Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2014.11–2015.08
RM2070E _51 Engine / Hybrid System _061906 HYBRID / BATTERY CONTROL _0301573 HYBRID CONTROL SYSTEM U

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:
·

Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obtained. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.

·

In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions in order to reach an overall judgment by comparing all the items in the Data List.



a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Data List.


d.

Check the results by referring to the following table.

HINT:
·

When reviewing Data List information, try to select only the specific Data List items related to the inspection being performed. If all items are selected when checking the Data List, the interval between updates for each item will be longer, resulting in delayed or incorrect data.

·

Using a custom list makes it possible to easily select smaller groups of related Data List items.

·

The following custom lists are available:

-

HV Battery

-

Electric Leakage

-

Boost/Lower Converter

-

High Voltage Charge

-

HV Transmission

-

Thermo Sensor

-

Auxiliary Battery

-

Drive Performance

-

Elec Shift Lever System




Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Engine Coolant Temp Engine coolant temperature/
Min.: -40°C (-40°F), Max.: 215°C (419°F)
Cold start→Fully warmed up:
Gradually rises
After warming up:
80 to 100°C (176 to 212°F)
-
Engine Revolution Engine speed/
Min.: 0 rpm, Max.: 16383 rpm
While idling after the engine is warmed up and inspection mode:
Approximately 900 rpm
While driving at a constant speed:
No significant fluctuation
-
Vehicle Spd Vehicle speed/
Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
Vehicle stopped:
0 km/h (0 mph)
While driving at a constant speed:
No significant fluctuation
-
Engine Run Time Elapsed time after starting engine/
Min.: 0 s, Max.: 65535 s
Elapsed time after starting engine After the power switch is turned on (READY), elapsed time from initial engine start until the power switch is turned off.
+B Auxiliary battery voltage/
Min.: 0.00 V, Max.: 65.53 V
Constant:
Auxiliary battery voltage 10.00 to 15.00 V
Auxiliary battery
Accel Pedal Pos #1 Accelerator pedal position sensor No. 1/
Min.: 0.0%, Max.: 100.0%
Accelerator pedal depressed:
Changes with accelerator pedal pressure
Accelerator pedal sensor assembly
Accel Pedal Pos #2 Accelerator pedal position sensor No. 2/
Min.: 0.0%, Max.: 100.0%
Accelerator pedal depressed:
Changes with accelerator pedal pressure
Accelerator pedal sensor assembly
Ambient Temperature Ambient air temperature/
Min.: -40°C (-40°F), Max.: 215°C (419°F)
Power switch on (IG):
Same as ambient air temperature
Ambient temperature sensor
Intake Air Temperature Intake air temperature/
Min.: -40°C (-40°F), Max.: 140°C (284°F)
Constant:
Same as ambient air temperature
-
DTC Clear Warm Up The number of times the engine is warmed up after clearing DTCs/
Min.: 0, Max.: 255
MIL OFF, engine coolant temperature increases from below 22°C (72°F) before starting the engine to above 70°C (158°F) after starting the engine:
Increases once
-
DTC Clear Run Distance Drive distance after clearing DTCs/
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
- -
DTC Clear Min Elapsed time after clearing DTCs/
Min.: 0 min, Max.: 65535 min
- -
MIL on Engine Run Time Driving time after a malfunction occurs/
Min.: 0 min, Max.: 65535 min
- -
MIL Status MIL status/
ON or OFF
MIL ON: ON Constant ON: Repair in accordance with detected DTCs
MIL on Run Distance Travel distance after a malfunction occurs/
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
- -
Model Code Model code ZVW4# -
Engine Code Engine code P410 -
ECU Code ECU code - -
Destination Destination W -
OBD Requirements OBD requirements E-OBD -
MAP Intake manifold pressure/
Min.: 0 kPa, Max.: 255 kPa
Power switch on (IG) or engine stopped:
Atmosphere pressure
Valued less than atmospheric pressure are indicated while the engine is running
Atmosphere Pressure Atmospheric pressure/
Min.: 0 kPa, Max.: 255 kPa
Constant:
Atmosphere pressure
-
Number of Emission DTC The number of emission DTCs - -
Ready Signal Power switch condition/
ON or OFF
Power switch on (READ):
ON
-
Motor(MG2) Revolution MG2 revolution/
Min.: -32768 rpm, Max.: 32767 rpm
While driving:
Varies depending on vehicle operating conditions
·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Motor(MG2) Torq MG2 torque/
Min.: -4096.00 Nm, Max.: 4095.87 Nm
While driving:
Varies depending on vehicle operating conditions
·

