S and C, regardless of the rotor speed. The magnetic field of the excitation coil A is carried to the coils S and C by the rotor. The rotor is oval, and the gap between the stator and the rotor varies with the rotation of the rotor. Due to the variation of the gap, the peak values of the waveforms output by the coils S and C vary in accordance with the position of the rotor.


vii.

The MG ECU constantly monitors these peak values, and connects them to form a virtual waveform. The MG ECU calculates the absolute position of the rotor from the difference between the values of the coils S and C. It determines the rotor direction based on the difference between the phases of the virtual waveform of the coil S and the virtual waveform of the coil C. Furthermore, the MG ECU calculates the rotational speed based on the amount of change in the rotor position within a given length of time.


viii.

The diagrams below illustrate the waveforms that are output at coils A, S and C when the rotor makes a positive rotation of 180° from a certain position.

W101637E19
3.531,3.26 3.531,2.885 3.531,2.885 3.635,2.885 true 2.385,5.438 2.385,5.052 2.385,5.052 2.49,5.052 true 0.438,1.438 1.583,1.656 1.146,0.219 10 false Excitation Coil A 0.438,3.615 1.521,3.844 1.083,0.229 10 false Detection Coil S 3.677,2.771 4.865,2.99 1.188,0.219 10 false Virtual Waveform 0.438,5.823 1.531,6.031 1.094,0.208 10 false Detection Coil C 6.271,7.083 6.708,7.313 0.438,0.229 10 false 180° 5.125,7.083 5.563,7.313 0.438,0.229 10 false 135° 4,7.083 4.438,7.313 0.438,0.229 10 false 90° 2.865,7.083 3.302,7.313 0.438,0.229 10 false 45° 1.771,7.083 2.208,7.313 0.438,0.229 10 false 0° 1.573,6.646 1.792,6.875 0.219,0.229 10 false (-) 1.563,4.99 1.792,5.208 0.229,0.219 10 false (+) 1.573,4.479 1.792,4.677 0.219,0.198 10 false (-) 1.563,2.823 1.781,3.052 0.219,0.229 10 false (+) 1.573,2.281 1.792,2.51 0.219,0.229 10 false (-) 1.563,0.646 1.813,0.844 0.25,0.198 10 false (+) 2.531,4.948 3.719,5.146 1.188,0.198 10 false Virtual Waveform



c.

Temperature Sensor for MG1 and MG2

i.

The temperature sensors are used to detect the temperature of the MG1 and MG2 stators.


ii.

The power management control ECU optimally controls MG1 and MG2 according to the signals from each temperature sensor.

W101125E10
0.167,0.323 3.208,0.563 3.042,0.24 12 false Characteristics of Temperature Sensor: 0.792,1.802 1.583,2.01 0.792,0.208 10 false Resistance 3.115,3 4,3.219 0.885,0.219 10 false Temperature



d.

Inverter with Converter Assembly

i.

A compact, lightweight inverter with converter assembly, in which the MG ECU, inverter, boost converter, and DC-DC converter are integrated, is used. The inverter and boost converter primarily consist of Intelligent Power Modules (IPMs), a reactor, and capacitor. The IPM is an integrated power module consisting of a signal processor, protective function processor, and Insulated Gate Bipolar Transistors (IGBTs).


ii.

The inverter with converter assembly ensures heat dissipation through use of a water-cooled cooling system that is isolated from the engine cooling system.


iii.

As a safety measure due to the use of high-voltage electricity, interlock switches are provided, which shut off the system main relays via the power management control ECU when the inverter terminal cover is removed, or the HV battery power cable connector is disconnected.

U155209E03
1.927,1.229 1.115,1.229 true 1.729,2.156 0.927,2.156 true 3.802,2.385 3.396,0.427 3.396,0.427 3.031,0.427 true 0.906,1.125 1.115,1.302 0.208,0.177 10 false *7 2.354,3.948 2.635,4.156 0.281,0.208 10 false *5 3.406,4.115 3.688,4.323 0.281,0.208 10 false *4 6.073,2.333 6.354,2.542 0.281,0.208 10 false *3 6.073,1.885 6.354,2.094 0.281,0.208 10 false *2 0.729,2.052 0.948,2.25 0.219,0.198 10 false *1 2.844,0.344 3.125,0.552 0.281,0.208 10 false *6

Text in Illustration
*1 Case with Built-in Capacitor *2 MG ECU
*3 Intelligent Power Modules (IPMs) *4 Reactor
*5 DC-DC Converter *6 Interlock Switch (For Power Cable Connector)
*7 Interlock Switch (For Inverter Terminal Cover) - -
V100135

HV Coolant Inlet
V100136

HV Coolant Outlet


iv.

The inverter uses the IPM to perform switching control. The IPMs for MG1 and MG2 each have a bridge circuit consisting of IGBTs. The IPM for MG1 uses 6 IGBTs, one for each arm, and MG2 uses 6 pairs of IGBTs, two in parallel for each arm.


v.

The boost converter uses a boost IPM to perform switching control, a reactor to act as an inductor, and a capacitor to accumulate and store electricity. The boost IPM uses IGBT2 for boosting voltage, and IGBT1 for reducing voltage.

W101639E12
1.063,4.083 1.552,4.333 0.49,0.25 10 false IGBT 1.479,0.583 1.969,0.833 0.49,0.25 10 false MG1 1.031,6.667 1.5,6.885 0.469,0.219 10 false IGBT1 1.385,1.323 1.625,1.573 0.24,0.25 10 false U 1.677,1.323 1.917,1.573 0.24,0.25 10 false V 1.969,1.323 2.208,1.573 0.24,0.25 10 false W 1.875,6.667 2.448,6.917 0.573,0.25 10 false IGBT2 1.24,4.688 2.167,4.938 0.927,0.25 10 false IPM for MG1 3.146,4.677 4.073,4.927 0.927,0.25 10 false IPM for MG2* 0.719,7.021 1.646,7.271 0.927,0.25 10 false Boost IPM* 0.844,7.406 1.406,7.656 0.563,0.25 10 false Reactor 1.354,5.573 1.99,5.802 0.635,0.229 10 false Capacitor 3.979,5.052 4.885,5.302 0.906,0.25 10 false Inverter 3.292,6.344 3.969,6.594 0.677,0.25 10 false MG ECU 1.74,8.792 2.458,9.042 0.719,0.25 10 false HV Battery 0.531,7.833 1.635,8.281 1.104,0.448 10 false Boost Converter 3.188,7.188 4.375,7.438 1.188,0.25 10 false DC-DC Converter 3.021,8.927 4.438,9.344 1.417,0.417 10 false Compressor with Motor Assembly 4.896,1.698 6.26,2.219 1.365,0.521 10 false Inverter with Converter Assembly 3.385,0.583 3.875,0.833 0.49,0.25 10 false MG2 3.302,1.323 3.542,1.573 0.24,0.25 10 false U 3.594,1.323 3.833,1.573 0.24,0.25 10 false V 3.875,1.313 4.115,1.563 0.24,0.25 10 false W 5.417,6.323 6.677,6.76 1.26,0.438 10 false Power Management Control ECU 5.063,8.625 7,9.229 1.938,0.604 10 false *: Single IGBTs have been used to represent pairs of IGBTs for simplicity.



e.

