Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2016.05
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM U

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  TERMINALS OF ECU  


U154686E03
0.208,0.073 0.708,0.281 0.5,0.208 10 false *a 1.438,1.458 1.76,1.625 0.323,0.167 10 false A21 2.833,1.458 3.156,1.625 0.323,0.167 10 false A22 4.313,1.458 4.531,1.625 0.219,0.167 10 false L5 5.583,1.458 5.823,1.625 0.24,0.167 10 false L6

Text in Illustration
*a Component without harness connected
(Hybrid Vehicle Control ECU)
- -

Hybrid vehicle control ECU
Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Specified Condition
A21-1 (+B2) - L5-6 (E1) L - W-B Power source Power switch on (IG) 11 to 14 V
A21-3 (IG2) - L5-6 (E1) R - W-B Power source Power switch on (IG) 11 to 14 V
A21-8 (VCP2) - A21-18 (EP2) G - R Accelerator pedal sensor assembly power source (for VPA2) Power switch on (IG) 4.5 to 5.5 V
A21-9 (VCP1) - A21-20 (EP1) Y - B Accelerator pedal sensor assembly power source (for VPA1) Power switch on (IG) 4.5 to 5.5 V
A21-10 (GI) - L5-6 (E1) Y - W-B Camshaft position sensor signal Power switch on (READY), with engine running Pulse generation
(Waveform 1)
A21-11 (FCTL) - L5-5 (E01) BR - W-B Cooling fan relay signal Power switch on (IG) Below 2 V
A21-13 (IWP) - L5-6 (E1) G - W-B Inverter water pump assembly signal Power switch on (READY) Pulse generation
(Waveform 2)
A21-14 (NIWP) - L5-6 (E1) P - W-B Inverter water pump assembly signal Power switch on (READY) Pulse generation
(Waveform 2)
A21-15 (STP) - L5-6 (E1) L*1 - W-B
G*2 - W-B
Stop light switch Brake pedal depressed 11 to 14 V
A21-15 (STP) - L5-6 (E1) L*1 - W-B
G*2 - W-B
Stop light switch Brake pedal released 0 to 1.5 V
A21-16 (VLO) - L5-6 (E1) R - W-B DC/DC operation monitor / voltage change signal Power switch on (IG) Pulse generation
(Waveform 3)
A21-24 (MMT) - A21-23 (MMTG) L - BR Motor temperature sensor Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
A21-24 (MMT) - A21-23 (MMTG) L - BR Motor temperature sensor Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A21-25 (NODD) - L5-6 (E1) W - W-B DC/DC operation DC/DC converter operating normally 5 to 7 V
A21-25 (NODD) - L5-6 (E1) W - W-B DC/DC operation DC/DC converter not operating normally 2 to 4 V
A21-25 (NODD) - L5-6 (E1) W - W-B DC/DC operation DC/DC converter operating prohibited 0.1 to 0.5 V
A21-26 (GMT) - A21-27 (GMTG) B - R Generator temperature sensor Power switch on (IG), temperature 25°C (77°F) 3.6 to 4.6 V
A21-26 (GMT) - A21-27 (GMTG) B - R Generator temperature sensor Power switch on (IG), temperature 60°C (140°F) 2.2 to 3.2 V
A21-28 (VPA2) - A21-18 (EP2) W - R Accelerator pedal sensor assembly (for accelerator pedal position detection) Power switch on (IG), accelerator pedal released 1.0 to 2.2 V
A21-28 (VPA2) - A21-18 (EP2) W - R Accelerator pedal sensor assembly (for accelerator pedal position detection) Power switch on (IG) engine stopped, park (P) selected, accelerator pedal fully depressed 3.4 to 5.3 V
A21-30 (VPA1) - A21-20 (EP1) L - B Accelerator pedal sensor assembly (for accelerator pedal position detection) Power switch on (IG), accelerator pedal released 0.4 to 1.4 V
A21-30 (VPA1) - A21-20 (EP1) L - B Accelerator pedal sensor assembly (for accelerator pedal position detection) Power switch on (IG) engine stopped, park (P) selected, accelerator pedal fully depressed 2.6 to 4.5 V
A22-2 (BL) - L5-6 (E1) R - W-B Back up light Power switch on (IG), shift lever in R 11 to 14 V
A22-4 (+B1) - L5-6 (E1) L - W-B Power source Power switch on (IG) 11 to 14 V
