Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › from 2020.08
NM2070E _58 Vehicle Interior _061892 HEATING / AIR CONDITIONING _0301438 AIR CONDITIONING SYSTEM UN GENERAL/CONTROL/DETAILS F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  GENERAL/CONTROL/DETAILS  GENERAL  


OUTLINE


a.

The air conditioning system main components have been made compact, lightweight, and highly efficient to realize a combination of ensuring comfort and enhancing actual fuel consumption.



SPECIFICATION


a.

Performance

Heater Heater Output W 5200
Air Flow Volume m3/h 330
Power Consumption W 205
Cooler Cooling Capacity W 4920
Air Flow Volume m3/h 475
Power Consumption W 250


b.

Ventilation and Heater Radiator Unit Sub-assembly

Heater Radiator Unit Sub-assembly Type Straight Flow Aluminum (SFA)-II
Size
W x H x L
mm (in.) 201.5 x 150 x 27
(7.9 x 5.9 x 1.1)
Fin Pitch mm (in.) 1.8 (0.07)
Blower with Fan Motor Sub-assembly Motor Type K70-10.5T
Fan Type Semi Sirocco
Fan Size (Dia. x H) mm (in.) 155 x 65 (6.1 x 2.6)


c.

Air Conditioning

Condenser with Receiver Assembly Type Multi-flow IV
(Sub Cool)
Size
W x H x L
mm (in.) 636 x 280.6 x 22
(25 x 11.0 x 0.9)
Fin Pitch mm (in.) 2.7 (0.11)
Cooler Evaporator Sub-assembly No. 1 Type Ejector Cycle System (ECS)
Size
W x H x L
mm (in.) 226.1 x 241 x 38
(8.9 x 9.5 x 1.5)
Fin Pitch mm (in.) 3.0 (0.12)
Compressor with Motor Assembly Type ES27
Compressor Oil Type ND11
Refrigerant Type HFC-134a
Charge Volume g (oz) 440 to 500 (15.6 to 17.6)
Clean Air Filter Pollen Removal Type



MAIN FEATURES


a.

The air conditioning system has the following features:

High Performance
·

Neural network control is used so passengers can control the air conditioning accurately for maximum comfort.

·

A pollen removal type clean air filter is used as the clean air filter (air refiner element).

·

Micro dust pollen filter mode control is used to remove pollen in the area around the upper part of the bodies of the driver and front passenger.

·

The blower control has 7 levels in manual mode and 31 levels in AUTO mode for more precise control.

·

An ejector cycle system is used in the refrigerant cycle, increasing energy consumption efficiency and cooling performance.


Lightweight A bus connector with a built-in communication/driver IC is used in the air conditioning harness assembly to create a lightweight wire harness design with a reduced number of wires. The use of this type of connector means that pulse pattern type servo motors are used.
Compact
·

A semi-center location air conditioning radiator assembly is used, in which the cooler evaporator sub-assembly No. 1 and heater radiator unit sub-assembly are mounted horizontally.

·

A blower motor with a built-in blower motor controller is used to create a compact construction.

·

An ejector is placed in the cooler evaporator sub-assembly No. 1, thus allowing the ejector cycle to operate in a space equivalent to that of a conventional evaporator.


Others

The following parts are used to ensure high performance while realizing a compact and lightweight construction.

-

ES27 type compressor with motor assembly

-

Ejector Cycle System (ECS) type cooler evaporator sub-assembly

-

Straight Flow Aluminum (SFA)-II type heater radiator unit sub-assembly

-

Multi-flow (MF)-IV type condenser with receiver assembly