MG ECU

i.

The MG ECU is provided in the inverter with converter assembly. In accordance with the signals received from the power management control ECU, the MG ECU controls the inverter and boost converter in order to drive MG1 or MG2 or cause them to generate electricity.


ii.

The MG ECU transmits information that is required for vehicle control, such as the atmospheric pressure, inverter temperature and any failure information, to the power management control ECU. The MG ECU receives information that is required for controlling MG1 and MG2, such as the required motive force and the temperature of MG1 and MG2, from the power management control ECU.



f.

Atmospheric Pressure Sensor

i.

An atmospheric pressure sensor is provided on the MG ECU board.


ii.

This sensor detects the atmospheric pressure and transmits a signal to the MG ECU to allow corrections that correspond to the usage environment.



g.

Temperature Sensor for Inverter with Converter Assembly

i.

For the inverter with converter assembly, there are 5 different temperature sensors; 2 of them are located at the IPMs for MG1 and MG2, 2 of them are located at the boost converter, and the remaining sensor is located at the HV coolant passage.


ii.

These sensors detect the temperatures at areas inside the inverter with converter assembly, and transmit that temperature information to the power management control ECU via the MG ECU. The power management control ECU optimizes the cooling system according to the temperature information, maintaining the output performance of the inverter with converter assembly.

W101640E06
1.271,0.948 2.198,1.198 0.927,0.25 10 IPM for MG1 3.167,1.063 4.094,1.313 0.927,0.25 10 IPM for MG2 4,1.688 4.906,1.938 0.906,0.25 10 Inverter 3.188,2.948 3.865,3.198 0.677,0.25 10 MG ECU 1.802,1.417 2.063,1.667 0.26,0.25 10 *1 3.708,1.417 3.969,1.667 0.26,0.25 10 *2 1.313,2.229 1.573,2.479 0.26,0.25 10 *3 2.281,2.24 2.542,2.49 0.26,0.25 10 *4 4.188,2.292 4.448,2.542 0.26,0.25 10 *5 0.594,3.656 1.698,4.104 1.104,0.448 10 Boost Converter 1.521,4.302 4.615,4.583 3.094,0.281 10 Inverter with Converter Assembly 0.427,4.646 3.115,4.906 2.688,0.26 10 *1: Temperature Sensor on IPM for MG1 0.427,5.021 3.115,5.281 2.688,0.26 10 *2: Temperature Sensor on IPM for MG2 0.427,5.406 3.604,5.813 3.177,0.406 10 *3: Temperature Sensor on Boost IPM (Upper) 3.771,4.646 6.896,4.948 3.125,0.302 10 *4: Temperature Sensor on Boost IPM (Lower) 3.771,5.01 6.208,5.271 2.438,0.26 10 *5: HV Coolant Temperature Sensor 5.083,2.083 6.333,2.354 1.25,0.271 10 HV Coolant Flow 5.438,2.781 6.677,3.573 1.24,0.792 10 Power Management Control ECU 0.698,3.281 1.625,3.531 0.927,0.25 10 Boost IPM



h.

Inverter Current Sensor

i.

The inverter current sensors detect the amperage of the three-phase alternating current that actuates MG1 and MG2. This actual amperage is used as feedback by the MG ECU.


ii.

Current sensors are used for the current sent to the three-phase windings of MG1 and MG2. They are located in the inverter with converter assembly for the V and W phases of each motor generator. Current that flows through the U phase winding flows through the V phase or W phase winding, thus the U phase amperage can be measured even if a current sensor is not set in the U phase winding.

W101641E24
3.438,1.458 3.271,0.427 3.271,0.427 2.792,0.427 true 3.667,1.656 3.865,0.427 3.865,0.427 4.198,0.427 true 3.292,2.865 3.969,3.115 0.677,0.25 10 false MG ECU 1.531,6.583 1.99,6.833 0.458,0.25 10 false MG1 1.635,4.781 1.833,5 0.198,0.219 10 false 9 1.635,5.531 1.833,5.75 0.198,0.219 10 false 5 1.958,6.583 2.323,6.771 0.365,0.188 10 false -200 4.083,6.583 4.313,6.781 0.229,0.198 10 false 0 5.979,6.573 6.323,6.771 0.344,0.198 10 false 200 1.531,6.792 1.917,7 0.385,0.208 10 false MG2 1.958,6.792 2.375,7.042 0.417,0.25 10 false -350 5.979,6.792 6.25,7 0.271,0.208 10 false 350 1.625,6.302 1.833,6.5 0.208,0.198 10 false 1 4.844,0.969 5.052,1.167 0.208,0.198 10 false U 4.396,1.75 4.604,1.948 0.208,0.198 10 false V 5.208,1.729 5.417,1.927 0.208,0.198 10 false W 4.135,2.063 5.188,2.26 1.052,0.198 10 false Motor Generator 0.198,3.917 3.323,4.177 3.125,0.26 12 false Characteristics of Inverter Current Sensor: 4.24,0.323 5.781,0.542 1.542,0.219 10 false Inverter Current Sensor 2.177,2.406 2.74,2.615 0.563,0.208 10 false Inverter 0.542,5.427 1.479,5.802 0.938,0.375 10 false Sensor Output Voltage (V) 3.802,7.313 4.75,7.583 0.948,0.271 10 false Current (A) 1.313,0.313 2.771,0.531 1.458,0.219 10 false Inverter Current Sensor



i.

HV Battery Assembly

i.

The HV battery assembly mainly consists of 2 hybrid battery stacks, a hybrid vehicle junction block assembly, a battery cooling blower assembly, a battery smart unit and a service plug grip.


ii.

The battery cooling blower assembly is used as a dedicated cooling system to ensure that the HV battery performs properly, despite it generating significant heat during the repetitive charge and discharge cycles.

W108455E02
5.063,2.729 5.219,2.135 5.219,2.135 5.677,2.135 true 2.802,5.219 2.396,5.5 2.396,5.5 2.396,6.24 true 1.583,2.802 1.521,2.448 1.521,2.448 1.292,2.448 true 2.5,3.177 2.708,3.177 true 1.552,4.271 1.552,4.917 true 6.104,5.281 6.104,6.021 true 3.521,5.792 3.521,6.292 true 1.031,0.875 0.906,0.49 0.906,0.49 0.573,0.49 true 1.646,2.052 1.552,1.771 1.552,1.771 1.271,1.771 true 4.229,1.396 4.135,1.052 4.135,1.052 3.865,1.052 true 5.708,2.042 6,2.271 0.292,0.229 10 false *6 2.323,6.271 2.615,6.5 0.292,0.229 10 false *9 0.365,0.406 0.656,0.635 0.292,0.229 10 false *1 1.094,1.688 1.385,1.917 0.292,0.229 10 false *2 1.115,2.365 1.365,2.552 0.25,0.188 10 false *3 3.677,0.948 3.969,1.177 0.292,0.229 10 false *4 2.333,3.094 2.625,3.323 0.292,0.229 10 false *5 1.49,4.938 1.781,5.167 0.292,0.229 10 false *8 6.042,6.052 6.333,6.281 0.292,0.229 10 false *7 3.417,6.302 3.708,6.531 0.292,0.229 10 false *10

Text in Illustration
*1 No. 1 Hybrid Battery Shield Sub-assembly *2 No .5 Hybrid Battery Shield Panel
*3 No. 4 Hybrid Vehicle Battery Carrier Bracket Sub-assembly *4 Hybrid Battery Cover Sub-assembly
*5 Service Plug Grip *6 HV Supply Battery Assembly
*7 HV Battery Cover Sub-assembly *8 Hybrid Battery Junction Block Assembly
*9 Battery Smart Unit *10 No. 2 Hybrid Battery Shield Sub-assembly


iii.