Power management control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


M(MG2) Trq Exec Val MG2 torque execution value/
Min.: -4096.00 Nm, Max.: 4095.87 Nm
After full-load acceleration with power switch on (READY) and engine stopped:
Less than +/-20% of MG2 torque
·

Power management control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Generator(MG1) Rev MG1 revolution/
Min.: -32768 rpm, Max.: 32767 rpm
During charge or discharge:
Varies depending on vehicle operating conditions
·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Generator(MG1) Torq MG1 torque/
Min.: -4096.00 Nm, Max.: 4095.87 Nm
During charge or discharge:
Varies depending on vehicle operating conditions
·

Power management control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


G(MG1) Trq Exec Val MG1 torque execution value/
Min.: -4096.00 Nm, Max.: 4095.87 Nm
One second after engine automatically starts with park (P) selected (Condition before engine start: Power switch on (READY), engine stopped, A/C fan speed high and headlights on):
Less than +/- 20% of MG1 torque
·

Power management control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Regenerative Brake Torq MG1 regenerative braking execution torque/
Min.: -4096.0 Nm, Max.: 4095.0 Nm
While braking:
Varies depending on vehicle operation conditions
·

Power management control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Rqst Regen Brake Torq Requested MG1 regenerative braking torque/
Min.: -4096.0 Nm, Max.: 4095.0 Nm
While braking:
Varies depending on vehicle operation conditions
·

Power management control ECU

·

Hybrid vehicle transaxle assembly

·

Inverter with converter assembly


Inverter Temp-(MG1) Generator inverter temperature/
Min.: 15°C (59°F), Max.: 150°C (302°F)
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15°C (59°F) to 35°C (95°F)
While driving at an ambient temperature of 25°C (77°F):
15°C (59°F) to 110°C (230°F)
Inverter with converter assembly
Inverter Temp-(MG2) Motor inverter temperature/
Min.: 15°C (59°F), Max.: 150°C (302°F)
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15°C (59°F) to 35°C (95°F)
While driving at an ambient temperature of 25°C (77°F):
15°C (59°F) to 110°C (230°F)
Inverter with converter assembly
Motor Temp No2 MG1 temperature/
Min.: -40°C (-40°F), Max.: 215°C (419°F)
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F)
While driving at an ambient temperature of 25°C (77°F):
25°C (77°F) to 100°C (212°F)
GMT terminal
Motor Temp No1 MG2 temperature/
Min.: -40°C (-40°F), Max.: 215°C (419°F)
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F)
While driving at an ambient temperature of 25°C (77°F):
25°C (77°F) to 90°C (194°F)
MMT terminal
Accelerator Degree Accelerator pedal depressed angle/
Min.: 0.0%, Max.: 127.5%
Accelerator pedal depressed:
Changes with accelerator pedal pressure
Accelerator pedal sensor assembly
Request Power Request engine power/
Min.: 0 W, Max.: 655350 W
While driving with the engine running:
Varies depending on vehicle operating conditions
·

Power management control ECU

·

ECM

·

Engine


Target Engine Rev Target engine speed/
Min.: 0 rpm, Max.: 65535 rpm
While driving with the engine running:
Varies depending on vehicle operating conditions
·

Power management control ECU

·

ECM

·

Engine


Engine Rev (Sensor) Engine speed/
Min.: 0 rpm, Max.: 16383 rpm
While idling after the engine is warmed up:
Approximately 1000 rpm
While driving at a constant speed:
No significant fluctuation
-
State of Charge (All Bat) HV battery state of charge/
Min.: 0.0%, Max.: 100.0%
Constant:
0.0 to 80.0%
·

HV battery

·

Battery smart unit

·

Power management control ECU


Master Cylinder Ctrl Trq Master cylinder control torque/
Min.: -4096.0 Nm, Max.: 4095.0 Nm
Brake pedal depressed:
Changes with the brake pedal pressure
Master cylinder pressure sensor
Power Resource VB HV battery voltage/
Min.: 0.0 V, Max.: 6553.5 V
Power switch on (READY):
150.0 to 300.0 V
·

HV battery

·

Battery smart unit

·

Power management control ECU


Power Resource IB HV battery current/
Min.: -327.68 A, Max.: 327.67 A
Power switch on (READY):
-200.00 to 200.00 A
·