A22-6 (MREL) - L5-6 (E1) BE - W-B Main relay Power switch on (IG) 11 to 14 V
A22-8 (ETI) - L5-6 (E1) R - W-B A/C communication signal Power switch on (READY), air conditioning system stopped Pulse generation
(Waveform 4)
A22-9 (ITE) - L5-6 (E1) Y - W-B A/C communication signal Power switch on (READY), air conditioning system stopped Pulse generation
(Waveform 4)
A22-10 (CLK) - L5-6 (E1) G - W-B A/C communication signal Power switch on (READY), air conditioning system stopped Pulse generation
(Waveform 4)
A22-11 (STB) - L5-6 (E1) W - W-B A/C communication signal Power switch on (READY), air conditioning system stopped Pulse generation
(Waveform 4)
A22-12 (HSDN) - L5-6 (E1) B - W-B MG ECU shutdown signal Power switch on (READY) 0 to 1.5 V
A22-13 (ILK) - L5-6 (E1) V - W-B Interlock switch Power switch on (IG), inverter cover, high-voltage input cables and service plug grip installed correctly 0 to 1.5 V
A22-13 (ILK) - L5-6 (E1) V - W-B Interlock switch Power switch on (IG), inverter cover, high-voltage input cables or service plug grip not installed 11 to 14 V
A22-22 (MTH-) - L5-6 (E1) W - W-B Communication signal from MG ECU to hybrid vehicle control ECU Power switch on (IG) Pulse generation
(Waveform 5)
A22-23 (MTH+) - L5-6 (E1) B - W-B Communication signal from MG ECU to hybrid vehicle control ECU Power switch on (IG) Pulse generation
(Waveform 5)
A22-24 (HTM+) - L5-6 (E1) B - W-B Communication signal from hybrid vehicle control ECU to MG ECU Power switch on (IG) Pulse generation
(Waveform 6)
A22-25 (HTM-) - L5-6 (E1) W - W-B Communication signal from hybrid vehicle control ECU to MG ECU Power switch on (IG) Pulse generation
(Waveform 6)
A22-28 (ST1-) - L5-6 (E1) R - W-B Brake cancel switch Power switch on (IG), brake pedal depressed 0 to 1.5 V
A22-28 (ST1-) - L5-6 (E1) R - W-B Brake cancel switch Power switch on (IG), brake pedal released 11 to 14 V
A22-30 (REQ-) - L5-6 (E1) W - W-B MG ECU communication request signal Power switch on (IG) Pulse generation
(Waveform 7)
A22-31 (REQ+) - L5-6 (E1) B - W-B MG ECU communication request signal Power switch on (IG) Pulse generation
(Waveform 7)
A22-32 (CLK-) - L5-6 (E1) W - W-B MG communication clock signal Power switch on (IG) Pulse generation
(Waveform 8)
A22-33 (CLK+) - L5-6 (E1) B - W-B MG communication clock signal Power switch on (IG) Pulse generation
(Waveform 8)
L5-1 (SMRG) - L5-5 (E01) L - W-B System main relay operation signal Power switch on (IG)→Power switch on (READY) Pulse generation
(Waveform 9)
L5-3 (SMRP) - L5-5 (E01) LG - W-B System main relay operation signal Power switch on (IG)→Power switch on (READY) Pulse generation
(Waveform 9)
L5-4 (SMRB) - L5-5 (E01) SB - W-B System main relay operation signal Power switch on (IG)→Power switch on (READY) Pulse generation
(Waveform 9)
L5-8 (PCON) - L5-6 (E1) LG - W-B P position switch signal Power switch on (IG) Pulse generation
(Waveform 10)
L5-9 (ST2) - L5-6 (E1) G - W-B Starter signal Power switch on (IG) 0 to 1.5 V
L5-15 (PPOS) - L5-6 (E1) W - W-B P position switch signal Power switch on (IG) Pulse generation
(Waveform 10)
L5-16 (P1) - L5-6 (E1) Y - W-B P position switch signal Power switch on (IG), P position switch off 7 to 12 V
L5-16 (P1) - L5-6 (E1) Y - W-B P position switch signal Power switch on (IG), P position switch on 3 to 5 V
L5-17 (VCX4) - L5-6 (E1) SB - W-B Select sensor power source (VCX4) Power switch on (IG) 11 to 14 V
L5-18 (VSX4) - L5-6 (E1) BE - W-B Select sensor (Sub) Power switch on (IG), shift lever in home position or B 1.0 to 1.6 V