Compact, lightweight 3.6 V lithium-ion battery cells are used in order to generate high power output.

W108477E02
3.177,0.844 3.052,0.656 3.052,0.656 2.719,0.656 true 3.969,0.375 3.844,0.177 3.844,0.177 3.51,0.177 true 3.333,0.083 3.625,0.313 0.292,0.229 10 false *2 2.542,0.573 2.833,0.802 0.292,0.229 10 false *1

Text in Illustration
*1 Positive Terminal *2 Negative Terminal


iv.

The 28 lithium-ion battery cells provided for each hybrid battery stack are connected in series in a bus bar module.


v.

The HV battery consists of 2 hybrid battery stacks. They are connected to each other in series through bus bar modules and wiring harness.

W108456E04
3.698,0.969 6.25,1.313 2.552,0.344 10 false Hybrid Battery Stack (Lithium-ion Battery Cell X 28) 3.698,2.333 6.26,2.698 2.563,0.365 10 false Hybrid Battery Stack (Lithium-ion Battery Cell X 28) 1.177,1.844 1.635,2.052 0.458,0.208 10 false SMRs 2.281,0.885 2.917,1.26 0.635,0.375 10 false Service Plug Grip 0.635,3.208 1.823,3.417 1.188,0.208 10 false : Bus Bar Module 0.896,0.76 1.833,1.344 0.938,0.583 10 false Hybrid Battery Junction Block Assembly 0.021,1.521 0.5,2.354 0.479,0.833 10 false To Power Cable (Frame Wire) 4.427,3.292 5.479,3.51 1.052,0.219 10 false Hybrid Battery



j.

HV Battery Temperature Sensor and HV Battery Intake Air Temperature Sensor

i.

6 thermistor type battery temperature sensors are provided in the HV battery to detect the temperature of the HV battery.


ii.

2 thermistor type intake air temperature sensors are provided to detect the temperature of the cooling air.


iii.

The power management control ECU optimally controls the cooling system so that the HV battery temperature and the cooling air temperature can be within a specified range according to the temperature information that is received via the battery smart unit.

W108457E04
1.813,1.104 1.698,0.563 1.698,0.563 1.365,0.563 true 2.563,0.917 2.448,0.531 2.448,0.531 2.115,0.531 true 3.885,0.646 3.719,0.271 3.719,0.271 3.26,0.271 true 1.792,1.927 1.792,3.177 true 2.531,1.74 2.531,2.979 true 3.875,1.479 3.875,2.719 true 4.531,4.583 4.854,4.896 4.854,4.896 4.854,5.479 true 4.458,3.688 3.24,4 3.24,4 3.24,4.625 true 1.708,3.198 2,3.427 0.292,0.229 10 false *2 2.448,3 2.74,3.229 0.292,0.229 10 false *2 3.792,2.74 4.083,2.969 0.292,0.229 10 false *2 3.167,4.635 3.458,4.865 0.292,0.229 10 false *3 4.792,5.49 5.083,5.719 0.292,0.229 10 false *3 3.073,0.177 3.313,0.354 0.24,0.177 10 false *1 1.927,0.427 2.167,0.625 0.24,0.198 10 false *1 1.198,0.458 1.438,0.656 0.24,0.198 10 false *1

Text in Illustration
*1 HV Battery Temperature Sensor
(For Detecting Upper HV Battery Stack Temperature)
*2 HV Battery Temperature Sensor
(For Detecting Lower HV Battery Stack Temperature)
*3 HV Battery Intake Air Temperature Sensor - -



k.

Hybrid Battery Junction Block Assembly

i.

The hybrid battery junction block assembly consists of the System Main Relays (SMRs), precharge resistor and battery current sensor.


ii.

The SMRs are relays that connect and disconnect the HV battery and power cable (frame wire) in accordance with the signal from the power management control ECU. 3 relays are provided; SMRB for the battery positive (+) side, SMRG for the battery negative (-) side, and SMRP for pre-charging.

W101645E06
1.573,1.885 2.448,1.885 true 1.573,1.542 2.979,1.542 true 3.115,1 2.865,0.604 2.865,0.604 2.708,0.604 true 3.5,0.781 3.25,0.385 3.25,0.385 3.094,0.385 true 4.229,1.24 4.563,0.563 4.563,0.563 4.76,0.563 true 1.396,1.802 1.667,2.021 0.271,0.219 10 false *1 1.396,1.448 1.667,1.667 0.271,0.219 10 false *2 2.51,0.51 2.781,0.729 0.271,0.219 10 false *3 2.917,0.302 3.188,0.521 0.271,0.219 10 false *4 4.802,0.469 5.073,0.688 0.271,0.219 10 false *5

Text in Illustration
*1 Battery Current Sensor *2 SMRP
*3 SMRG *4 SMRB
*5 Precharge Resistor - -



l.

Battery Current Sensor

i.

A battery current sensor, which is built into the hybrid battery junction block assembly, is used to detect the HV battery charging and discharging amperage.


ii.

The power management control ECU optimally controls the hybrid system so that the SOC of the HV battery can always be within a specified range according to the amperage information that is received via the battery smart unit.

W103002E04
2.24,3.885 2.542,4.135 0.302,0.25 10 false 4.5 2.24,4.75 2.542,5 0.302,0.25 10 false 2.2 2.24,4.521 2.542,4.771 0.302,0.25 10 false 2.8 5.323,5.75 5.74,6 0.417,0.25 10 false 230 3.875,5.75 4.083,5.917 0.208,0.167 10 false 0 2.625,5.74 3.042,5.99 0.417,0.25 10 false -170 5.646,6.198 6.573,6.448 0.927,0.25 10 false Discharging 2,6.177 2.615,6.396 0.615,0.219 10 false Charging 2.24,5.406 2.542,5.656 0.302,0.25 10 false 0.5 0.156,3.104 3.792,3.406 3.635,0.302 12 false Characteristics of Battery Current Sensor: 1.115,4.563 2.052,4.958 0.938,0.396 10 false Sensor Output Voltage (V) 3.792,6.375 4.573,6.583 0.781,0.208 10 false Current (A) 5.729,1.521 6.51,1.729 0.781,0.208 10 false HV Battery 4.354,0.771 5.344,1.146 0.99,0.375 10 false Battery Current Sensor 2.448,0.219 3.74,0.427 1.292,0.208 10 false Discharging Current 2.271,1.01 2.583,1.198 0.313,0.188 10 false VIB 2.271,1.323 2.552,1.51 0.281,0.188 10 false IB0 2.271,1.635 2.552,1.813 0.281,0.177 10 false IB1 2.271,1.948 2.563,2.115 0.292,0.167 10 false GIB 4.521,0.208 5.646,0.417 1.125,0.208 10 false Charging Current 1.271,1.375 2.177,1.76 0.906,0.385 10 false Battery Smart Unit 3.281,4.083 3.615,4.313 0.333,0.229 10 false IB0 4.76,4.083 5.042,4.26 0.281,0.177 10 false IB1



m.

