OUTLINE
The air conditioning system main components have been made compact, lightweight, and highly efficient to realize a combination of ensuring comfort and enhancing actual fuel consumption.
SPECIFICATION
Performance
| Heater | Heater Output | W | 5200 |
| Air Flow Volume | m3/h | 330 | |
| Power Consumption | W | 205 | |
| Cooler | Cooling Capacity | W | 4920 |
| Air Flow Volume | m3/h | 475 | |
| Power Consumption | W | 250 |
Ventilation and Heater Radiator Unit Sub-assembly
| Heater Radiator Unit Sub-assembly | Type | Straight Flow Aluminum (SFA)-II | |
| Size
W x H x L |
mm (in.) | 201.5 x 150 x 27
(7.9 x 5.9 x 1.1) |
|
| Fin Pitch | mm (in.) | 1.8 (0.07) | |
| Blower with Fan Motor Sub-assembly | Motor Type | K70-10.5T | |
| Fan Type | Semi Sirocco | ||
| Fan Size (Dia. x H) | mm (in.) | 155 x 65 (6.1 x 2.6) | |
Air Conditioning
| Condenser with Receiver Assembly | Type | Multi-flow IV
(Sub Cool) |
|
| Size
W x H x L |
mm (in.) | 636 x 280.6 x 22
(25 x 11.0 x 0.9) |
|
| Fin Pitch | mm (in.) | 2.7 (0.11) | |
| Cooler Evaporator Sub-assembly No. 1 | Type | Ejector Cycle System (ECS) | |
| Size
W x H x L |
mm (in.) | 226.1 x 241 x 38
(8.9 x 9.5 x 1.5) |
|
| Fin Pitch | mm (in.) | 3.0 (0.12) | |
| Compressor with Motor Assembly | Type | ES27 | |
| Compressor Oil Type | ND11 | ||
| Refrigerant | Type | HFC-134a | |
| Charge Volume | g (oz) | 440 to 500 (15.6 to 17.6) | |
| Clean Air Filter | Pollen Removal Type | ||
MAIN FEATURES
The air conditioning system has the following features:
| High Performance | ·
Neural network control is used so passengers can control the air conditioning accurately for maximum comfort. ·
A pollen removal type clean air filter is used as the clean air filter (air refiner element). ·
Micro dust pollen filter mode control is used to remove pollen in the area around the upper part of the bodies of the driver and front passenger. ·
The blower control has 7 levels in manual mode and 31 levels in AUTO mode for more precise control. ·
An ejector cycle system is used in the refrigerant cycle, increasing energy consumption efficiency and cooling performance. |
| Lightweight | A bus connector with a built-in communication/driver IC is used in the air conditioning harness assembly to create a lightweight wire harness design with a reduced number of wires. The use of this type of connector means that pulse pattern type servo motors are used. |
| Compact | ·
A semi-center location air conditioning radiator assembly is used, in which the cooler evaporator sub-assembly No. 1 and heater radiator unit sub-assembly are mounted horizontally. ·
A blower motor with a built-in blower motor controller is used to create a compact construction. ·
An ejector is placed in the cooler evaporator sub-assembly No. 1, thus allowing the ejector cycle to operate in a space equivalent to that of a conventional evaporator. |
| Others | The following parts are used to ensure high performance while realizing a compact and lightweight construction. -
ES27 type compressor with motor assembly -
Ejector Cycle System (ECS) type cooler evaporator sub-assembly -
Straight Flow Aluminum (SFA)-II type heater radiator unit sub-assembly -
Multi-flow (MF)-IV type condenser with receiver assembly |