L5-18 (VSX4) - L5-6 (E1) BE - W-B Select sensor (Sub) Power switch on (IG), shift lever in R, N or D 2.9 to 4.3 V
L5-19 (VSX3) - L5-6 (E1) BR - W-B Select sensor (Main) Power switch on (IG), shift lever in home position or B 1.0 to 1.6 V
L5-19 (VSX3) - L5-6 (E1) BR - W-B Select sensor (Main) Power switch on (IG), shift lever in R, N or D 2.9 to 4.3 V
L5-20 (VCX2) - L5-22 (E2X2) Y - V Shift sensor power source (VSX2) Power switch on (IG) 4.5 to 5.5 V
L5-21 (VSX2) - L5-22 (E2X2) LG - V Shift sensor (Sub) Power switch on (IG), shift lever in home position or N 2.0 to 3.0 V
L5-21 (VSX2) - L5-22 (E2X2) LG - V Shift sensor (Sub) Power switch on (IG), shift lever in R 0.3 to 1.8 V
L5-21 (VSX2) - L5-22 (E2X2) LG - V Shift sensor (Sub) Power switch on (IG), shift lever in B or D 3.2 to 4.8 V
L5-24 (VSX1) - L5-23 (E2X1) L - SB Shift sensor (Main) Power switch on (IG), shift lever in home position or N 2.0 to 3.0 V
L5-24 (VSX1) - L5-23 (E2X1) L - SB Shift sensor (Main) Power switch on (IG), shift lever in R 0.3 to 1.8 V
L5-24 (VSX1) - L5-23 (E2X1) L - SB Shift sensor (Main) Power switch on (IG), shift lever in B or D 3.2 to 4.8 V
L5-25 (VCX1) - L5-23 (E2X1) P - SB Shift sensor power source (VSX1) Power switch on (IG) 4.5 to 5.5 V
L5-29 (VCX3) - L5-6 (E1) W - W-B Select sensor power source (VSX3) Power switch on (IG) 11 to 14 V
L5-32 (BTH+) - L5-6 (E1) R - W-B Communication signal from battery smart unit to hybrid vehicle control ECU Power switch on (IG) Pulse generation
(Waveform 11)
L5-33 (BTH-) - L5-6 (E1) G - W-B Communication signal from battery smart unit to hybrid vehicle control ECU Power switch on (IG) Pulse generation
(Waveform 11)
L5-34 (CA2H) - L5-6 (E1) B - W-B CAN communication signal Power switch on (IG) Pulse generation
(Waveform 12)
L5-35 (CA2L) - L5-6 (E1) G - W-B CAN communication signal Power switch on (IG) Pulse generation
(Waveform 12)
L6-3 (BATT) - L5-6 (E1) W - W-B Constant power source Always 10 to 14 V
L6-14 (ABFS) - L5-6 (E1) V - W-B Airbag activation signal Power switch on (READY) Pulse generation
(Waveform 13)
L6-15 (EVSW) - L5-6 (E1) B - W-B EV drive mode switch signal Power switch on (IG), EV drive mode switch not operated 11 to 14 V
L6-15 (EVSW) - L5-6 (E1) B - W-B EV drive mode switch signal Power switch on (IG), EV drive mode switch operated 0 to 1.5 V
L6-20 (THB) - L6-21 (ETHB) L - GR Auxiliary battery temperature Power switch on (IG), auxiliary battery temperature 25°C (77°F) 1.7 to 2.3 V
L6-20 (THB) - L6-21 (ETHB) L - GR Auxiliary battery temperature Power switch on (IG), auxiliary battery temperature 60°C (140°F) 0.6 to 0.9 V
L6-22 (IMI) - L5-6 (E1) LG - W-B Immobiliser communication signal Power switch off → Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 14)
L6-23 (IMO) - L5-6 (E1) SB - W-B Immobiliser communication signal Power switch off → Power switch on (IG) → Power switch on (READY) Pulse generation
(Waveform 14)
L6-24 (CA1L) - L5-6 (E1) P - W-B CAN communication signal Power switch on (IG) Pulse generation
(Waveform 15)
L6-25 (CA1H) - L5-6 (E1) V - W-B CAN communication signal Power switch on (IG) Pulse generation
(Waveform 15)
L6-28 (TC) - L5-6 (E1) P - W-B Diagnosis terminal Power switch on (IG)
L6-29 (SI0) - L5-6 (E1) Y - W-B HV battery blower fan operation signal Power switch on (IG), during Active Test Pulse generation
(Waveform 16)
L6-30 (CA3N) - L5-6 (E1) W - W-B CAN communication signal Power switch on (IG) Pulse generation
(Waveform 17)
L6-31 (CA3P) - L5-6 (E1) B - W-B CAN communication signal Power switch on (IG) Pulse generation
(Waveform 17)