HV battery

·

Power cable

·

Inverter with converter assembly

·

Battery current sensor

·

Air conditioning system


Bat1 Pwr Resourc IB Sens2 HV battery current/
Min.: -327.68 A, Max.: 327.67 A
Power switch on (READY):
-150.00 to 190.00 A
·

HV battery

·

Power cable

·

Inverter with converter assembly

·

Battery current sensor

·

Air conditioning system


Power Supply Sensor Voltage Power supply sensor voltage (VC)/
Min.: 0.00 V, Max.: 79.99 V
Power switch on (IG):
4.00 to 6.00 V
-
VL-Voltage before Boosting High voltage before it is boosted/
Min.: 0 V, Max.: 360 V
Power switch on (READY):
Practically the same as the HV battery voltage
·

HV battery

·

Inverter with converter assembly


VH-Voltage after Boosting High voltage after it is boosted/
Min.: 0 V, Max.: 1000 V
Engine revving up with park (P) selected:
After boosted voltage to below 650 V
Inverter with converter assembly
Boost Ratio Boost converter boost ratio/
Min.: 0.0%, Max.: 127.5%
The pre-boost and the post boost voltages are equal:
0.0 to 10.0%
Inverter with converter assembly
Drive Condition ID Drive condition ID

Engine stopped: 0

Engine about to be stopped: 1

Engine about to be started: 2

Engine operated or operating: 3


·

Power management control ECU

·

ECM

·

Hybrid vehicle transaxle assembly


Shift Sensor Main Shift sensor (Main) voltage/
Min.: 0.00 V, Max.: 4.98 V
Shift lever in home position or shift lever in N:
2.00 to 3.00 V
Shift lever in R:
0.30 to 1.80 V
Shift lever in D or B:
3.20 to 4.80 V
-
Shift Sensor Sub Shift sensor (Sub) voltage/
Min.: 0.00 V, Max.: 4.98 V
Shift lever in home position or shift lever in N:
2.00 to 3.00 V
Shift lever in R:
0.30 to 1.80 V
Shift lever in D or B:
3.20 to 4.80 V
-
Shift Sensor Select Main Select sensor (Main) voltage/
Min.: 0.00 V, Max.: 4.98 V
Shift lever in home position or shift lever in B:
1.00 to 1.60 V
Shift lever in R, N or D:
2.90 to 4.30 V
-
Shift Sensor Select Sub Select sensor (Sub) voltage/
Min.: 0.00 V, Max.: 4.98 V
Shift lever in home position or shift lever in B:
1.00 to 1.60 V
Shift lever in R, N or D:
2.90 to 4.30 V
-
Shift Sensor Shift Pos Shift position/
P/R/N/D/B
Matches currently selected shift position:
P, R, N, D or B
Shift lever position sensor
Crank Position Crankshaft position/
Min.: -128 °CA, Max.: 127 °CA
- -
A/C Consumption Pwr A/C consumption power/
Min.: 0 W, Max.: 12750 W
While the air conditioning system is operating: 0.001 kW to 5000 W Air conditioning system
Short Wave Highest Val Waveform voltage in leak detection circuit in battery smart unit/
Min.: 0.00 V, Max.: 4.98 V
Left for 2 minutes in power switch on (READY), and pre-boost and post boost voltages are equal:
4.00 V or more
High voltage circuit
MG1 Control Mode MG1 control mode/
Min.: 0, Max.: 2
PWM: 0
Variable PWM: 1
Rectangular wave: 2
-
MG1 Carrier Frequency MG1 carrier frequency/
0.75kHz/1.25kHz/2.50kHz/3.75kHz/5.00kHz/10.00kHz
- -
MG2 Control Mode MG2 control mode/
Min.: 0, Max.: 2
PWM: 0
Variable PWM: 1
Rectangular wave: 2
-
MG2 Carrier Frequency MG2 carrier frequency/
0.75kHz/1.25kHz/2.50kHz/3.75kHz/5.00kHz
- -
Num of Current Code The number of current DTCs/
Min.: 0, Max.: 255
- -
Num of History Code The number of history DTCs/
Min.: 0, Max.: 255
- -
Check Mode Check Mode/
ON or OFF
- -
Calculate Load Calculated load/
Min.: 0.0%, Max.: 100.0%
Engine idling with warm engine, air conditioner off, park (P) and inspection mode selected:
20.0 to 40.0%
Engine speed of 2500 rpm, air conditioner off, park (P) and inspection mode selected:
15.0 to 35.0%
·