Battery Smart Unit

i.

The battery smart unit monitors the conditions of the HV battery such as voltage, current and temperature, and transmits this information to the power management control ECU.


ii.

Also, the battery smart unit detects and transmits the blower speed feedback voltage which is necessary to perform the cooling system control, to the power management control ECU.


iii.

A leakage detection circuit is provided in the battery smart unit in order to detect any electrical leakage from the HV battery or high-voltage circuit.


iv.

The battery smart unit converts these signals into digital signals and transmits them to the power management control ECU via serial communication.


v.

When the power switch is turned off, the battery smart unit equalizes the voltage of each battery cell in the HV battery to use the HV battery output effectively.



n.

Service Plug Grip

i.

The service plug grip is connected in the middle of the HV battery stack circuit and is used for manually shutting off the high-voltage circuit. This ensures safety during service.


ii.

The main fuse for the high-voltage circuit is provided inside of the service plug grip.


iii.

An interlock switch is provided on the service plug grip. When the grip section is unlocked, the interlock switch is turned off and the power management control ECU shuts off the system main relays. However, to ensure safety, make sure to turn the power switch off before removing the service plug grip.

W101648E15
2.229,2.719 2.135,2.719 2.135,2.719 1.833,2.531 true 1.135,1.844 1.24,1.844 1.24,1.844 1.542,2.031 true 4.49,0.75 5.26,0.979 0.771,0.229 10 false HV Battery 4.281,3 5.417,3.24 1.135,0.24 10 false Service Plug Grip 5.406,2.583 6.51,2.802 1.104,0.219 10 false Interlock Switch 2.271,2.604 3.313,2.823 1.042,0.219 10 false Interlock Switch 4.5,2.615 5.24,2.844 0.74,0.229 10 false Main Fuse 0.427,1.729 1.135,1.917 0.708,0.188 10 false Main Fuse

CAUTION:

For further details on how to handle the service plug grip and other safety cautions, refer to the Repair Manual.




o.

Power Cable (Frame Wire)

i.

The power cable (frame wire) is a set of high-voltage, high-amperage cables that connect the HV battery with the inverter with converter assembly, the inverter with converter assembly with MG1 and MG2, and the inverter with converter assembly with the compressor with motor assembly.


ii.

The power cable (frame wire) is made of shielded cables in order to reduce electromagnetic interference.


iii.

For identification purposes, the high-voltage wiring harness and connectors are color-coded orange to distinguish them from those of the ordinary low-voltage wiring.

W108462E03
1.198,1.125 1.396,1.323 0.198,0.198 10 false *1 0.948,2.177 1.177,2.354 0.229,0.177 10 false *2 1.667,3.042 1.896,3.208 0.229,0.167 10 false *3 1.667,2.427 1.854,2.625 0.188,0.198 10 false *4 1.667,2.708 1.854,2.896 0.188,0.188 10 false *5 2.698,1.781 2.927,1.969 0.229,0.188 10 false *6 3.865,1.781 4.156,2.01 0.292,0.229 10 false *7 3.052,2.021 3.25,2.198 0.198,0.177 10 false *8

Text in Illustration
*1 Compressor with Motor Assembly *2 Inverter with Converter Assembly
*3 Hybrid Vehicle Transaxle Assembly *4 MG1
*5 MG2 *6 Hybrid Battery Junction Block Assembly
*7 HV Battery Assembly *8 Service Plug Grip
V100143

Power Cable (Frame Wire) - -



p.

Inverter Water Pump Assembly

i.

A compact and highly efficient electric type inverter water pump assembly is used.


ii.

A high output brushless type motor is used for the pump motor, furthermore, bearings that support the shaft at both ends are employed, thus suppressing noise and vibration.


iii.

The pump motor is controlled over 3 levels by the duty cycle signal from the power management control ECU.

W103896E08
3.24,1.688 2.635,0.75 2.635,0.75 2.115,0.75 true 2.958,2.719 1.802,2.719 true 3.229,2.448 1.802,2.448 true 3.469,1.979 2.104,1.979 true 3.573,2.229 5.083,2.229 true 3.469,2.656 3.208,3.302 3.208,3.302 2.135,3.302 true 4.052,3.302 4.146,3.49 4.146,3.49 4.802,3.49 true 1.927,0.656 2.115,0.875 0.188,0.219 10 false *1 1.927,3.208 2.115,3.427 0.188,0.219 10 false *2 1.927,1.885 2.115,2.104 0.188,0.219 10 false *2 1.573,2.354 1.76,2.573 0.188,0.219 10 false *3 1.573,2.625 1.76,2.844 0.188,0.219 10 false *4 4.833,3.385 5.021,3.604 0.188,0.219 10 false *5 5.115,2.125 5.302,2.344 0.188,0.219 10 false *6

Text in Illustration
*1 Impeller *2 Bearing
*3 Magnet *4 Coil
*5 Motor Controller *6 Shaft
V100135

HV Coolant Inlet
V100136

HV Coolant Outlet



q.

Battery Cooling Blower Assembly

i.

A compact and highly efficient battery cooling blower assembly is used.


ii.

A high output brushless type motor is used for the blower motor, and the inner shape of the blower case has been optimized. As a result, blower noise is reduced.


iii.

The blower motor has a built-in motor controller, and is controlled in a variable manner by the duty cycle signal from the power management control ECU.



r.

Auxiliary Battery Temperature Sensor (Thermistor Assembly)

i.

The auxiliary battery temperature sensor (thermistor assembly) detects the auxiliary battery temperature, and transmits temperature signals to the power management control ECU.


ii.

Based on the signal from the sensor, in order to maintain the optimal charging state appropriate to the auxiliary battery temperature, the power management control ECU regulates the output voltage from the DC-DC converter.

W101148E03
2.739,2.371 4.082,2.572 1.343,0.201 10 Battery Temperature 0.934,1.201 1.686,1.402 0.752,0.201 10 Resistance 1.403,0.346 1.753,0.547 0.349,0.201 10 High 1.417,2.21 1.767,2.411 0.349,0.201 10 Low 4.82,2.21 5.322,2.411 0.502,0.201 10 High 1.56,0.084 1.917,0.282 0.358,0.199 10 (kΩ) 5.282,2.168 5.784,2.369 0.502,0.201 10 (°C)



s.

Accelerator Pedal Sensor Assembly

i.

The non-contact type accelerator pedal sensor assembly uses a Hall IC.


ii.

A magnetic yoke is mounted at the base of the accelerator pedal arm. This yoke rotates around the Hall IC in accordance with the amount of effort that is applied to the accelerator pedal. The Hall IC converts the changes in the magnetic flux that occur into electrical signals, and outputs accelerator pedal position signals to the power management control ECU.


iii.

The Hall IC contains 2 circuits, one for the main signal, and one for the sub signal. It converts the accelerator pedal position (angle) into electric signals that have differing characteristics and outputs them to the power management control ECU.