*1: w/ Dynamic Radar Cruise Control

*2: w/o Dynamic Radar Cruise Control


Oscilloscope waveforms


HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


a.
A217984E01
2.799,1.114 3.141,1.290 0.342,0.177 10 GND

Waveform 1 (camshaft position sensor signal)

Item Content
Terminal A21-10 (GI) - L5-6 (E1)
Equipment Setting 5 V/DIV., 20 ms./DIV.
Condition Power switch on (READY), with engine running

HINT:

The pulse cycle becomes shorter as the engine speed increases.



b.
A415999E04
0.365,0.854 0.823,1.052 0.458,0.198 10 false CH1 0.375,1.417 0.833,1.615 0.458,0.198 10 false CH2 2.958,1.635 3.281,1.917 0.323,0.281 10 false GND 2.958,0.854 3.281,1.135 0.323,0.281 10 false GND

Waveform 2 (inverter water pump assembly signal)

Item Content
Terminal CH1: A21-13 (IWP) - L5-6 (E1)
CH2: A21-14 (NIWP) - L5-6 (E1)
Equipment Setting 5 V/DIV., 20 ms./DIV.
Condition Power switch on (READY)


c.
A217985E01
2.879,0.95 3.255,1.145 0.376,0.195 10 GND

Waveform 3(DC/DC operation monitor / voltage change signal)

Item Content
Terminal A21-16 (VLO) - L5-6 (E1)
Equipment Setting 5 V/DIV., 50 ms./DIV.
Condition Power switch on (IG)

HINT:

The cycle will vary depending on the specified voltage of the DC/DC converter.



d.
A379326E03
0.281,0.448 0.594,0.646 0.313,0.198 10 false CH1 0.281,0.865 0.594,1.063 0.313,0.198 10 false CH2 0.281,1.229 0.594,1.427 0.313,0.198 10 false CH3 0.292,1.646 0.604,1.844 0.313,0.198 10 false CH4 2.948,0.646 3.344,0.844 0.396,0.198 10 false GND 2.958,1 3.354,1.198 0.396,0.198 10 false GND 2.948,1.375 3.344,1.573 0.396,0.198 10 false GND 2.948,1.75 3.344,1.948 0.396,0.198 10 false GND

Waveform 4 (A/C communication signal)

Item Content
Terminal CH1: A22-10 (CLK) - L5-6 (E1)
CH2: A22-9 (ITE) - L5-6 (E1)
CH3: A22-8 (ETI) - L5-6 (E1)
CH4: A22-11 (STB) - L5-6 (E1)
Equipment Setting 10 V/DIV., 100 ms./DIV.
Condition Power switch on (READY), air conditioning system stopped

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



e.
A379254E03
0.208,0.646 0.594,0.865 0.385,0.219 10 false CH1 0.229,1.396 0.615,1.615 0.385,0.219 10 false CH2 2.833,1.01 3.219,1.229 0.385,0.219 10 false GND 2.844,1.563 3.229,1.781 0.385,0.219 10 false GND

Waveform 5 (communication signal from MG ECU to hybrid vehicle control ECU)

Item Content
Terminal CH1: A22-23 (MTH+) - L5-6 (E1)
CH2: A22-22 (MTH-) - L5-6 (E1)
Equipment Setting 1 V/DIV., 200 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



f.
A379254E03
0.208,0.646 0.594,0.865 0.385,0.219 10 false CH1 0.229,1.396 0.615,1.615 0.385,0.219 10 false CH2 2.833,1.01 3.219,1.229 0.385,0.219 10 false GND 2.844,1.563 3.229,1.781 0.385,0.219 10 false GND

Waveform 6 (communication signal from hybrid vehicle control ECU to MG ECU)