Air cleaner condition

·

Throttle valve status


Throttle Position Throttle position sensor/
Min.: 0.0%, Max.: 100.0%
Throttle valve fully closed:
10.0 to 24.0%
Throttle valve status
DCDC Cnv Tar Pulse Duty Target auxiliary battery voltage/
Min.: 0.0%, Max.: 399.9%
- -
Inverter Coolant Water Temperature Inverter coolant temperature/
Min.: -40°C (-40°F), Max.: 110°C (230°F)
Cold start→Fully warmed up:
Gradually rises
System operating normally:
Controlled at 65°C (149°F) or less
·

Inverter with converter assembly

·

Inverter water pump assembly

·

Cooling fan system

·

Inverter cooling system

·

IGCT No. 3 fuse


Cooling Fan 0 Cooling fan operating condition/
Min.: 0.0%, Max.: 127.5%
- -
Cooling Fan Relay BATT FAN relay/
ON or OFF
While the battery cooling fan is operating:
ON
-
Inverter W/P Revolution Inverter water pump assembly speed/
Min.: 0 rpm, Max.: 15000 rpm
Power switch on (READY):
1375 to 5500 rpm
·

Power management control ECU

·

Inverter water pump assembly


Prohibit DC/DC conv sig DC/DC converter prohibition signal/
ON or OFF
Power switch on (IG):
ON (Prohibited)
Power switch on (READY):
OFF (Permitted)
·

Power management control ECU

·

DC/DC converter


EV Request EV drive mode transition availability/
ON or OFF
In EV drive mode:
ON
-
TRC OFF Switch VSC OFF switch condition/
OFF / TRC / TRC/VSC
- -
Starter Switch Starter ON / OFF signal/
ON or OFF
- -
Inv-T (MG1) aftr IG-ON Generator inverter temperature soon after power switch on (IG)/
Min.: 15°C (59°F), Max.: 150°C (302°F)
- -
Inv-T (MG2) aftr IG-ON Motor inverter temperature soon after power switch on (IG)/
Min.: 15°C (59°F), Max.: 150°C (302°F)
- -
Mtr-T (MG2) aftr IG-ON MG2 temperature soon after power switch on (IG)/
Min.: -40°C (-40°F), Max.: 215°C (419°F)
- -
Conv-Tmp after IG-ON Boost converter temperature soon after power switch on (IG)/
Min.: 15°C (59°F), Max.: 150°C (302°F)
- -
SOC after IG-ON HV battery state of charge soon after power switch on (IG)/
Min.: 0.0%, Max.: 127.5%
- -
Inv-Temp (MG1) Max Generator inverter maximum temperature/
Min.: 15°C (59°F), Max.: 150°C (302°F)
- -
Inv-Temp (MG2) Max Motor inverter maximum temperature/
Min.: 15°C (59°F), Max.: 150°C (302°F)
- -
Mtr-Temp (MG2) Max MG2 maximum temperature/
Min.: -40°C (-40°F), Max.: 215°C (419°F)
- -
Converter Temp Max Boost converter maximum temperature/
Min.: 15°C(59°F), Max.: 150°C (302°F)
- -
Status of Charge Max Maximum status of charge/
Min.: 0.0%, Max.: 127.5%
- -
Status of Charge Min Minimum status of charge/
Min.: 0.0%, Max.: 127.5%
- -
Stop Light Switch Stop light switch condition/
ON or OFF
Brake pedal depressed:
ON
-
Auxiliary Batt Temperature Auxiliary battery temperature/
Min.: -40°C (-40°F), Max.: 215°C (419°F)
Auxiliary battery temperature is 20°C (68°F):
20°C (68°F)
-
Collision Signal (Airbag) Detection of collision by airbag ECU assembly/
ON or OFF
Collision detection by the airbag ECU assembly:
ON
-
TC Terminal TC terminal state/
ON or OFF
TC terminal connected:
ON
-
Inter Lock Switch Interlock switch condition/
ON or OFF
Power switch on (IG), inverter cover, high voltage input cables and service plug grip installed detached:
ON
-
EV Switch EV drive mode switch (combination switch assembly) condition/
ON or OFF
EV drive mode switch (combination switch assembly) being pushed and held:
ON
-
Back Up Lamp Relay Back up light switch condition/
ON or OFF
Shift lever in R
ON
-
ECO Mode ECO drive mode transition availability/
ON or OFF
In ECO drive mode:
ON
·