W101146E09
2.802,1.469 2.802,2.313 true 3.854,1.458 3.854,2.313 true 4.146,2.031 4.146,2.313 true 2.719,2.333 2.927,2.542 0.208,0.208 10 false *1 3.771,2.333 3.979,2.542 0.208,0.208 10 false *2 4.083,2.333 4.292,2.542 0.208,0.208 10 false *3

Text in Illustration
*1 Hall IC *2 Magnetic Yoke
*3 Accelerator Pedal Arm - -

W101653E24
1.979,4.146 2.281,4.396 0.302,0.25 10 false 5 1.729,6.125 2.656,6.375 0.927,0.25 10 false Fully Closed 5.146,6.146 6.021,6.396 0.875,0.25 10 false Fully Open 1.979,5.792 2.281,6.042 0.302,0.25 10 false 0 0.156,3.563 4.365,3.865 4.208,0.302 12 false Characteristics of Accelerator Pedal Sensor Assembly: 0.875,4.906 1.823,5.323 0.948,0.417 10 false Sensor Output Voltage (V) 2.76,6.375 4.948,6.615 2.188,0.24 10 false Accelerator Pedal Position (Angle) 1.063,2.958 3.354,3.167 2.292,0.208 10 false Accelerator Pedal Sensor Assembly 2,1.156 2.469,1.375 0.469,0.219 10 false Hall IC 2,1.635 2.469,1.833 0.469,0.198 10 false Hall IC 1.979,0.729 2.49,0.938 0.51,0.208 10 false Magnet 3.667,0.5 4.198,0.719 0.531,0.219 10 false VPA1 3.917,5.25 4.448,5.469 0.531,0.219 10 false VPA1 3.76,0.865 4.292,1.083 0.531,0.219 10 false EP1 3.667,1.229 4.198,1.448 0.531,0.219 10 false VCP1 3.667,1.573 4.198,1.792 0.531,0.219 10 false VPA2 3.24,4.823 3.771,5.042 0.531,0.219 10 false VPA2 3.76,1.917 4.292,2.135 0.531,0.219 10 false EP2 3.667,2.271 4.198,2.49 0.531,0.219 10 false VCP2 1.979,2.115 2.469,2.313 0.49,0.198 10 false Magnet 4.479,1.052 5.75,1.417 1.271,0.365 10 false Power Management Control ECU




OPERATION


a.

Operation of Hybrid Vehicle

i.

The hybrid system uses motive force provided by the engine and MG2, and it uses MG1 as a generator. The system optimally combines these forces in accordance with various driving conditions.


ii.

The power management control ECU constantly monitors the engine coolant temperature, SOC, HV battery temperature and electrical load conditions. If any of the monitoring conditions fails to satisfy the requirements, and when the vehicle is in the READY-on state and the shift position is any position other than N, the power management control ECU starts the engine.


iii.

The hybrid system drives the vehicle by optimally combining the operations of the engine, MG1 and MG2 in accordance with the driving conditions listed below. The vehicle conditions listed below are examples of typical vehicle driving conditions.

W101655E31
0.427,0.438 1,0.677 0.573,0.24 10 false Forward 0.427,2.24 1.115,2.5 0.688,0.26 10 false Reverse 2.438,2.25 3.24,2.51 0.802,0.26 10 false Flat Road 1.302,1.75 1.521,2.01 0.219,0.26 10 false A 1.927,1.75 2.146,2.01 0.219,0.26 10 false B 2.688,1.75 2.906,2.01 0.219,0.26 10 false C 3.5,1.75 3.719,2.01 0.219,0.26 10 false D 4.469,1.75 4.688,2.01 0.219,0.26 10 false E 5.729,1.5 5.917,1.667 0.188,0.167 10 false F 5.479,2.26 6.125,2.458 0.646,0.198 10 false Flat Road 4.083,2.25 5,2.458 0.917,0.208 10 false Downhill Road 6.354,1.75 6.833,2.01 0.479,0.26 10 false Time 0.396,1.5 0.917,1.969 0.521,0.469 10 false Vehicle Speed

Driving Condition
A READY-on State
B Starting Off
C Constant-speed Cruising
D During Full Throttle Acceleration
E During Deceleration
F During Reverse



b.

How to Read a Nomographic Chart

i.

The nomographic chart below gives a visual representation of the planetary gear rotation direction, rotational speed and torque balance.


ii.

In the nomographic chart, a straight line is used to represent the relationship between the rotation directions and rotational speeds of the 3 gears in the planetary gear. The rotational speed of each gear is indicated by the distance from the 0 rpm point. Due to the structure of the planetary gear, the relationship between the rotational speeds of the 3 gears is always expressed by a straight line.


iii.

The nomographic charts and the illustrations of the geartrain operation for each vehicle driving condition shown on the following descriptions are examples only. The examples shown are "snapshots", normal system operation is a constantly changing blend of conditions and system reactions to suit those conditions.

W104326E20
4.865,2.865 4.865,2.094 4.865,2.094 5.052,2.094 true 6.25,2.854 6.25,2.188 6.25,2.188 6.135,2.188 true 5.427,0.813 5.427,0.406 5.427,0.406 5.542,0.406 true 4.396,2.875 5.573,3.146 1.177,0.271 10 false Sun Gear (MG1) 5.594,0.302 6.896,0.51 1.302,0.208 10 false Ring Gear (Output)* 5.646,2.865 6.844,3.146 1.198,0.281 10 false Carrier (Engine) 0.104,3.344 4.969,3.552 4.865,0.208 10 false *: MG2 acts on the ring gear via the motor speed reduction planetary gear unit. 0.323,1.927 0.958,2.313 0.635,0.385 10 false Sun Gear (MG1) 0.146,1.24 0.583,1.458 0.438,0.219 10 false 0 rpm 0.385,0.698 0.708,0.906 0.323,0.208 10 false (+) 1.302,0.698 1.625,0.906 0.323,0.208 10 false (+) 1.896,0.688 2.219,0.896 0.323,0.208 10 false (+) 3.354,1.719 3.604,1.927 0.25,0.208 10 false (+) 0.417,1.74 0.615,1.948 0.198,0.208 10 false (-) 1.313,1.729 1.552,1.938 0.24,0.208 10 false (-) 1.896,1.719 2.146,1.927 0.25,0.208 10 false (-) 3.354,0.708 3.615,0.948 0.26,0.24 10 false (-) 3.26,1.927 3.896,2.302 0.635,0.375 10 false Sun Gear (MG2) 1.833,1.927 2.5,2.323 0.667,0.396 10 false Ring Gear (Output)* 0.646,2.771 2.01,3.104 1.365,0.333 10 false Power Split Planetary Gear Unit 0.135,0.198 1.698,0.448 1.563,0.25 12 false Nomographic Chart: 2.26,2.76 3.563,3.135 1.302,0.375 10 false Reduction Planetary Gear Unit 1.219,1.927 1.719,2.313 0.5,0.385 10 false Carrier (Engine) 2.563,1.917 3.042,2.313 0.479,0.396 10 false Carrier (Fixed)


iv.

For the hybrid system, motor generators have different roles depending on the situation. Understanding the relationship between the rotation direction and torque can help to make the role of a motor generator easier to understand.


v.

The table below shows the relationship of drive and electric generation for different combinations of plus or negative torque and forward or reverse rotation.