Item Content
Terminal CH1: A22-24 (HTM+) - L5-6 (E1)
CH2: A22-25 (HTM-) - L5-6 (E1)
Equipment Setting 1 V/DIV., 200 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



g.
A379252E03
0.344,0.625 0.688,0.854 0.344,0.229 10 false CH1 0.344,1.365 0.688,1.594 0.344,0.229 10 false CH2 2.938,1.01 3.281,1.24 0.344,0.229 10 false GND 2.938,1.563 3.281,1.792 0.344,0.229 10 false GND

Waveform 7 (MG ECU communication request signal)

Item Content
Terminal CH1: A22-31 (REQ+) - L5-6 (E1)
CH2: A22-30 (REQ-) - L5-6 (E1)
Equipment Setting 1 V/DIV., 1 ms./DIV.
Condition Power switch on (IG)


h.
U110381E01
2.914,1.077 2.779,1.077 false 2.914,1.644 2.779,1.644 false 2.949,0.991 3.306,1.147 0.357,0.156 10 GND 2.949,1.558 3.306,1.714 0.357,0.156 10 GND 0.225,0.656 0.548,0.825 0.323,0.170 10 CH1 0.225,1.326 0.548,1.496 0.323,0.170 10 CH2

Waveform 8 (MG communication clock signal)

Item Content
Terminal CH1: A22-33 (CLK+) - L5-6 (E1)
CH2: A22-32 (CLK-) - L5-6 (E1)
Equipment Setting 1 V/DIV., 1 μs./DIV.
Condition Power switch on (IG)


i.
C206010E21
2.958,0.625 3.292,0.865 0.333,0.24 10 false GND 2.958,1.031 3.292,1.271 0.333,0.24 10 false GND 2.958,1.438 3.292,1.677 0.333,0.24 10 false GND 0.198,0.635 0.531,0.875 0.333,0.24 10 false CH1 0.198,1.042 0.531,1.281 0.333,0.24 10 false CH2 0.198,1.448 0.531,1.688 0.333,0.24 10 false CH3

Waveform 9 (system main relay operation signal)

Item Content
Terminal CH1: L5-3 (SMRP) - L5-5 (E01)
CH2: L5-4 (SMRB) - L5-5 (E01)
CH3: L5-1 (SMRG) - L5-5 (E01)
Equipment Setting 10 V/DIV., 200 ms./DIV.
Condition Power switch on (IG) → Power switch on (READY)


j.
C351778E02
0.167,0.854 0.552,1.083 0.385,0.229 10 false CH1 0.188,1.469 0.573,1.698 0.385,0.229 10 false CH2 2.844,1.01 3.229,1.24 0.385,0.229 10 false GND 2.844,1.573 3.229,1.802 0.385,0.229 10 false GND

Waveform 10 (P position switch signal)

Item Content
Terminal CH1: L5-8 (PCON) - L5-6 (E1)
CH2: L5-15 (PPOS) - L5-6 (E1)
Equipment Setting 10 V/DIV., 10 ms./DIV.
Condition Power switch on (IG)


k.
A379330E03
2.948,1.01 3.406,1.208 0.458,0.198 10 false GND 2.948,1.563 3.406,1.76 0.458,0.198 10 false GND 0.188,0.625 0.646,0.823 0.458,0.198 10 false CH1 0.219,1.385 0.677,1.583 0.458,0.198 10 false CH2

Waveform 11 (communication signal from battery smart unit to hybrid vehicle control ECU)

Item Content
Terminal CH1: L5-32 (BTH+) - L5-6 (E1)
CH2: L5-33 (BTH-) - L5-6 (E1)
Equipment Setting 2 V/DIV., 500 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



l.
A379250E04
0.271,0.656 0.729,0.854 0.458,0.198 10 false CH1 0.271,1.313 0.729,1.51 0.458,0.198 10 false CH2 2.948,1.208 3.406,1.406 0.458,0.198 10 false GND 2.958,1.563 3.417,1.76 0.458,0.198 10 false GND

Waveform 12 (CAN communication signal)

Item Content
Terminal CH1: L5-34 (CA2H) - L5-6 (E1)
CH2: L5-35 (CA2L) - L5-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



m.
A379329E03
2.938,1.021 3.302,1.229 0.365,0.208 10 false GND

Waveform 13 (airbag activation signal)