Combination meter sub-assembly

·

Power management control ECU


Generate Torque Generated drive torque/
Min.: -4096.0 Nm, Max.: 4095.8 Nm
While driving:
Varies depending on vehicle operating conditions
-
Prohibit Charge for P Pos HV battery charge in park (P) selected prohibition state/
ON or OFF
HV battery charge in park (P) selected prohibition:
ON
-
Battery Status Light Request Indicates the illumination status of the hybrid battery indicator light/
OFF / ON (Valve Check) / ON (Batt Diagnosis Request) / Blink (Diagnosing Batt) / Fast Blink (Nonusable Batt) / Blink + Buzzer (Batt Diagnosis Re-request) / ON (Starting Prohibited)
- -
Vehicle Parking (T/M Ctrl) Indicates whether vehicle being driven or stopped/
ON or OFF
- -
Shift Pos Status (T/M Ctrl) Indicates whether park (P) is selected/
Not P / Run / P
- -
Shift P Permission Signal Indicates whether selection of park (P) is permitted/
ON or OFF
- -
DC/DC Cnv Temp (Upper) Boost converter temperature (upper)/
Min.: 15°C (59°F), Max.: 150°C (302°F)
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15°C (59°F) to 35°C (95°F)
While driving at an ambient temperature of 25°C (77°F):
15°C (59°F) to 110°C (230°F)
Inverter with converter assembly
Safing Signal (Airbag) Safing state of the airbag ECU assembly/
ON or OFF
When safing state of the airbag ECU assembly:
ON
-
DC/DC Cnv Temp (Lower) Boost converter temperature (lower)/
Min.: 15°C (59°F), Max.: 150°C (302°F)
Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15°C (59°F) to 35°C (95°F)
While driving at an ambient temperature of 25°C (77°F):
15°C (59°F) to 121°C (250°F)
Inverter with converter assembly
Normal Signal for A/B ECU Control state of airbag ECU assembly/
ON or OFF
When the airbag ECU assembly is operating normally:
ON
-
Mtr-T (MG1) aftr IG-ON MG1 temperature soon after power switch on (IG)/
Min.: -40°C (-40°F), Max.: 215°C (419°F)
- -
Mtr-Temp (MG1) Max MG1 maximum temperature/
Min.: -40°C (-40°F), Max.: 215°C (419°F)
- -
Overvoltage Input to Conv Boost converter overvoltage detection/
ON or OFF
Overvoltage is received by the boost converter:
ON
Normal:
OFF
-
Overvoltage Input to Inv Inverter overvoltage detection/
ON or OFF
Overvoltage is received by the inverter:
ON
Normal:
OFF
-
Emergency Shutdown Inverter emergency shutdown/
ON or OFF
Inverter emergency shutdown:
ON
Normal:
OFF
-
MG1 Inverter Shutdown Generator inverter shutdown/
ON or OFF
Generator inverter shutdown:
ON
Normal:
OFF
-
MG1 Inverter Fail Generator inverter failure/
ON or OFF
Generator inverter faulty:
ON
Normal:
OFF
-
MG2 Inverter Shutdown Motor inverter shutdown/
ON or OFF
Motor inverter shutdown:
ON
Normal:
OFF
-
MG2 Inverter Fail Motor inverter failure/
ON or OFF
Motor inverter faulty:
ON
Normal:
OFF
-
Conv Shutdown Boost converter shutdown/
ON or OFF
Boost converter shutdown:
ON
Normal:
OFF
-
Converter Fail Boost converter failure/
ON or OFF
Boost converter faulty:
ON
Normal:
OFF
-
P Pos SW Terminal Vol Indicates voltage at the P position switch terminals/
Min.: 0.00 V, Max.: 4.98 V
P position switch ON:
0.00 to 1.50 V
-
Internal Shift Position ECU internal shift condition/
P/R/N/D/B
Matches currently selected shift position:
P, R, N, D or B
-
P Rq Malfunction (T/M Ctrl) Indicates whether park (P) selection request is normal/
Normal or Abnormal
- -
P Request (T/M Ctrl) Indicates whether selection of park (P) is requested/
ON or OFF
- -
T/M Control ECU Status Indicates the control condition of the transmission control ECU/
Normal or Abnormal
- -
T/M ECU Pulse Consec Err Indicates consecutive communication errors with the transmission control ECU/
Normal or Abnormal
- -
T/M ECU Pulse Single Err Indicates a single communication error with the transmission control ECU/
Normal or Abnormal
- -
HV Start Condition Indicates the hybrid start condition/
Norml / Pr A/C / Remote
- -
W/P Run Control Duty Inverter water pump motor driver request duty/
Min.: 0.00%, Max.: 100.00%
Power switch on (READY):
62.50 to 81.25%
Power management control ECU
Engine Stop Request Engine stop request/
Request or No
Requesting engine stop:
Request
·