Rotation Direction Torque Condition Role of Component
Forward (+) Rotation Positive Torque Drive
Negative Torque Electric Generation
Reverse (-) Rotation Positive Torque Electric Generation
Negative Torque Drive


vi.

As an example, if a motor generator is rotating in the forward (+) direction, and it applies negative torque, it will generate electricity (producing electrical power).


vii.

Alternately, if the motor generator is rotating in the reverse (-) direction and it applies minus torque, it will act as a drive source (consuming electrical power).



c.

Driving Condition B: Starting Off

i.

When the vehicle is started off, the vehicle operates powered by MG2. If the required drive torque increases when running with MG2 only, MG1 is activated to start the engine.

HINT:

*: Refer to the preceding driving condition graph and table for more details.


W101657E21
2.479,1.125 2.708,1.323 0.229,0.198 10 false *1 1.521,1.677 1.802,1.875 0.281,0.198 10 false *2 3.281,1.813 3.5,2 0.219,0.188 10 false *3 2.479,2.469 2.76,2.667 0.281,0.198 10 false *4 2.479,1.729 2.688,1.917 0.208,0.188 10 false *5 2.479,1.917 2.688,2.104 0.208,0.188 10 true *6 3.469,2.469 3.75,2.667 0.281,0.198 10 false *7 4.542,2.469 4.823,2.667 0.281,0.198 10 false *8

Text in Illustration
*1 Engine (Stopped) *2 Hybrid Vehicle Transaxle Assembly
*3 MG1 (Rotates Freely) *4 MG2 (Drive)
*5 Power Split Planetary Gear Unit *6 Motor Speed Reduction Planetary Gear Unit
*7 Inverter with Converter Assembly *8 HV Battery
V100144

Mechanical Power Path
V100155

Electrical Power Path
V100135

Power Transmission - -


ii.

While the vehicle is running with the motive force of MG2 only, the rotational speed of the carrier (engine) is 0 rpm due to the engine being stopped. In addition, since MG1 does not generate any torque, no torque acts on the sun gear (MG1). However, the sun gear rotates freely in the (-) direction balancing the rotating ring gear.

W101154E19
2.281,1.271 2.281,1.01 2.281,1.01 1.979,1.01 true 3.656,0.594 3.656,0.354 3.656,0.354 3.427,0.354 true 2.729,1.573 2.729,2.031 true 4.823,1.583 4.823,2.042 true 4.208,0.594 4.208,0.354 4.208,0.354 4.427,0.354 true 1.073,5.302 2.26,5.583 1.188,0.281 10 false Sun Gear (MG1) 1.24,4.49 1.667,4.698 0.427,0.208 10 false 0 rpm 1.458,3.781 1.781,3.99 0.323,0.208 10 false (+) 2.604,3.781 2.927,3.99 0.323,0.208 10 false (+) 3.333,3.792 3.656,4 0.323,0.208 10 false (+) 5.146,5.083 5.375,5.292 0.229,0.208 10 false (+) 1.49,5.094 1.813,5.302 0.323,0.208 10 false (-) 2.656,5.104 2.896,5.313 0.24,0.208 10 false (-) 3.396,5.115 3.646,5.323 0.25,0.208 10 false (-) 5.167,3.792 5.427,4.031 0.26,0.24 10 false (-) 5.271,5.292 6.469,5.552 1.198,0.26 10 false Sun Gear (MG2) 0.813,0.885 1.948,1.135 1.135,0.25 10 false Engine (Stopped) 1.406,0.25 3.406,0.469 2,0.219 10 false Power Split Planetary Gear Unit 4.469,0.219 6.49,0.438 2.021,0.219 10 false Reduction Planetary Gear Unit 3.354,5.302 4.063,5.74 0.708,0.438 10 false Ring Gear (Output) 1.542,6.156 3.573,6.49 2.031,0.333 10 false Power Split Planetary Gear Unit 0.302,3.198 1.865,3.448 1.563,0.25 12 false Nomographic Chart: 0.302,0.156 1.156,0.417 0.854,0.26 12 false Geartrain: 3.708,6.146 5.802,6.375 2.094,0.229 10 false Reduction Planetary Gear Unit 2.563,5.302 3.073,5.688 0.51,0.385 10 false Carrier (Engine) 4.115,5.292 5.115,5.531 1,0.24 10 false Carrier (Fixed) 1.76,2.042 3.219,2.281 1.458,0.24 10 false MG1 (Rotates Freely) 4.51,2.042 5.385,2.292 0.875,0.25 10 false MG2 (Drive)



d.

Driving Condition C: Constant-speed Cruising

i.

When the vehicle is running under low load and constant-speed cruising, the motive force of the engine is transmitted by the power split planetary gear unit. Some of this motive force is output directly, and the remaining motive force is used for generating electricity through MG1. Through the use of the electrical power path of an inverter, this electrical power is transmitted to MG2 to be output as the motive force of MG2. If the SOC level of the HV battery is low, it is charged by MG1 driven by the engine.

HINT:

*: Refer to the preceding driving condition graph and table for more details.


W101661E21
2.458,1.135 2.74,1.333 0.281,0.198 10 false *1 1.521,1.677 1.708,1.854 0.188,0.177 10 false *2 3.271,1.802 3.469,1.969 0.198,0.167 10 false *3 2.479,2.479 2.76,2.677 0.281,0.198 10 false *4 3.469,2.479 3.75,2.677 0.281,0.198 10 false *7 4.521,2.458 4.729,2.646 0.208,0.188 10 false *8 2.469,1.719 2.656,1.896 0.188,0.177 10 true *5 2.469,1.917 2.656,2.094 0.188,0.177 10 true *6

Text in Illustration
*1 Engine (Drive) *2 Hybrid Vehicle Transaxle Assembly
*3 MG1 (Generates Electricity) *4 MG2 (Drive)
*5 Power Split Planetary Gear Unit *6 Motor Speed Reduction Planetary Gear Unit
*7 Inverter with Converter Assembly *8 HV Battery
V100144

Mechanical Power Path
V100155

Electrical Power Path
V100135

Power Transmission - -


ii.

The torque from the engine acts on the carrier in the (+) direction, causing the sun gear (MG1) to turn in the (+) direction due to the reaction of the negative torque. MG1 generates electricity by harnessing the negative torque that acts on the sun gear (MG1).