Item Content
Terminal L6-14 (ABFS) - L5-6 (E1)
Equipment Setting 5 V/DIV., 500 ms./DIV.
Condition Power switch on (READY)


n.
A379331E02
0.219,0.646 0.531,0.844 0.313,0.198 10 false CH1 0.25,1.365 0.563,1.563 0.313,0.198 10 false CH2 2.948,1.042 3.344,1.229 0.396,0.188 10 false GND 2.938,1.573 3.333,1.76 0.396,0.188 10 false GND

Waveform 14 (immobiliser communication signal)

Item Content
Terminal CH1: L6-23 (IMO) - L5-6 (E1)
CH2: L6-22 (IMI) - L5-6 (E1)
Equipment Setting 5 V/DIV., 200 ms./DIV.
Condition Power switch off → Power switch on (IG) → Power switch on (READY)


o.
A379250E04
0.271,0.656 0.729,0.854 0.458,0.198 10 false CH1 0.271,1.313 0.729,1.51 0.458,0.198 10 false CH2 2.948,1.208 3.406,1.406 0.458,0.198 10 false GND 2.958,1.563 3.417,1.76 0.458,0.198 10 false GND

Waveform 15 (CAN communication signal)

Item Content
Terminal CH1: L6-25 (CA1H) - L5-6 (E1)
CH2: L6-24 (CA1L) - L5-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



p.
A379327E02
3.031,1.021 3.406,1.219 0.375,0.198 10 false GND

Waveform 16 (HV battery blower fan operation signal)

Item Content
Terminal L6-29 (SI0) - L5-6 (E1)
Equipment Setting 5 V/DIV., 500 ms./DIV.
Condition Power switch on (IG), during Active Test

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



q.
A379250E04
0.271,0.656 0.729,0.854 0.458,0.198 10 false CH1 0.271,1.313 0.729,1.51 0.458,0.198 10 false CH2 2.948,1.208 3.406,1.406 0.458,0.198 10 false GND 2.958,1.563 3.417,1.76 0.458,0.198 10 false GND

Waveform 17 (CAN communication signal)

Item Content
Terminal CH1: L6-31 (CA3P) - L5-6 (E1)
CH2: L6-30 (CA3N) - L5-6 (E1)
Equipment Setting 1 V/DIV., 50 μs./DIV.
Condition Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).




U154333E03
0.229,0.125 0.427,0.323 0.198,0.198 10 false *a 4.396,2.385 4.667,2.552 0.271,0.167 10 false D29 3.208,2.385 3.479,2.552 0.271,0.167 10 false A59

Text in Illustration
*a Component without harness connected
(Inverter with Converter Assembly)
- -

HINT:

Since the inverter with converter assembly uses waterproof connectors, the voltage and waveform cannot be inspected directly. Standard voltage readings and waveforms are indicated for reference only.