ECM

·

Power management control ECU


Engine Idling Request Engine idling request/
Request or No
Requesting idle:
Request
·

ECM

·

Power management control ECU


Main Batt Charging Rqst HV battery charging request/
Request or No
Requesting HV battery charging:
Request
·

Battery smart unit

·

HV battery


Aircon Request Engine starting request from A/C amplifier/
Request or No
While an engine start is requested from the A/C amplifier:
Request
Air conditioning amplifier
Engine Warming Up Rqst Engine warm-up request/
Request or No
While an engine warm-up is requested:
Request
After the engine is warmed up:
No
·

Power management control ECU

·

ECM


SMRP Status Operating state of SMRP/
ON or OFF
Immediately after the power switch on (ST-ON) state occurred:
ON
After the above timing:
OFF
Cannot be confirmed using the GTS. Use an oscilloscope.
·

Hybrid battery junction block assembly

·

Wire harness


SMRB Status Operating state of SMRB/
ON or OFF
Power switch on (READY):
ON
·

Hybrid battery junction block assembly

·

Wire harness


SMRG Status Operating state of SMRG/
ON or OFF
Power switch on (READY):
ON
·

Hybrid battery junction block assembly

·

Wire harness


SMRP Control Status Commanded state of SMRP/
ON or OFF
Immediately after the power switch on (ST-ON) state occurred:
ON
After the above timing:
OFF
Cannot be confirmed using the GTS. Use an oscilloscope.
·

Hybrid battery junction block assembly

·

Wire harness


SMRB Control Status Commanded state of SMRB/
ON or OFF
Power switch on (READY):
ON
·

Hybrid battery junction block assembly

·

Wire harness


SMRG Control Status Commanded state of SMRG/
ON or OFF
Power switch on (READY):
ON
·

Hybrid battery junction block assembly

·

Wire harness


MG1 Gate Status MG1 gate status/
ON or OFF
Shutting down generator inverter:
ON
Normal:
OFF
·

Power management control ECU

·

Inverter with converter assembly


MG2 Gate Status MG2 gate status/
ON or OFF
Shutting down motor inverter:
ON
Normal:
OFF
·

Power management control ECU

·

Inverter with converter assembly


Converter Gate Status Boost converter gate status/
ON or OFF
Shutting down boost converter:
ON
Normal:
OFF
·

Power management control ECU

·

Inverter with converter assembly


Aircon Gate Status While A/C inverter is being shut off/
ON or OFF
While A/C inverter is being shut off:
ON
Normal:
OFF
·

Air conditioning amplifier

·

Power management control ECU


Converter Carrier Freq Boost converter signal carrier frequency/
9.55kHz/9.13kHz/8.71kHz/8.29kHz/7.87kHz/7.45kHz/4.8kHz
- -
Delta SOC Difference between maximum and minimum values of SOC/
Min.: 0.0%, Max.: 127.5%
READY indicator on, engine stopped and no electrical load:
0.0 to 30.0%
-
Batt Pack Current Val HV battery current/
Min.: -327.68 A, Max.: 327.67 A
Immediately after a full-load acceleration with the engine stopped:
Maximum 190.00 A
Immediately after engine start with park (P) selected:
100.00 A or more
HV battery current sensor circuit
Bat No. 1 Sens No. 2 Cur Val HV battery current/
Min.: -327.68 A, Max.: 327.67 A
- HV battery current sensor circuit
Inhaling Air Temp HV battery intake air temperature/
Min.: -50°C (-58°F), Max.: 205.9°C (402.6°F)
- -
Inhaling Air Temp 2 HV battery intake air temperature/
Min.: -50°C (-58°F), Max.: 205.9°C (402.6°F)
- -
VMF Fan Motor Voltage1 Battery cooling blower motor monitoring voltage/
Min.: 0.0 V, Max.: 25.5 V
Fan mode 1 with READY indicator ON and park (P) selected:
1.0 to 1.4 V
Battery cooling fan circuit
Auxiliary Battery Vol Auxiliary battery voltage/
Min.: -40.00 V, Max.: 39.90 V
Same as auxiliary battery voltage
·