W104327E17
2.26,1.219 2.26,1 2.26,1 1.958,1 true 3.656,0.594 3.656,0.396 3.656,0.396 3.396,0.396 true 2.729,1.594 2.729,2.063 true 4.823,1.583 4.823,2.052 true 4.198,0.604 4.198,0.406 4.198,0.406 4.427,0.406 true 1.073,5.313 2.26,5.594 1.188,0.281 10 false Sun Gear (MG1) 1.208,4.49 1.656,4.719 0.448,0.229 10 false 0 rpm 1.469,3.781 1.792,3.99 0.323,0.208 10 false (+) 2.604,3.781 2.927,3.99 0.323,0.208 10 false (+) 3.344,3.781 3.667,3.99 0.323,0.208 10 false (+) 5.146,5.115 5.396,5.323 0.25,0.208 10 false (+) 1.49,5.125 1.813,5.333 0.323,0.208 10 false (-) 2.646,5.115 2.885,5.323 0.24,0.208 10 false (-) 3.396,5.115 3.646,5.323 0.25,0.208 10 false (-) 5.188,3.781 5.448,4.021 0.26,0.24 10 false (-) 5.271,5.323 6.406,5.563 1.135,0.24 10 false Sun Gear (MG2) 1,0.885 1.938,1.115 0.938,0.229 10 false Engine (Drive) 1.385,0.271 3.385,0.458 2,0.188 10 false Power Split Planetary Gear Unit 4.479,0.292 6.479,0.51 2,0.219 10 false Reduction Planetary Gear Unit 3.313,5.313 3.979,5.74 0.667,0.427 10 false Ring Gear (Output) 1.542,6.156 3.573,6.385 2.031,0.229 10 false Power Split Planetary Gear Unit 0.302,3.24 1.865,3.49 1.563,0.25 12 false Nomographic Chart: 0.438,0.125 1.292,0.385 0.854,0.26 12 false Geartrain: 3.708,6.146 5.802,6.375 2.094,0.229 10 false Reduction Planetary Gear Unit 2.563,5.313 3.094,5.719 0.531,0.406 10 false Carrier (Engine) 4.115,5.323 5.115,5.531 1,0.208 10 false Carrier (Fixed) 1.354,2.073 3.146,2.323 1.792,0.25 10 false MG1 (Generates Electricity) 4.635,2.063 5.479,2.313 0.844,0.25 10 false MG2 (Drive)



e.

Driving Condition D: During Full Throttle Acceleration

i.

When the vehicle driving condition changes from low load cruising to full-throttle acceleration, the system supplements the motive force of MG2 with electrical power from the HV battery.

HINT:

*: Refer to the preceding driving condition graph and table for more details.


W101663E22
2.479,1.125 2.688,1.323 0.208,0.198 10 false *1 1.521,1.698 1.729,1.896 0.208,0.198 10 false *2 3.281,1.823 3.49,2.021 0.208,0.198 10 false *3 2.479,2.469 2.76,2.667 0.281,0.198 10 false *4 3.469,2.479 3.75,2.677 0.281,0.198 10 false *7 4.542,2.469 4.823,2.667 0.281,0.198 10 false *8 2.479,1.719 2.688,1.906 0.208,0.188 10 true *5 2.479,1.927 2.688,2.115 0.208,0.188 10 true *6

Text in Illustration
*1 Engine (Drive) *2 Hybrid Vehicle Transaxle Assembly
*3 MG1 (Generates Electricity) *4 MG2 (Drive)
*5 Power Split Planetary Gear Unit *6 Motor Speed Reduction Planetary Gear Unit
*7 Inverter with Converter Assembly *8 HV Battery
V100144

Mechanical Power Path
V100155

Electrical Power Path
V100135

Power Transmission - -


ii.

When more engine power is required, in order to increase the engine speed, the rotational speeds of the related gears change as follows. The torque from the engine acts on the carrier in the (+) direction, causing the sun gear (MG1) to turn in the (+) direction due to the reaction of the negative torque. MG1 generates electricity by harnessing the negative torque that acts on the sun gear (MG1).

W101160E20
2.25,1.188 2.25,0.969 2.25,0.969 1.948,0.969 true 3.667,0.594 3.667,0.417 3.667,0.417 3.375,0.417 true 2.708,1.604 2.708,2.073 true 4.813,1.594 4.813,2.063 true 4.208,0.594 4.208,0.406 4.208,0.406 4.438,0.406 true 1.146,5.354 2.24,5.583 1.094,0.229 10 false Sun Gear (MG1) 1.208,4.5 1.625,4.708 0.417,0.208 10 false 0 rpm 1.448,3.781 1.771,3.99 0.323,0.208 10 false (+) 2.594,3.781 2.833,3.99 0.24,0.208 10 false (+) 3.333,3.781 3.583,3.99 0.25,0.208 10 false (+) 5.135,5.115 5.385,5.323 0.25,0.208 10 false (+) 1.479,5.125 1.698,5.313 0.219,0.188 10 false (-) 2.625,5.125 2.833,5.333 0.208,0.208 10 false (-) 3.385,5.125 3.635,5.333 0.25,0.208 10 false (-) 5.167,3.781 5.427,4.021 0.26,0.24 10 false (-) 5.104,5.333 6.219,5.563 1.115,0.229 10 false Sun Gear (MG2) 1.01,0.833 1.948,1.083 0.938,0.25 10 false Engine (Drive) 1.375,0.292 3.365,0.51 1.99,0.219 10 false Power Split Planetary Gear Unit 4.49,0.313 6.51,0.531 2.021,0.219 10 false Reduction Planetary Gear Unit 3.292,5.333 3.958,5.74 0.667,0.406 10 false Ring Gear (Output) 1.51,6.135 3.542,6.469 2.031,0.333 10 false Power Split Planetary Gear Unit 0.271,3.344 1.833,3.594 1.563,0.25 12 false Nomographic Chart: 0.281,0.156 1.135,0.417 0.854,0.26 12 false Geartrain: 3.677,6.125 5.771,6.354 2.094,0.229 10 false Reduction Planetary Gear Unit 2.573,5.344 3.125,5.75 0.552,0.406 10 false Carrier (Engine) 4.031,5.333 4.969,5.563 0.938,0.229 10 false Carrier (Fixed) 1.448,2.083 3.344,2.323 1.896,0.24 10 false MG1 (Generates Electricity) 4.594,2.073 5.438,2.323 0.844,0.25 10 false MG2 (Drive)



f.

Driving Condition E: During Deceleration

i.

While the vehicle decelerates with drive (D) selected, the engine is turned off and the motive force changes to zero. At this time, the wheels drive MG2, causing MG2 to operate as a generator, charging the HV battery. If the vehicle decelerates from a higher speed, the engine maintains a predetermined speed without stopping, in order to protect the planetary gears.

HINT:

*: Refer to the preceding driving condition graph and table for more details.


W101665E21
2.458,1.125 2.74,1.323 0.281,0.198 10 false *1 1.521,1.708 1.802,1.906 0.281,0.198 10 false *2 3.25,1.802 3.531,2 0.281,0.198 10 false *3 2.479,2.479 2.76,2.677 0.281,0.198 10 false *4 3.469,2.469 3.75,2.667 0.281,0.198 10 false *7 4.51,2.458 4.729,2.646 0.219,0.188 10 false *8 2.479,1.729 2.667,1.896 0.188,0.167 10 false *5 2.479,1.927 2.667,2.094 0.188,0.167 10 true *6

Text in Illustration
*1 Engine (Stopped) *2 Hybrid Vehicle Transaxle Assembly
*3 MG1 (Rotates Freely) *4 MG2 (Generates Electricity)
*5 Power Split Planetary Gear Unit *6 Motor Speed Reduction Planetary Gear Unit
*7 Inverter with Converter Assembly *8 HV Battery
V100144

Mechanical Power Path
V100155

Electrical Power Path
V100135

Power Transmission - -


ii.

During deceleration, the ring gear is rotated by the wheels. Under this condition, due to the engine being stopped, the rotational speed of the carrier (engine) is 0 rpm. In addition, since MG1 does not generate any torque, no torque acts on the sun gear (MG1). However, the sun gear (MG1) rotates freely in the (-) direction, balancing the rotating ring gear.

