Home › General › SPECIFICATIONS › HYBRID / BATTERY CONTROL
RM2070E _V1 General _061903 SPECIFICATIONS _0301506 HYBRID / BATTERY CONTROL F

SPECIFICATIONS  HYBRID / BATTERY CONTROL  SERVICE DATA  


Reserve Tank Cap (for Inverter)
Item Specified Condition
Standard value (for brand-new cap) 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi)
Minimum standard value (for used cap) 94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay
Item Tester Connection Specified Condition
IGCT relay
Resistance
3 - 5 10 kΩ or higher
(No auxiliary battery voltage is applied across terminals 1 and 2)
3 - 5 Below 1 Ω
(Auxiliary battery voltage is applied across terminals 1 and 2)

Hybrid Battery Junction Block assembly
SMRB
Resistance
k3-1 (+) - T6-1 (CBI)) 10 kΩ or higher
(Auxiliary battery voltage is not applied between terminals c6-4 (SMRB) and c6-2 (GND))
Below 1 Ω
(Auxiliary battery voltage is applied between terminals c6-4 (SMRB) and c6-2 (GND))
c6-4 (SMRB) - c6-2 (GND) 19.0 to 35.5 Ω (at -40 to 80°C (-40 to 176°F))
SMRG
Resistance
h3-1 (-) - T5-1 (CEI) 10 kΩ or higher
(Auxiliary battery voltage is not applied between terminals c6-1 (SMRG) and c6-2 (GND))
Below 1 Ω
(Auxiliary battery voltage is applied between terminals c6-1 (SMRG) and c6-2 (GND))
c6-1 (SMRG) - c6-2 (GND) 19.0 to 35.5 Ω (at -40 to 80°C (-40 to 176°F))
SMRP
Resistance
h3-1 (-) - T5-1 (CEI) 10 kΩ or higher
(Auxiliary battery voltage is not applied between terminals c6-3 (SMRP) and c6-2 (GND))
28.5 to 31.5 Ω
(Auxiliary battery voltage is applied between terminals c6-3 (SMRP) and c6-2 (GND))
c6-3 (SMRP) - c6-2 (GND) 112 to 274 Ω (at -40 to 80°C (-40 to 176°F))

Service plug grip
Service plug grip Always Below 1 Ω

Combination switch assembly
EV drive mode switch (combination switch assembly) 7 (S) - 3 (E) Below 1 Ω
(EV drive mode switch (combination switch assembly) being pushed and held)
10 kΩ or higher
(EV drive mode switch (combination switch assembly) not pushed)
POWER mode switch (combination switch assembly) 8 (PWR) - 3 (E) Below 1 Ω
(POWER mode switch (combination switch assembly) being pushed and held)
10 kΩ or higher
(POWER mode switch (combination switch assembly) not pushed)
ECO mode switch (combination switch assembly) 5 (ECU) - 3 (E) Below 1 Ω
(ECO mode switch (combination switch assembly) being pushed and held)
10 kΩ or higher
(ECO mode switch (combination switch assembly) not pushed)
Illumination Auxiliary battery positive (+) →Terminal 6 (ILL+)
Auxiliary battery negative (-) →Terminal 1 (ILL-)
Illuminates