Auxiliary battery

·

DC/DC converter


Charge Control Value Charge control wattage sent from battery smart unit to power management control ECU/
Min.: -64.0 kW, Max.: 63.5 kW
-33.0 kW or more -
Discharge Control Value Discharge control wattage sent from battery smart unit to power management control ECU/
Min.: -64.0 kW, Max.: 63.5 kW
40.0 kW or less -
Cooling Fan Mode1 Battery cooling fan operation mode/
Min.: 0, Max.: 6
Power switch on (IG) or on (READY), and cooling fan stopped:
0
Power switch on (IG) or on (READY), and cooling fan low speed to high speed:
1→6
Battery cooling fan circuit
ECU Control Mode HV battery control mode/
Min.: 0, Max.: 4
Driving control mode:
0
Current sensor offset mode:
1
External charge control mode:
2
Power supply end mode:
3
-
Standby Blower Request Battery cooling fan Lo speed requested/
ON or OFF
Constant:
ON or OFF
Air conditioning system
Temp of Batt TB1 Battery module temperature/
Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)
Undisturbed for 1 day:
Same as ambient air temperature
·

Battery temperature sensor

·

Battery smart unit


Temp of Batt TB2 Battery module temperature/
Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)
Undisturbed for 1 day:
Same as ambient air temperature
·

Battery temperature sensor

·

Battery smart unit


Temp of Batt TB3 Battery module temperature/
Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)
Undisturbed for 1 day:
Same as ambient air temperature
·

Battery temperature sensor

·

Battery smart unit


Temp of Batt TB4 Battery module temperature/
Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)
Undisturbed for 1 day:
Same as ambient air temperature
·

Battery temperature sensor

·

Battery smart unit


Temp of Batt TB5 Battery module temperature/
Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)
Undisturbed for 1 day:
Same as ambient air temperature
·

Battery temperature sensor

·

Battery smart unit


Temp of Batt TB6 Battery module temperature/
Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F)
Undisturbed for 1 day:
Same as ambient air temperature
·

Battery temperature sensor

·

Battery smart unit


Battery Block Num The number of battery blocks Always: 8 HV battery
Batt Block Minimum Vol Battery block minimum voltage/
Min.: 0.00 V, Max.: 79.99 V
SOC 40.00 to 80.00%:
21.00 to 28.00 V
-
Minimum Batt Block No Battery block number with minimum voltage/
Min.: 0, Max.: 8
Any of block number 0 to 8 -
Batt Block Max Vol Battery block maximum voltage/
Min.: 0.00 V, Max.: 79.99 V
SOC 40.00 to 80.00%:
28.00 V or less
-
Max Battery Block No Battery block number with maximum voltage/
Min.: 0, Max.: 8
Any of block number 0 to 8 -
Battery Block Vol -V01 Battery block voltage/
Min.: 0.00 V, Max.: 79.99 V
SOC 60.00% :
21.00 to 28.00 V
·

HV battery

·

Battery smart unit


Battery Block Vol -V02 Battery block voltage/
Min.: 0.00 V, Max.: 79.99 V
SOC 60.00% :
21.00 to 28.00 V
·

HV battery

·

Battery smart unit


Battery Block Vol -V03 Battery block voltage/
Min.: 0.00 V, Max.: 79.99 V
SOC 60.00% :
21.00 to 28.00 V
·

HV battery

·

Battery smart unit


Battery Block Vol -V04 Battery block voltage/
Min.: 0.00 V, Max.: 79.99 V
SOC 60.00% :
21.00 to 28.00 V
·

HV battery

·

Battery smart unit


Battery Block Vol -V05 Battery block voltage/
Min.: 0.00 V, Max.: 79.99 V
SOC 60.00% :
21.00 to 28.00 V
·

HV battery

·

Battery smart unit


Battery Block Vol -V06 Battery block voltage/
Min.: 0.00 V, Max.: 79.99 V
SOC 60.00% :
21.00 to 28.00 V
·

HV battery

·

Battery smart unit


Battery Block Vol -V07 Battery block voltage/
Min.: 0.00 V, Max.: 79.99 V
SOC 60.00% :
21.00 to 28.00 V
·

HV battery

·

Battery smart unit


Battery Block Vol -V08 Battery block voltage/
Min.: 0.00 V, Max.: 79.99 V
SOC 60.00% :
21.00 to 28.00 V
·