W101162E19
2.26,1.26 2.26,1.042 2.26,1.042 1.948,1.042 true 3.667,0.594 3.667,0.396 3.667,0.396 3.385,0.396 true 2.729,1.552 2.729,2.021 true 4.813,1.573 4.813,2.01 true 4.198,0.594 4.198,0.396 4.198,0.396 4.427,0.396 true 1.063,5.333 2.25,5.615 1.188,0.281 10 false Sun Gear (MG1) 1.229,4.49 1.625,4.698 0.396,0.208 10 false 0 rpm 1.458,3.771 1.781,3.979 0.323,0.208 10 false (+) 2.594,3.781 2.917,3.99 0.323,0.208 10 false (+) 3.344,3.781 3.667,3.99 0.323,0.208 10 false (+) 5.156,5.115 5.406,5.323 0.25,0.208 10 false (+) 1.458,5.115 1.781,5.323 0.323,0.208 10 false (-) 2.625,5.115 2.865,5.323 0.24,0.208 10 false (-) 3.385,5.115 3.635,5.323 0.25,0.208 10 false (-) 5.188,3.771 5.448,4.01 0.26,0.24 10 false (-) 5.156,5.333 6.354,5.594 1.198,0.26 10 false Sun Gear (MG2) 0.813,0.927 1.948,1.156 1.135,0.229 10 false Engine (Stopped) 1.375,0.281 3.365,0.469 1.99,0.188 10 false Power Split Planetary Gear Unit 4.49,0.271 6.51,0.49 2.021,0.219 10 false Reduction Planetary Gear Unit 3.333,5.333 4,5.708 0.667,0.375 10 false Ring Gear (Output) 1.521,6.156 3.552,6.396 2.031,0.24 10 false Power Split Planetary Gear Unit 0.281,3.292 1.844,3.542 1.563,0.25 12 false Nomographic Chart: 0.427,0.115 1.281,0.375 0.854,0.26 12 false Geartrain: 3.688,6.146 5.667,6.344 1.979,0.198 10 false Reduction Planetary Gear Unit 2.604,5.333 3.135,5.75 0.531,0.417 10 false Carrier (Engine) 4.115,5.333 5.115,5.573 1,0.24 10 false Carrier (Fixed) 1.771,2.031 3.24,2.302 1.469,0.271 10 false MG1 (Rotates Freely) 4.635,2.01 6.573,2.26 1.938,0.25 10 false MG2 (Generates Electricity)



g.

Driving Condition F: During Reverse

i.

When the vehicle is being driven in reverse, the required power is supplied by MG2. At this time, MG2 rotates in the opposite direction, the engine remains stopped, and MG1 rotates in the normal direction without generating electricity.

HINT:

*: Refer to the preceding driving condition graph and table for more details.


W101667E19
2.448,1.125 2.729,1.323 0.281,0.198 10 false *1 1.521,1.698 1.729,1.885 0.208,0.188 10 false *2 3.281,1.771 3.5,1.948 0.219,0.177 10 false *3 2.479,2.469 2.76,2.667 0.281,0.198 10 false *4 2.479,1.729 2.667,1.885 0.188,0.156 10 false *5 2.479,1.917 2.667,2.083 0.188,0.167 10 true *6 3.469,2.469 3.75,2.667 0.281,0.198 10 false *7 4.51,2.448 4.792,2.646 0.281,0.198 10 false *8

Text in Illustration
*1 Engine (Stopped) *2 Hybrid Vehicle Transaxle Assembly
*3 MG1 (Rotates Freely) *4 MG2 (Drive)
*5 Power Split Planetary Gear Unit *6 Motor Speed Reduction Planetary Gear Unit
*7 Inverter with Converter Assembly *8 HV Battery
V100144

Mechanical Power Path
V100155

Electrical Power Path
V100135

Power Transmission - -


ii.

The conditions of the planetary gear are opposite to those described in "Starting Off". Due to the engine being stopped, the rotational speed of the carrier (engine) is 0 rpm but the sun gear (MG1) rotates freely in the (+) direction, balancing the rotating ring gear.

W101165E13
2.25,1.25 2.25,1.031 2.25,1.031 1.938,1.031 true 3.656,0.615 3.656,0.427 3.656,0.427 3.344,0.427 true 2.719,1.583 2.719,2.052 true 4.813,1.583 4.813,2.052 true 4.198,0.615 4.198,0.427 4.198,0.427 4.417,0.427 true 1.125,5.292 2.219,5.542 1.094,0.25 10 false Sun Gear (MG1) 1.25,4.51 1.677,4.719 0.427,0.208 10 false 0 rpm 1.479,3.781 1.802,3.99 0.323,0.208 10 false (+) 2.604,3.781 2.927,3.99 0.323,0.208 10 false (+) 3.344,3.771 3.667,3.979 0.323,0.208 10 false (+) 5.146,5.104 5.396,5.313 0.25,0.208 10 false (+) 1.521,5.104 1.74,5.323 0.219,0.219 10 false (-) 2.646,5.094 2.885,5.302 0.24,0.208 10 false (-) 3.396,5.083 3.583,5.292 0.188,0.208 10 false (-) 5.177,3.771 5.438,4.01 0.26,0.24 10 false (-) 5.073,5.302 6.271,5.563 1.198,0.26 10 false Sun Gear (MG2) 0.813,0.917 1.948,1.135 1.135,0.219 10 false Engine (Stopped) 1.344,0.323 3.333,0.531 1.99,0.208 10 false Power Split Planetary Gear Unit 4.49,0.313 6.51,0.531 2.021,0.219 10 false Reduction Planetary Gear Unit 3.281,5.271 3.938,5.708 0.656,0.438 10 false Ring Gear (Output) 1.573,6.135 3.604,6.469 2.031,0.333 10 false Power Split Planetary Gear Unit 0.302,3.302 1.865,3.552 1.563,0.25 12 false Nomographic Chart: 0.281,0.115 1.135,0.375 0.854,0.26 12 false Geartrain: 3.625,6.146 5.719,6.375 2.094,0.229 10 false Reduction Planetary Gear Unit 2.552,5.26 3.083,5.698 0.531,0.438 10 false Carrier (Engine) 4.021,5.281 5.021,5.521 1,0.24 10 false Carrier (Fixed) 1.792,2.052 3.188,2.292 1.396,0.24 10 false MG1 (Rotates Freely) 4.5,2.073 5.323,2.302 0.823,0.229 10 false MG2 (Drive)




DIAGNOSIS


a.

When the power management control ECU detects a malfunction in the hybrid system, the power management control ECU performs diagnosis and memorizes information related to the fault. To inform the driver of the malfunction, the power management control ECU illuminates or blinks the Malfunction Indicator Lamp (MIL) and hybrid system warning light. At the same time, a Diagnostic Trouble Code (DTC) is stored in memory.


b.

3-digit information codes (INF codes) are provided with the conventional DTC as subset of the primary 5-digit code. This enables the troubleshooting procedure to further narrow down a trouble area to identify a problem.


c.

The DTC can be read by connecting the Global TechStream (GTS) to the DLC3. For details, refer to the Repair Manual.