Home › Engine / Hybrid System › 2ZR-FXE (ENGINE CONTROL) › INTEGRATION RELAY
RM2070E _51 Engine / Hybrid System _061905 2ZR-FXE ENGINE CONTROL _0301572 INTEGRATION RELAY G

2ZR-FXE ENGINE CONTROL  INTEGRATION RELAY  INSPECTION  


PROCEDURE

Hide 82641C 1.INSPECT NO. 2 INTEGRATION RELAY

A260019E01
1.449,1.299 1.581,1.501 0.132,0.202 10 1 1.637,0.94 1.849,1.100 0.212,0.160 10 1C 3.188,0.395 3.462,0.662 0.274,0.267 10 IG2 3.025,2.519 3.654,2.802 0.629,0.283 10 EFI MAIN 2.979,1.427 3.680,1.751 0.701,0.324 10 BATT FAN 3.914,1.832 4.609,2.156 0.695,0.324 10 BATT FAN 3.931,2.902 4.591,3.237 0.661,0.335 10 EFI MAIN 4.017,4.209 4.478,4.517 0.462,0.309 10 C/OPN 4.134,0.771 4.407,1.038 0.274,0.267 10 IG2 6.549,0.08 6.770,0.321 0.222,0.241 10 1A 6.56,2.363 6.759,2.598 0.199,0.235 10 1B 6.05,0.227 6.233,0.383 0.183,0.157 10 4 6.05,0.499 6.229,0.678 0.179,0.179 10 3 6.05,0.985 6.205,1.140 0.155,0.155 10 2 6.05,1.266 6.233,1.423 0.183,0.157 10 8 6.05,1.566 6.229,1.745 0.179,0.179 10 7 6.05,2.053 6.205,2.208 0.155,0.155 10 6 6.05,2.358 6.219,2.513 0.169,0.156 10 4 6.05,2.623 6.203,2.776 0.153,0.153 10 3 6.05,3.14 6.210,3.300 0.160,0.160 10 2 6.05,3.384 6.210,3.543 0.160,0.160 10 5 6.05,3.641 6.210,3.801 0.160,0.160 10 8 6.05,3.927 6.210,4.087 0.160,0.160 10 7 6.05,4.422 6.210,4.582 0.160,0.160 10 6 0.143,0.165 0.331,0.501 0.188,0.336 10 *1

Text in Illustration
*1 No. 2 Integration Relay - -

a.

IG2 RELAY:

i.
A379249E01
0.094,0.104 0.406,0.302 0.313,0.198 10 false *1 0.438,0.708 0.75,0.906 0.313,0.198 10 false 1C 1.26,0.719 1.573,0.917 0.313,0.198 10 false 1B 2.406,0.708 2.719,0.906 0.313,0.198 10 false 1A

Measure the resistance according to the value(s) in the table below.

Text in Illustration
*1 No. 2 Integration Relay

Standard Resistance:
Tester Connection Condition Specified Condition
No. 2 Integration Relay (1C-1) - No. 2 Integration Relay (1A-4) Auxiliary battery voltage is not applied between terminals 1A-3 and 1A-2 10 kΩ or higher
No. 2 Integration Relay (1C-1) - No. 2 Integration Relay (1A-4) Auxiliary battery voltage is applied between terminals 1A-3 and 1A-2 Below 1 Ω


If the resistance is not as specified, replace the No. 2 integration relay.



b.

BATT FAN RELAY:

i.
A379249E01
0.094,0.104 0.406,0.302 0.313,0.198 10 false *1 0.438,0.708 0.75,0.906 0.313,0.198 10 false 1C 1.26,0.719 1.573,0.917 0.313,0.198 10 false 1B 2.406,0.708 2.719,0.906 0.313,0.198 10 false 1A

Measure the resistance according to the value(s) in the table below.

Text in Illustration
*1 No. 2 Integration Relay

Standard Resistance:
Tester Connection Condition Specified Condition
No. 2 Integration Relay (1C-1) - No. 2 Integration Relay (1A-8) Auxiliary battery voltage is not applied between terminals 1A-7 and 1A-6 10 kΩ or higher
No. 2 Integration Relay (1C-1) - No. 2 Integration Relay (1A-8) Auxiliary battery voltage is applied between terminals 1A-7 and 1A-6 Below 1 Ω


If the resistance is not as specified, replace the No. 2 integration relay.



c.

EFI MAIN RELAY:

i.
A379249E01
0.094,0.104 0.406,0.302 0.313,0.198 10 false *1 0.438,0.708 0.75,0.906 0.313,0.198 10 false 1C 1.26,0.719 1.573,0.917 0.313,0.198 10 false 1B 2.406,0.708 2.719,0.906 0.313,0.198 10 false 1A

Measure the resistance according to the value(s) in the table below.

Text in Illustration
*1 No. 2 Integration Relay

Standard Resistance:
Tester Connection Condition Specified Condition
No. 2 Integration Relay (1C-1) - No. 2 Integration Relay (1B-4) Auxiliary battery voltage is not applied between terminals 1B-2 and 1B-3 10 kΩ or higher
No. 2 Integration Relay (1C-1) - No. 2 Integration Relay (1B-4) Auxiliary battery voltage is applied between terminals 1B-2 and 1B-3 Below 1 Ω


If the resistance is not as specified, replace the No. 2 integration relay.



d.

C/OPN RELAY:

i.
A379249E01
0.094,0.104 0.406,0.302 0.313,0.198 10 false *1 0.438,0.708 0.75,0.906 0.313,0.198 10 false 1C 1.26,0.719 1.573,0.917 0.313,0.198 10 false 1B 2.406,0.708 2.719,0.906 0.313,0.198 10 false 1A

Measure the resistance according to the value(s) in the table below.

Text in Illustration
*1 Integration Relay

Standard Resistance:
Tester Connection Condition Specified Condition
No. 2 Integration Relay (1B-5) - No. 2 Integration Relay (1B-8) Auxiliary battery voltage is not applied between terminals 1B-6 and 1B-7 10 kΩ or higher
No. 2 Integration Relay (1B-5) - No. 2 Integration Relay (1B-8) Auxiliary battery voltage is applied between terminals 1B-6 and 1B-7 Below 1 Ω


If the resistance is not as specified, replace the No. 2 integration relay.