HV battery

·

Battery smart unit


Internal Resistance R01 Internal resistance of each battery block/
Min.: 0.000 Ω, Max.: 0.255 Ω
Always:
0.010 to 0.100 Ω
HV battery
Internal Resistance R02 Internal resistance of each battery block/
Min.: 0.000 Ω, Max.: 0.255 Ω
Always:
0.010 to 0.100 Ω
HV battery
Internal Resistance R03 Internal resistance of each battery block/
Min.: 0.000 Ω, Max.: 0.255 Ω
Always:
0.010 to 0.100 Ω
HV battery
Internal Resistance R04 Internal resistance of each battery block/
Min.: 0.000 Ω, Max.: 0.255 Ω
Always:
0.010 to 0.100 Ω
HV battery
Internal Resistance R05 Internal resistance of each battery block/
Min.: 0.000 Ω, Max.: 0.255 Ω
Always:
0.010 to 0.100 Ω
HV battery
Internal Resistance R06 Internal resistance of each battery block/
Min.: 0.000 Ω, Max.: 0.255 Ω
Always:
0.010 to 0.100 Ω
HV battery
Internal Resistance R07 Internal resistance of each battery block/
Min.: 0.000 Ω, Max.: 0.255 Ω
Always:
0.010 to 0.100 Ω
HV battery
Internal Resistance R08 Internal resistance of each battery block/
Min.: 0.000 Ω, Max.: 0.255 Ω
Always:
0.010 to 0.100 Ω
HV battery
Battery Low Time Cumulative total of extremely low HV battery charge level (engine not startable)/
Min.: 0, Max.: 65535
- -
DC Inhibit Time Cumulative total of extremely low HV battery charge level (engine startable)/
Min.: 0, Max.: 65535
- -
Battery too High Time Cumulative total of charging during charge prohibition state/
Min.: 0, Max.: 65535
- -
Hot Temperature Time Cumulative total of rapid HV battery temperature increase/
Min.: 0, Max.: 65535
- -
PM ECU -Batt Line1 Volt Indicates SOC signal/
Lo or Hi
- Normal:
"PM ECU -Batt Line1 Volt": Lo, "PM ECU -Batt Line2 Volt": Lo
or
"PM ECU -Batt Line1 Volt": Hi, "PM ECU -Batt Line2 Volt": Hi
PM ECU -Batt Line2 Volt Indicates SOC signal/
Lo or Hi
-
Cell High Voltage (LV1) HV Battery Cell High Voltage/
ON or OFF
- -
Cell High Voltage (LV2) HV Battery Cell High Voltage/
ON or OFF
- -
Cell Low Voltage (LV1) HV Battery Cell Low Voltage/
ON or OFF
- -
Cell Discharge Low HV Battery Cell Low Voltage/
ON or OFF
- -
Cell Discharge High HV Battery Cell Low Voltage/
ON or OFF
- -
Pattern Switch (PWR/M) POWER mode transition availability/
ON or OFF
In POWER mode:
ON
-



ACTIVE TEST


Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data list information can be displayed while performing Active Tests.

NOTICE:

It is necessary to use caution, because if the tester DLC connector becomes disconnected or if a communication error occurs during an Active Test, the vehicle could become inoperative (the READY indicator may go off).


a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.

Enter the following menus: Powertrain / Hybrid Control / Active Test.


d.

According to the display on the GTS perform the appropriate Active Test.

Tester Display Test Part Control Range Test Details Test Condition
Inspection Mode -2WD Inspection*1 - - - -
Inspection Mode -2WD Chassis-Dynamo*1 - - - -
Battery Charge To charge the HV battery using the THS charger - Allows current to flow into the HV battery by operating the SMRS Power switch on (IG), park (P) selected, and other Active Tests not being performed
Compression Test*2 To crank the engine continuously in order to measure the compression ON / OFF Allows the engine to continue cranking by activating MG1 continuously Power switch on (IG), HV system normal, not in cranking mode, and other Active Tests not being done
Activate the Water Pump To activate the inverter water pump assembly continuously ON / OFF Activates the inverter water pump assembly continuously Power switch on (IG), HV system normal, not in inspection mode, and other Active Tests not being done
Driving the Battery Cooling Fan To check operation of the cooling fan, and check if there is sufficient air flow 1 to 6 Stops the cooling fan or changes air volume mode -
Connect the TC and TE1 Batch display of warnings on combination meter ON / OFF TC terminal can be switched ON/OFF Power switch on (IG), system is normal

NOTICE:
·

*2: The GTS will display a communication error and the vehicle's READY indicator will turn off when the Active Test is completed. If the GTS will be used on the vehicle again, turn the power switch off and then on (READY) again to restart the GTS.