Inverter with converter assembly
Terminal No.
(Symbol)
Wiring Color Terminal Description Condition Standard Condition
A59-1 (IGCT) - A59-28 (GND1) B - W-B MG ECU power source Power switch on (IG) 11 to 14 V
A59-2 (IDH)*1 - A59-28 (GND1) L - W-B PTC heater prohibit signal Power switch on (IG) 4 to 6 V
A59-3 (VLO) - A59-28 (GND1) R - W-B DC/DC operation monitor / voltage change signal Power switch on (IG) Pulse generation
(Waveform 1)
A59-5 (CLK+) - A59-28 (GND1) B - W-B MG ECU communication clock signal Power switch on (READY) Pulse generation
(Waveform 2)
A59-6 (REQ+) - A59-28 (GND1) B - W-B MG ECU communication request signal Power switch on (READY) Pulse generation
(Waveform 3)
A59-7 (MTH+) - A59-28 (GND1) B - W-B Communication signal from MG ECU to hybrid vehicle control ECU Power switch on (READY) Pulse generation
(Waveform 4)
A59-8 (HTM+) - A59-28 (GND1) B - W-B Communication signal from hybrid vehicle control ECU to MG ECU Power switch on (READY) Pulse generation
(Waveform 5)
A59-11 (S) - A59-28 (GND1) W - W-B Auxiliary battery voltage monitor Power switch on (IG) 11 to 14 V
A59-12 (NODD) - A59-28 (GND1) W - W-B DC/DC operation DC/DC converter operating normally 5 to 7 V
A59-12 (NODD) - A59-28 (GND1) W - W-B DC/DC operation DC/DC converter not operating normally 2 to 4 V
A59-12 (NODD) - A59-28 (GND1) W - W-B DC/DC operation DC/DC converter operation prohibited 0.1 to 0.5 V
A59-15 (CLK-) - A59-28 (GND1) W - W-B MG ECU communication clock signal Power switch on (READY) Pulse generation
(Waveform 2)
A59-16 (REQ-) - A59-28 (GND1) W - W-B MG ECU communication request signal Power switch on (READY) Pulse generation
(Waveform 3)
A59-17 (MTH-) - A59-28 (GND1) W - W-B Communication signal from MG ECU to hybrid vehicle control ECU Power switch on (READY) Pulse generation
(Waveform 4)
A59-18 (HTM-) - A59-28 (GND1) W - W-B Communication signal from hybrid vehicle control ECU to MG ECU Power switch on (READY) Pulse generation
(Waveform 5)
A59-29 (GI) - A59-28 (GND1) B - W-B Camshaft position sensor signal Power switch on (READY), with engine running Pulse generation
(Waveform 6)
A59-31 (HSDN) - A59-28 (GND1) B - W-B MG shutdown signal Power switch on (READY) 0 to 1 V
A59-35 (ILKI) - A59-28 (GND1) V - W-B Interlock switch signal Power switch on (IG), inverter cover, high-voltage input cables and service plug grip installed correctly Below 1 V
A59-35 (ILKI) - A59-28 (GND1) V - W-B Interlock switch signal Power switch on (IG), inverter cover, high-voltage input cables or service plug grip not installed 11 to 14
A59-36 (ILKO) - A59-28 (GND1) LG - W-B Interlock switch signal Power switch on (IG), inverter cover, high-voltage input cables and service plug grip installed correctly Below 1 V
A59-36 (ILKO) - A59-28 (GND1) LG - W-B Interlock switch signal Power switch on (IG), inverter cover, high-voltage input cables or service plug grip not installed 11 to 14
A59-9 (+B2) - A59-28 (GND1) G - W-B MG ECU power source Power switch on (IG) 11 to 14 V
A59-10 (+B) - A59-28 (GND1) G - W-B MG ECU power source Power switch on (IG) 11 to 14 V
D29-1 (MRF) - D29-2 (MRFG) Y - L Motor resolver signal Motor resolver running Pulse generation
(Waveform 7)
D29-3 (MSN) - D29-4 (MSNG) G - W Motor resolver signal Motor resolver running Pulse generation
(Waveform 7)
D29-6 (MCS) - D29-5 (MCSG) R - BR Motor resolver signal Motor resolver running Pulse generation
(Waveform 7)
D29-7 (GSN) - D29-8 (GSNG) B - V Generator resolver signal Generator resolver running Pulse generation
(Waveform 8)
D29-10 (GCS) - D29-9 (GCSG) GR - LG Generator resolver signal Generator resolver running Pulse generation
(Waveform 8)
D29-11 (GRF) - D29-12 (GRFG) P - BE Generator resolver signal Generator resolver running Pulse generation
(Waveform 8)

*1: w/ PTC Heater


NOTICE:

Do not measure the voltage or waveform directly at the sealed side of the inverter with converter assembly connector. Doing so may damage the connector because the connector is waterproof.


Oscilloscope waveforms


HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


a.
A217985E01
2.879,0.95 3.255,1.145 0.376,0.195 10 GND

Waveform 1 (DC/DC operation monitor / voltage change signal)

Item Content
Terminal A59-3 (VLO) - A59-28 (GND1)
Equipment Setting 5 V/DIV., 50 ms./DIV.
Condition Power switch on (IG)

HINT:

The cycle will vary depending on the specified voltage of the DC/DC converter.



b.
A379251E03
0.25,0.625 0.708,0.823 0.458,0.198 10 false CH1 0.26,1.354 0.719,1.552 0.458,0.198 10 false CH2 2.948,1 3.406,1.198 0.458,0.198 10 false GND 2.938,1.573 3.396,1.771 0.458,0.198 10 false GND

Waveform 2 (MG ECU communication clock signal)

Item Content
Terminal CH1: A59-5 (CLK+) - A59-28 (GND1)
CH2: A59-15 (CLK-) - A59-28 (GND1)
Equipment Setting 1 V/DIV., 1 μs./DIV.
Condition Power switch on (READY)


c.
A379252E03
0.344,0.625 0.688,0.854 0.344,0.229 10 false CH1 0.344,1.365 0.688,1.594 0.344,0.229 10 false CH2 2.938,1.01 3.281,1.24 0.344,0.229 10 false GND 2.938,1.563 3.281,1.792 0.344,0.229 10 false GND

Waveform 3 (MG ECU communication request signal)

Item Content
Terminal CH1: A59-6 (REQ+) - A59-28 (GND1)
CH2: A59-16 (REQ-) - A59-28 (GND1)
Equipment Setting 1 V/DIV., 1 ms./DIV.
Condition Power switch on (READY)


d.
A379254E03
0.208,0.646 0.594,0.865 0.385,0.219 10 false CH1 0.229,1.396 0.615,1.615 0.385,0.219 10 false CH2 2.833,1.01 3.219,1.229 0.385,0.219 10 false GND 2.844,1.563 3.229,1.781 0.385,0.219 10 false GND

Waveform 4 (communication signal from MG ECU to hybrid vehicle control ECU)

Item Content
Terminal CH1: A59-7 (MTH+) - A59-28 (GND1)
CH2: A59-17 (MTH-) - A59-28 (GND1)
Equipment Setting 1 V/DIV., 200 μs./DIV.
Condition Power switch on (READY)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



e.
A379254E03
0.208,0.646 0.594,0.865 0.385,0.219 10 false CH1 0.229,1.396 0.615,1.615 0.385,0.219 10 false CH2 2.833,1.01 3.219,1.229 0.385,0.219 10 false GND 2.844,1.563 3.229,1.781 0.385,0.219 10 false GND

Waveform 5 (communication signal from hybrid vehicle control ECU to MG ECU)

Item Content
Terminal CH1: A59-8 (HTM+) - A59-28 (GND1)
CH2: A59-18 (HTM-) - A59-28 (GND1)
Equipment Setting 1 V/DIV., 200 μs./DIV.
Condition Power switch on (READY)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



f.
A217984E01
2.799,1.114 3.141,1.290 0.342,0.177 10 GND

Waveform 6 (camshaft position sensor signal)

Item Content
Terminal A59-29 (GI) - A59-28 (GND1)
Equipment Setting 5 V/DIV., 20 ms./DIV.
Condition Power switch on (READY), with engine running

HINT:

The pulse cycle becomes shorter as the engine speed increases.



g.
A379253E03
0.271,0.615 0.729,0.813 0.458,0.198 10 false CH1 0.26,1.125 0.719,1.323 0.458,0.198 10 false CH2 0.281,1.396 0.74,1.594 0.458,0.198 10 false CH3 1.208,1.646 1.667,1.844 0.458,0.198 10 false A 2.948,0.646 3.406,0.844 0.458,0.198 10 false GND 2.948,1.115 3.406,1.313 0.458,0.198 10 false GND 2.948,1.385 3.406,1.583 0.458,0.198 10 false GND

Waveform 7 (motor resolver signal)

Item Content
Terminal CH1: D29-1 (MRF) - D29-2 (MRFG)
CH2: D29-3 (MSN) - D29-4 (MSNG)
CH3: D29-6 (MCS) - D29-5 (MCSG)
Equipment Setting CH1: 10 V/DIV., 1 ms./DIV.
CH2, 3: 5 V/DIV., 1 ms./DIV.
Condition Motor resolver running

HINT:

Pulse cycle A becomes shorter as the rotor speed increases.



h.
A379253E03
0.271,0.615 0.729,0.813 0.458,0.198 10 false CH1 0.26,1.125 0.719,1.323 0.458,0.198 10 false CH2 0.281,1.396 0.74,1.594 0.458,0.198 10 false CH3 1.208,1.646 1.667,1.844 0.458,0.198 10 false A 2.948,0.646 3.406,0.844 0.458,0.198 10 false GND 2.948,1.115 3.406,1.313 0.458,0.198 10 false GND 2.948,1.385 3.406,1.583 0.458,0.198 10 false GND

Waveform 8 (generator resolver signal)

Item Content
Terminal CH1: D29-11 (GRF) - D29-12 (GRFG)
CH2: D29-7 (GSN) - D29-8 (GSNG)
CH3: D29-10 (GCS) - D29-9 (GCSG)
Equipment Setting CH1: 10 V/DIV., 1 ms./DIV.
CH2, 3: 5 V/DIV., 1 ms./DIV.
Condition Generator resolver running

HINT:

Pulse cycle A becomes shorter as the rotor speed increases.